19.09.2023 by Aileen Sammler
Thermomechanical Analysis of Thin Metal Layers
Thin metal foils are used in a variety of industries. The thermal analysis of thin metal films provides important information about the behavior of metals under different conditions. Specifically, knowledge of a metal's RelaxationRelaxation은 고무에 일정한 변형률이 가해지면, 변형률을 유지하기 위해 필요한 힘은 일정하지는 않지만 시간에 따라 감소합니다. 이러한 특성을 ‘응력 완화’라고 부릅니다. 응력완화의 원인이 되는 과정은 물리적 또는 화학적 그리고 정상적인 조건 하에, 둘 다 동시에 일어날 수 있습니다. relaxation properties can be helpful in selecting or optimizing materials/material compositions for specific applications, such as in electronics, aerospace or automotive engineering.
Thin metal foils are used in a variety of industries, for example:
- Electronics: Thin metal layers are used as conductive tracks in flexible circuits, as shields and in various other electronic components.
- Packaging: In the food industry, metal foils, especially aluminum foils, are often employed for packaging as they provide a barrier against light, oxygen, and moisture.
- Energy: Thin metal foils are applied as electrodes or current collectors in batteries and fuel cells.
- Aerospace: Thin metal foils can be found in various components of aircraft and spacecraft, especially when weight and space are taken into consideration.
- Medicine: Thin gold foils are used as radiation enhancers in radiation therapy.
In all these applications, materials with high RelaxationRelaxation은 고무에 일정한 변형률이 가해지면, 변형률을 유지하기 위해 필요한 힘은 일정하지는 않지만 시간에 따라 감소합니다. 이러한 특성을 ‘응력 완화’라고 부릅니다. 응력완화의 원인이 되는 과정은 물리적 또는 화학적 그리고 정상적인 조건 하에, 둘 다 동시에 일어날 수 있습니다. relaxation strength are important to maintain contact over an extended period – even at higher temperatures. This is because, over time, the mechanical properties of metal foils can change due to various factors such as temperature, moisture or mechanical StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress.
The investigation of thin metal films by means of TMA provides important information about the behavior of metals under different conditions. In addition to thermal expansion, knowledge of a metal's RelaxationRelaxation은 고무에 일정한 변형률이 가해지면, 변형률을 유지하기 위해 필요한 힘은 일정하지는 않지만 시간에 따라 감소합니다. 이러한 특성을 ‘응력 완화’라고 부릅니다. 응력완화의 원인이 되는 과정은 물리적 또는 화학적 그리고 정상적인 조건 하에, 둘 다 동시에 일어날 수 있습니다. relaxation properties specifically can be helpful in selecting or optimizing materials/material compositions for specific applications, such as in electronics, aerospace or automotive engineering.
In our current application note, we examined the RelaxationRelaxation은 고무에 일정한 변형률이 가해지면, 변형률을 유지하기 위해 필요한 힘은 일정하지는 않지만 시간에 따라 감소합니다. 이러한 특성을 ‘응력 완화’라고 부릅니다. 응력완화의 원인이 되는 과정은 물리적 또는 화학적 그리고 정상적인 조건 하에, 둘 다 동시에 일어날 수 있습니다. relaxation behavior of different metal foils using thermomechanical analysis (TMA). Here, our NETZSCH TMA 402 Hyperion® with the „displacement control” software option was used.
Read more and learn about:
- the changing properties of metal foils at consistently elevated temperatures
- the influence of composition on the RelaxationRelaxation은 고무에 일정한 변형률이 가해지면, 변형률을 유지하기 위해 필요한 힘은 일정하지는 않지만 시간에 따라 감소합니다. 이러한 특성을 ‘응력 완화’라고 부릅니다. 응력완화의 원인이 되는 과정은 물리적 또는 화학적 그리고 정상적인 조건 하에, 둘 다 동시에 일어날 수 있습니다. relaxation behavior of metal films
- the measurement of metal layers made of CuAg (copper-silver alloy), CuBe (copper-beryllium alloy), and a Pd alloy (palladium) using 3-point bending