Advanced thermal analysis instruments, TMA 512 *Hyperion®* and DIL 502 *Expedis®*, showcasing precision and versatility for material testing.

Introducing the Next Generation of Thermal Expansion Measurement Experts:

The new TMA 512 Hyperion® and the DIL 502 Expedis®

Engineered for excellence: The LFA 717 HyperFlash® Series

Discover the latest breakthroughs in measuring linear thermal expansion with the all-new TMA 512 Hyperion® and DIL 502 Expedis® Series. These state-of-the-art instruments provide the accuracy, versatility, and insight you need to optimize your materials and processes, whether you are developing advanced polymers, ceramics, metals, or composites.

TMA 512 Hyperion®® – Maximum Versatility, Minimal Effort

Engineered for ultimate flexibility, the TMA 512 Hyperion® Series allows you to investigate dimensional changes under real-world conditions. Key features include:

  • Ultra-Precise Length Detection
    The proven LVDT technology enables length changes to be measured down to the nanometre range, with a resolution of 0.125 nm.
  • Intuitive monitoring
    The LED status bar and touch display allow for easy, at-a-glance control of the instrument and measurement start.
  • Broad Temperature Range and Flexible Temperature and Atmospheres
    Easily interchangeable furnaces cover temperatures from -150°C to 1600°C and support various atmospheres, such as inert, oxidizing, reducing, vacuum, humidity, water vapor, and hydrogen. The dual furnace version enables quick switching in minutes.
  • IntroducingH₂Secureto TMA — the ultimate safety solution for hydrogen testing
    NETZSCH 'sH₂Secureconcept provides a comprehensive and secure solution for testing at different hydrogen concentrations.

Find out more

DIL 502 Expedis®: Setting New Standards in Dilatometry

  • Customizable Setup
    The option to equip the device with single or double furnaces and single or double measuring systems enables temperatures ranging from -180 °C to 2800 °C. This feature offers higher sample throughput and maximum flexibility.
  • High-Precision Measurement
    The NanoEye® opto-electronic displacement system ensures exceptional resolution and linearity.
  • Versatile Sample Holders
    Supports various specimen geometries, including tension measurements.
  • Energy-Efficient Operation
    Electronic thermal stabilization and programmable Eco/Idle Mode reduces energy and gas usage for sustainable performance.

Take your research to the next level with the DIL 502 Expedis® and the TMA 512 Hyperion® Series which deliver exceptional accuracy and control when measuring length change, SinteringSintering is a production process for forming a mechanically strong body out of a ceramic or metallic powder. sintering, softening points, and Phase TransitionsThe term phase transition (or phase change) is most commonly used to describe transitions between the solid, liquid and gaseous states.phase transitions.

Find out more

  • DIL 502 Expedis® Classic

    Designed for industrial applications

    • 3 Furnaces for temperatures from RT to 1600°C
    • Resolution: 2 nm
    • Measurement range: ± 5mm
    • Gas-tight
  • DIL 502 Expedis® Select

    Designed for sophisticated industrial research and contract laboratories

    • 7 Furnaces for temperatures from -180°C to 2000°C
    • Resolution: 1 nm
    • Measurement range: ± 10 mm
    • Vacuum-tight
  • DIL 502 Expedis® Supreme

    Designed for high-end research & development

    • 9 Furnaces for temperatures from -180°C to 2800°C
    • Resolution: 0.1 nm
    • Measurement range: ± 25mm
    • Vacuum-tight
  • TMA 512 Hyperion® Select

    Detect dimensional changes under definded mechanical force

    • 2 Furnaces for temperatures from -70°C to 1600°C
    • Atmospheres: Inert, oxidizing, static, dynamic, vacuum, reducing, hydrogen
    • Force Range: 0.001 N to 3 N
    • Vacuum tight
  • TMA 512 Hyperion® Supreme

    Dimensional changes under defined mechanical force in real-life conditions.

    • 5 Furnaces for temperatures from -150°C to 1600°C
    • Sub-zero temperatures withoutLN2
    • Atmospheres: Inert, oxidizing, static, dynamic, vacuum, reducing, hydrogen, humidity, water vapor
    • Force Range: 0.001 N to 4 N
    • Vacuum tight

Our Quality Promise:

NETZSCH's Unlimited Warranty

At NETZSCH, our commitment to quality goes beyond the instruments themselves. We understand that your investment in advanced technology is a long-term one, and that's why we offer something truly unique – our Unlimited Warranty.

Three advanced thermal analysis instruments, including the TMA 512 *Hyperion®* and DIL 502 *Expedis®*, designed for precision measurement and versatility. Ideal for optimizing material properties at varying temperatures.

The Newly Released HFM 706 Lambda Series

Precision Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.Thermal Conductivity Measurements Tailored to Your Sample Size

Experience future of Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity analysis with the new HFM 706 Lambda Series. Designed for maximum precision and ease of use, this instrument provides fast and reliable Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity measurements for low to medium insulating materials .

and many more fantastic features.

Find out more

Two professionals collaborate at a table, discussing data on a tablet amidst charts and documents, emphasizing teamwork in analysis.

Do you have any questions?

Our experts will be happy to help you.

Contact us

Special Offers

Unbeatable Deals on Premium Thermal Analysis Devices.

These special offers are available for a limited time and only while supplies last. Don't miss out on the chance to equip your laboratory with the finest thermal analysis instruments at a fraction of the cost. Browse our deals today and step into a world of precision, efficiency, and affordability.

NETZSCH Energy Solutions

Batteries - Characterization & Process Technologies

The NETZSCH Group provides total solutions for battery applications, from grinding and dispersing of battery materials to stability, charging and discharging efficiency and even recycling.

Digital illustration of a battery composed of interconnected geometric shapes and glowing lines, symbolizing energy and innovation.
A confident woman engages in an arm wrestling match, displaying determination while smiling, against a male opponent.

Proven Excellence

We promise you Proven Excellence - outstanding performance in all areas.

Learn more