The compact test chamber TDW 4240 is designed for testing elements and components used in construction, such as windows, profiles, doors and domes and brick walls).
They basically simulate the temperature and the natural convection inside and outside a building. Optionally, the humidity level in the two sections of the chamber can be set as needed. The HotBox software at the measurement and control unit is used to set all parameters as well as for complete data logging, detailed analysis and printing of test reports. There are also other devices, accessories and materials available that allow for sample preparation and conditioning to optimize the testing procedure.
![](https://analyzing-testing.netzsch.com/_Resources/Persistent/6/8/a/3/68a3c72c070498a79fafa9717586ca41ddb9bcaa/csm_NTA_Determination_of_thermal_transmittance_U_according_to_ISO_8990_c2dedc7e98-892x595-600x400.webp)
Features at a Glance
- Insulated warm and cold sections with heat exchangers and air deflectors, radial fans, roll chassis on guiding rails and 12-point locking system
- Hotbox with axial fan, air deflectors, roll chassis and hydraulic cylinders
- Insulated test frame with roll chassis and openings for sample insertion via forklift
- Recirculation cooler with water cooling for temperature control of warm and cold sections
- Control rack unit with measuring and control modules, PC, printer and 23" monitor
- Interfaces: 1 x RS232, 2 x USB, 1x Gigabit Ethernet
- 2 IsothermalTests at controlled and constant temperature are called isothermal.isothermal blocks with 60 measuring points each, 1 set of thermocouples, flow sensors, TDW 4240: 2 heat flow meters with guard plates
- Single license for HotBox software
- TDW 4240: 6 calibration panels with factory calibration certificate
- 1 set stainless steel guide rails for warm and cold sections
![](https://analyzing-testing.netzsch.com/_Resources/Persistent/8/1/0/7/81071b5f6fe86b53f85b55b97a2222d6d296e75f/web_AdobeStock_296563182-1277x719-1277x719.webp)
Request a Quote
Technical Data
Measuring Range
U: 0.12 to 3.70 W/(m²·K)
Sample Dimensions
Variant A: 1480 mm x 1230 mm
Variant B: 2180 mm x 1480 mm
Door:
Variant A: 2180 mm x 1230 mm
Variant B: 2180 mm x 2000 mm
Specimen thickness (H)
![](https://analyzing-testing.netzsch.com/_Resources/Persistent/4/5/f/a/45fabf04ecc245adb813b1b85e5e21a6071b2113/NTA_Hotbox_Test_Chambers_TDW_4240_test_frame-600x600.webp)
Temperature Range:
Cold Section:
TDW 4240: -15°C to 40°C
Warm Section:
TDW 4240: +10°C to 60°C
Dimensions:
Closed: 400 cm x 400 cm x 405 cm
Open: 400 cm x 610 cm x 405 cm
Power Supply:
230 V/400 V/50 Hz
![](https://analyzing-testing.netzsch.com/_Resources/Persistent/3/1/8/b/318b5cc61f48104c5bb795c97577ea89d4a71a92/Footage_NETZSCH_67-1920x1079-1650x927.webp)