The dilatometer DIL 402 ExpedisClassic offers state-of-the-art dilatometer technology and is designed for sophisticated applications.
Like all instruments of the DIL Expedis series, the Classic version features the revolutionary NanoEye measuring cell; a new dimension in measuring range and accuracy.
NanoEye– Every Nanometer Counts.
A New Dimension in Measuring Range and Accuracy
In classical dilatometry, the two parameters measurement range and resolutionmostly seem diametrically opposed. If the resolution goes up, the measuring range usually goes down and vice versa. NanoEye, the novel opto-electrical displacement system, features perfect linearity and maximum resolution over a measuring range which was impossible to realize until now.
Functional Principle
During a test run, if the sample expands, all green components in the graphics move backwards with the help of a linear guide (marked in blue). The optical encoder determines the corresponding length change directly on the appropriate scale.
Key Feature
All-In-One Design & Long Life Cycle
The DIL ExpedisClassic is available as a single or dual/differential system. In both versions, the all-in-one design incorporates all hardware components which are usually necessary for precise dilatometer measurements. There is no inconvenient cable tangle nor is an external chiller required.
ExpedisClassic supports your smooth production flow by maintenance-free operation, low work load, long life cycle, simplified and safe operation. The system’s sophisticated design also includes effortless exchanging of the sample holder system with no risk of distortion.
Key Feature
Ease of Use
Major simplification begins with preparation of the measurement by using method-based test routines predefined by the operator.
The MultiTouch feature places the sample into the optimum position using a unique, tail-like motion. The initial sample length is then automatically determined at a predefined contact force. The furnace closing is made smooth by cushioning which guarantees stable sample positioning.
Exchanging the furnace is simple and requires no detailed experience. Only a few clicks are needed to start the measurement
Key Feature
Controlled Contact Force
The controlled contact force allows the operator to measure small, delicate, fragile or foamed samples without risk of breakage and any non-reproducible deformation and to keep the contact pressure over the entire measurement time constant.
Also, this feature allows a highly reproducible sample length measurement independent of the respective operator. Sliding and rolling friction, stick-slip effects, etc. in the measurement system will now also be avoided.
The future is now!
Bring our devices into your laboratory with the click of a button.
Simply scan the QR code and get a 3D model of the instrument directly on your mobile phone or tablet. With the help of the latest AR Technology (Artificial Reality), the 3D model can easily be placed in your laboratory in its original life size. This function is browser-based and requires no app.
Find out and be amazed!
Request a Quote
Technical Data
Heating Rates
Sample Holder System
Displacement system
Temperature accuracy
1 K
Temperature precision
0.1 K
Repeatability of m. Coefficient of Linear Thermal Expansion (CLTE/CTE)The coefficient of linear thermal expansion (CLTE) describes the length change of a material as a function of the temperature.CTE
10-8 1/K
Measuring range
± 5000 μm
Resolution
2 nm (over the entire measuring range)
Gas control
1-way, optional 3-way switch