PF: Phenol-Formaldehyde Resin

General Properties

Short Name:

Name: 

PF

Phenol-Formaldehyde Resin


Phenol-formaldehyde resins (PF) are thermosetting materials, produced by polycondensation of phenol and formaldehyde. The phenol-formaldehyde resin, Bakelite, was the first fully synthetic, industrially produced polymer. Since the Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing of PF resins is a polycondensation reaction, high-pressure crucibles are recommended.

Structural Formula


Properties

Glass Transition TemperatureThe glass transition is one of the most important properties of amorphous and semi-crystalline materials, e.g., inorganic glasses, amorphous metals, polymers, pharmaceuticals and food ingredients, etc., and describes the temperature region where the mechanical properties of the materials change from hard and brittle to more soft, deformable or rubbery.Glass Transition Temperature70 to 120°C
Melting Temperatures and EnthalpiesThe enthalpy of fusion of a substance, also known as latent heat, is a measure of the energy input, typically heat, which is necessary to convert a substance from solid to liquid state. The melting point of a substance is the temperature at which it changes state from solid (crystalline) to liquid (isotropic melt).Melting Temperature-
Melting Temperatures and EnthalpiesThe enthalpy of fusion of a substance, also known as latent heat, is a measure of the energy input, typically heat, which is necessary to convert a substance from solid to liquid state. The melting point of a substance is the temperature at which it changes state from solid (crystalline) to liquid (isotropic melt).Melting Enthalpy-
Decomposition reactionA decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. Decomposition Temperature450 to 555°C
Young's Modulus5600 to 12000 MPa
Coefficient of Linear Thermal Expansion (CLTE/CTE)The coefficient of linear thermal expansion (CLTE) describes the length change of a material as a function of the temperature.Coefficient of Linear Thermal Expansion15 to 50 *10-6/K
Specific Heat Capacity 1.0 to 1.3 J/(g*K)
Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.Thermal Conductivity0.35 to 0.70 W/(m*K)
DensityThe mass density is defined as the ratio between mass and volume. Density1.40 to 1.80 g/cm³
MorphologyThermoset
General propertiesVery hard and stiff. Good chemical resistance. Low inflammability
ProcessingCompression, injection molding, extrusion molding, transfer molding, foaming
ApplicationsElectrical industry (e.g., for circuit boards, plugs). Building industry (weather-resistant glue, for production of insulating materials). Vehicle construction. Matrix for fiber-reinforced composites

NETZSCH Measurement

InstrumentDSC 204 F1 Phoenix®
Sample Mass26.26 mg
IsothermalTests at controlled and constant temperature are called isothermal.Isothermal Phase10 min
Heating/Colling Rates

5 K/min 1st heat.

10 K/min cooling

20 K/min 2nd heat.

Crucible

High-pressure steel

crucibles, closed

AtmosphereN2 (40 ml/min)

Evaluation

The 1st heating (blue) shows a Glass Transition TemperatureThe glass transition is one of the most important properties of amorphous and semi-crystalline materials, e.g., inorganic glasses, amorphous metals, polymers, pharmaceuticals and food ingredients, etc., and describes the temperature region where the mechanical properties of the materials change from hard and brittle to more soft, deformable or rubbery.glass transition at approx. 48°C (midpoint) with an overlapping enthalpy RelaxationRelaxation은 고무에 일정한 변형률이 가해지면, 변형률을 유지하기 위해 필요한 힘은 일정하지는 않지만 시간에 따라 감소합니다. 이러한 특성을 ‘응력 완화’라고 부릅니다. 응력완화의 원인이 되는 과정은 물리적 또는 화학적 그리고 정상적인 조건 하에, 둘 다 동시에 일어날 수 있습니다. relaxation, followed by a multi-step ExothermicA sample transition or a reaction is exothermic if heat is generated.exothermalCuring (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing effect with peak temperatures of 141°C and 206°C and a total enthalpy of 191 J/g. In the following 2nd heating (red), the Glass Transition TemperatureThe glass transition is one of the most important properties of amorphous and semi-crystalline materials, e.g., inorganic glasses, amorphous metals, polymers, pharmaceuticals and food ingredients, etc., and describes the temperature region where the mechanical properties of the materials change from hard and brittle to more soft, deformable or rubbery.glass transition shifted to approx. 72°C (midpoint) as a result of the extensive Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing in the previous heating step.