Seminar

27.03.2025

Melbourne

Workshop Melbourne: Mastering Polymer Performance with Thermal Analysis and Rheology

Polymers can generally be divided into three main groups: thermoplastics, elastomers and thermosets. Their thermal properties are analyzed using thermoanalytical systems for product development, quality assurance, failure analysis, and process optimization. During processing, polymers are often heated to shape and then cooled to solidify, requiring an understanding of their temperature-dependent behaviour and flow properties. Functional additives and fillers are compounded into base polymers to achieve desired properties, and their effectiveness needs to be studied. Additionally, polymer products experience various temperature changes during their service life, necessitating knowledge of their thermal behaviour during the design phase. This workshop will explore how advanced thermal analysis and rheology instruments provide comprehensive insights into behaviour of your polymer materials. By combining techniques like Thermogravimetry (TGA), Differential Scanning Calorimetry (DSC), and rotational and capillary rheometry, you can gain valuable information on Thermal StabilityA material is thermally stable if it does not decompose under the influence of temperature. One way to determine the thermal stability of a substance is to use a TGA (thermogravimetric analyzer). thermal stability, Phase TransitionsThe term phase transition (or phase change) is most commonly used to describe transitions between the solid, liquid and gaseous states.phase transitions, mechanical properties, and flow behaviour. These insights are crucial for optimizing polymer performance and ensuring product reliability.

All attendees will receive an individual copy of the NETZSCH DSC handbook.

Refreshments will be provided throughout the day.

Program

8:30Doors Open
9:00Welcome & Introduction to NETZSCH
9:15Unlocking Thermal Secrets: DSC Applications in Thermoplastics, Thermosets, and Rubbers
10:20Decomposing the Details: TGA and Evolved Gas Analysis Uncovered
11:00Morning Tea
11:15Flowing Insights: The Art and Science of Rheology in Polymers
12:15Dynamic Behavior Unveiled: A Journey Through DMA
13:00Lunch and Networking
14:00Workshop 1 – DSC 300 Caliris®: Live Demonstration
14:45Workshop 2 – Software Innovations for the Polymer Sector
15:30Break
15:35

Electives (choose one):

  • Precision in Expansion: Mastering Thermomechanical Analysis
  • Understanding Polymer Flammability: A Dive into Fire Testing Methods
  • Q&A session with a Rheology Specialist
16:00Invited Guest Talk
16:15Q&A
16:30Farewell

LOCATION DETAILS

The University of Melbourne
Parkville Campus
School of Chemistry
Bld 153, Room 371

COURSE CONVENORS

Dr. Markus Meyer, Chemist
NETZSCH-Gerätebau GmbH, Germany

Andrew Gillen, Materials Engineer
NETZSCH Australia Pty Ltd