Highest specification rheometer bearing system
The Kinexus ultra+ rheometer has the highest sensitivity air bearing and widest torque range, coupled with the unprecedented vertical (axial) control capabilities of the Kinexus platform, for advanced rheological testing. Unique sequence-driven rSpace software enables fully customizable test design to allow researchers to set-up and investigate tailored rheological test protocols.
The Kinexus ultra+ rheometer
It incorporates technological innovations that enable optimal flexibility in rheological test capabilities and protocols - for advanced research.
- All modes of rheological operation – StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress control, shear rate control and direct StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain controlled oscillation at demand StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain amplitude for accurate control of sample strain history.
- Unprecedented dual-action capabilities for both shear and vertical testing.
- Highest specification air bearing with ultra-low torque offset to minimise data corrections.
- Exceptional vertical travel and gapping capabilities with ultra-responsive and highly sensitive normal force system for class-leading performance.
- Unique rSpace software interface that offers total flexibility of test set-up - from fully customizable test design for new and advanced research capabilities to sequence-driven Standard Operating Procedure (SOP)-type functionality.
- Wide variety of measurement geometries optimized for rheological characterization of complex fluids and soft solids, including dispersions, emulsions, polymer and surfactant solutions, pastes and gels.
- Intelligent geometry recognition with full auto-configuration and user feedback on system status to guarantee robust data for all measurements.
- Complete sample history from the point of loading onto the rheometer available in data file as standard – because ensuring reliable rheology data for complex Non-NewtonianA non-Newtonian fluid is one that exhibits a viscosity that varies as a function of the applied shear rate or shear stress.non-Newtonian materials actually starts before a measurement takes place.
- Unique ‘plug and play’ cartridge system for all temperature and environmental controllers – all mechanical, power, communication and fluid connections made in one simple action.
- Multifunctional accessory design – plate cartridges with interchangeable lower plates for a cost-effective solution addressing the widest application coverage.

Request a Quote
Technical Data
Temperature range (max.)
-40°C to 350°C
Technology
Rheometry - rotational

Torque range:
1.0nNm to 225mNm
Literatura przedmiotu
- NETZSCH-Webinar Analiza termomechaniczna (TMA) - wprowadzenie do metody
- NETZSCH-Webinar_Metody sprzężone stosowane w analizie termicznej (EGA)
- NETZSCH-Webinar Badanie i identyfikacja tworzyw sztucznych po procesie recyklingu metodami analizy termicznej (DSC i TG)
- Badanie właściwości mechanicznych materiałów metodą High-Force DMA
- Wpływ różnych czynników na wyniki pomiarów TG-DSC-DTAJednoczesna analiza termiczna (STA) jest metodą stanowiącą połączenie dwóch technik termoanalitycznych: termograwimetrii (TG) i skaningowej kalorymetrii różnicowej (DSC) w odniesieniu do jednej próbki. Metoda ta pozwala kompleksową charakterystykę szerokiej grupy materiałów pod względem ich właściwości termicznych, między innymi takich jak: temperatury topnienia, krystalizacji, zeszklenia, przemiany fazowe, stabilność termiczna, zawartość wilgoci, popiołów, organiki, wpływ reaktywnych atmosfer ma materiał. Ze względu na złożoność metody STA dobór optymalnych parametrów pomiaru jest kluczowym czynnikiem do otrzymania poprawnych wyników. W niniejszym webinarium zostaną omówione kluczowe parametry i czynniki, które mają wpływ na wyniki pomiarowe z których najważniejsze to: - odpowiednie przygotowanie próbek - odpowiedni dobór tygli i holderów pomiarowych - dobór optymalnego programu temperaturowego - wpływ szybkości grzania, masy próbki oraz atmosfery pomiarowej Serdecznie zapraszamy Państwa do udziału !

Product Information
Wideo
Rheology Part 1 - The Basics of Viscosity
Rheology Part 2 - Basics of Viscoelasticity