自動サンプルチェンジャーDSC 204 F1 Phoenix®-ASCは、ルーチン測定用にデザインされています。昼夜を問わず測定し、ユーザーに時間的余裕をもたらし、最高の効率でDSC 204 F1 Phoenix®を活用することが可能になります。(例えば、週末のキャリブレーション測定等)。
The DSC system with an automatic sample changer can handle up to 192 crucibles/pans evenly distributed on two removable trays. Different types of crucibles/pans are allowed up to 8 mm Ø in and 8 mm in height. A four-needle gripper handles different crucibles by using the appropriate gripping pressure for the chosen pan. For calibration and correction purposes, a fixed strip with additional 12 crucible/pan positions is available. Crucible/pan recognition in flight is available. A crucible/pan and lid data base is linked to the ASC. The sample trays are covered by an automatically controlled cover. After closing the cover, the space above the sample pans is purged by branching gas channels integrated in the cover. The purge gas rate is adapted to opening and closing the cover. For this purpose, a further purge gas inlet is available only for the use with the ASC. A “remove lid” function is integrated to cover the sample while waiting its turn to be inserted into the DSC cell. Alternatively, a piercing device is optionally available for piercing the lid prior to measurement. The DSC system has a refuse bin for disposing lids and non-reusable pans. It is possible to archive the micro-plate trays (storage sample). For better identification, the plates have a serial number and 2D code. The tray identification feature is linked to a crucible/lid data base.The same ASC can also be used with our new TG 209 F1 Libra®.
For adhesives, we recommend the DELOLUX04 high-pressure mercury lamp (315-500 nm), which can easily be triggered using Proteus® software. For paints and inks, we recommend the DSC be equipped with an OmniCure® S2000 lamp. The measurement parameters (e.g. exposure time and intensity) can be programmed and monitored by segment via the Proteus® software. The luminous intensity of the high-pressure mercury lamp can be calibrated with the Radiometer R2000.
UV-硬化用フォト-DSC 204 F1 Phoenix®
Standard Crucibles (Pans) Made of Aluminum for the DSC 204 F1 Phoenix®
Material (Purity)
Temperature Range
Consisting of
Dimension/ Volume
Remarks
Order Number
Al (99.5)
Max. 600°C
Crucible + lid
ø 6 mm; 25/40 μl*
Set of 100, cold weldable**
6.239.2-64.5.00
Al (99.5)
Max. 600°C
Crucible + lid
ø 6 mm; 25/40 μl*
Set of 500, cold weldable**
6.239.2-64.51.00
Al (99.5)
Max. 600°C
Crucible + lid with laser-cut hole (50 μm)
ø 6 mm; 40 μl
Set of 100, cold weldable**
6.239.2-64.8.00
Al (99.5)
Max. 600°C
Crucible + lid with laser-cut hole (50 μm)
ø 6 mm; 40 μl
Set of 500, cold weldable**
6.239.2-64.81.00
Al (99.5)
Max. 600°C
Crucible
ø 6.7mm; 85 μl
Set of 100 pieces
NGB810405
Al (99.5)
Max. 600°C
Lid
100 pieces, for NGB810405
NGB810406
* Crucible (pan) volumes of either 25 μl or 40 μl can be achieved by simply reversing the lid. ** One and the same sealing press is capable of sealing all standard Al crucibles (pans); order no. 6.240.10-80.0.00A.
Crucibles (Pans) for General Applications – DSC 204 F1 Phoenix®
Material (Purity)
Temperature Range
Consisting of
Dimension/ Volume
Remarks
Order Number
Al2O3 (99.7)
Max. 1700°C
Crucible
ø 6.8 mm/85 μl
GB399972
Al2O3 (99.7)
Max. 1700°C
Lid
For GB399972
GB399973
Fused silica
Max. 1000°C
Crucible
ø 6.7 mm/85 μl
GB399974
Fused silica
Max. 1000°C
Lid
For GB399974
GB399975
Pt/Rh (80/20)
Max. 1700°C
Crucible
ø 6.8 mm/85 μl
GB399205
Pt/Rh (80/20)
Max. 1700°C
Crucible
ø 6.8 mm/190 μl
NGB801556
Pt/Rh (80/20)
Max. 1700°C
Lid
For GB399205 and NGB801556
GB399860
Gold (99.9)
Max. 900°C
Crucible + Lid
ø 6.7 mm/85 μl
6.225.6-93.3.00
Silver
Max. 750°C
Crucible + Lid
ø 6.7 mm/85 μl
6.225.6-93.4.00
This instrument is LabV®®️-primed
LabV®®️ takes the data from your analytical instrument: It automatically imports all measurement data into a central and secure database solution, the LabV®®️ software. This allows you to visualize the data in LabV®®️ and to make them searchable. Your data will now be accessible from anywhere. Moreover you have the possibility to generate reports.