Многорежимный калориметр (MMC)
Многорежимный калориметр (Multiple Module Calorimeter (MMC)A multiple mode calorimeter device consisting of a base unit and exchangeable modules. One module is prepared for accelerating rate calorimetry (ARC), the ARC-Module. A second one is used for scanning tests (Scanning Module) and a third one is related to battery testing for coin cells (Coin Cell Module).MMC) предназначен для исследований химических реакций, фазовых переходов, теплоемкости, при этом масса образца может составлять граммы.
Это позволяет тестировать как органические, так и неорганические материалы, многокомпонентные смеси или растворы.
Как и адиабатические калориметры серии Адиабатическая реакционная калориметрия (ARC)The method describing isothermal and adiabatic test procedures used to detect thermally exothermic decomposition reactions.ARC®, многорежимный калориметр (Multiple Module Calorimeter (MMC)A multiple mode calorimeter device consisting of a base unit and exchangeable modules. One module is prepared for accelerating rate calorimetry (ARC), the ARC-Module. A second one is used for scanning tests (Scanning Module) and a third one is related to battery testing for coin cells (Coin Cell Module).MMC) может использоваться для адиабатических измерений, которые необходимы для безопасного производства или исследований энергоемких материалов. Многорежимный калориметр (Multiple Module Calorimeter (MMC)A multiple mode calorimeter device consisting of a base unit and exchangeable modules. One module is prepared for accelerating rate calorimetry (ARC), the ARC-Module. A second one is used for scanning tests (Scanning Module) and a third one is related to battery testing for coin cells (Coin Cell Module).MMC) успешно сочетает достоинства обоих методов DSC и ARC®.
Multiple Module Calorimeter MMC 274 Nexus®
Various Modules in One Calorimeter
Exchangeable calorimeter modules are available for different applications. The Accelerating Rate Calorimeter (Модуль ARCA calorimeter module being part of the Multiple Module Calorimeter (MMC) allowing for HWS tests according to accelerated rate calorimetry (ARC).ARC®) module can be used for standard process safety work. The External heater module can be employed for more sophisticated measurements.
Application Literature
MEASUREMENT WANTED?
Our NETZSCH applications laboratory is providing contract testing services for a wide range of industries and research centers. It is equipped with state-of-the-art testing instruments allowing for a variety of thermal analysis measurements to be carried out.
Consult with the experts in our applications labs to choose the best-suited measuring method for your specific needs.