BR: Butadiene rubber

EM

Elastomers

General Properties

Short Name:

Name: 

BR

Butadiene rubber


BR stands for “butadiene rubber” and designates, along with SBR (styrene butadiene rubber), the most commonly used synthetic rubber. BR is produced from 1,3-butadiene. The monomers can be connected on both ends (1,4 bonding) or only on one end (1,2 bonding, vinyl group in the side chain) producing diff erent BR types with different properties. The 1,4 bonding can further be classified into 1,4 cis and 1,4 trans, where “cis“ means that the substituents are on the same side of the double bond; “trans” means they are on the opposite side of the double bond.

Structural Formula


Properties

Glass Transition Temperature-106 to -95 (1.4 cis), -107 to -83 (1,4 trans), -15 (1,2)°C
Melting Temperature-25 to 12 (1,4 cis), 97 / 145 (1,4 trans), 126 (1,2)°C
Melting Enthalpy46/170 (1,4 cis), 70 to 140 (1,4 trans) J/g
Decomposition Temperature370 to 385 / 460 to 475°C
Young's Modulus-
Coefficient of Linear Thermal Expansion-
Specific Heat Capacity1.76 to 1.96 J/(g*K)
Thermal Conductivity0.25 W/(m*K)
Density0.9 to 1.0 g/cm³
MorphologyElastomer with hard and soft segments
General propertiesHigh elasticity. High stability. High abrasion resistance
ProcessingExtrusion, calendering, injection molding, vulcanization
ApplicationsTire industry (blends with NR or SBR). Mechanical engineering. Technical rubber goods (e.g., band conveyors). Golf balls, shoe soles

NETZSCH Measurement

InstrumentDSC 204 F1 Phoenix®
Sample Mass12.29 mg
Isothermal Phase8 min / 3 min / 8 min
Heating/Colling Rates10 K/min
CrucibleAl, pierced lid
AtmosphereN2 (40 ml/min)

Evaluation

Polybutadiene or butadiene rubber has both soft and hard segments. For this reason, the above graphic shows a glass transition at -101°C (midpoint) in both heatings with a step height (Δcp) of approx. 0.27 J/(g.K) from the soft segments and a melting EndothermEin Phasenübergang oder eine Reaktion ist endotherm, wenn für die Umwandlung Wärme benötigt wird.endotherm with a peak temperature of -5°C from the hard segments. It can be concluded that the sample is mainly a 1,4 cis type.