NETZSCH LFA 717 HyperFlash HT instrument for thermal conductivity analysis, featuring a user-friendly control panel and logo for basic course.
Learn, Apply, Achieve.

Basic Course
LFA 717 Hyperflash HT

Language: English - Duration: 86 Min.

This Online course explains the

  • theory of thermal conductivity,
  • your LFA 717 HyperFlash® HT instrument itself,
  • the theory of LFA,
  • which factors have an influence on your LFA Measurement,
  • how to prepare your samples and sample holders
  • how to start a measurement and
  • how to evaluate thermal conductivity and diffusivity,
  • how to do a standard calibration run
  • and finally how to export the date

Course Information

  • Language: English
  • Total Course Duration: 86 Min.
  • Duration of use: unlimited
  • Price: free of charge

Syllabus

  • Introduction of the speaker and the agenda
  • Introduction
  • What is Thermal Conductivity?
  • Methods for Determination the Thermal Conductivity
  • Application Examples
  • Summary
  • Introduction on the Product Guide of the NETZSCH LFA 717 HyperFlash® HT
  • Instrument Overview and Connections
  • Detector and Zoom Optics
  • Front Panel
  • Opening and Closing the Furnace
  • Opening the Device: Internal Elements
  • Standard Sample Holders
  • Additional Tools
  • Summary
  • Introduction
  • Introduction to the Flash Method
  • Pulse Execution and Signal Determination
  • Results Obtained from Signal Analysis
  • Parker Model: Adiabatic Conditions
  • Standard Model (Improved Cape-Lehman Model)
  • Additional Models
  • Pulse Correction
  • Baseline Types
  • Summary
  • Introduction on influential factors
  • Influence of the Graphite Spray
  • Influence of the Sample Geometry
  • Influence of the Atmosphere
  • Influence of the Specific Heat Capacity Determination
  • Summary
  • Introduction on Sample Preparation
  • Sample Geometry
  • How to Determine the Sample Thickness
  • How to Determine the Sample Density
  • Optimizing the Radiative Properties of the Surface
  • Summary
  • Introduction
  • How to Fill the Detector
  • Checking and Cleaning the Furnace Windows
  • Placing the Sample and the Sample Holder into the Furnace
  • Proteus® LFA Measurement Software: Before Measurement
  • Proteus® LFA Measurement Software: Starting a Measurement
  • Summary
  • Introduction on evaluating a measurement
  • Open the Database and the Measurement in the NETZSCH Proteus® LFA Analysis
  • Thermal Diffusivity Analysis
  • Specific Heat Capacity Determination
  • Thermal Conductivity Determination
  • Export of the Analysis Results
  • Summary
  • Course Summary
رجل في منتصف العمر وامرأة شابة يتعاونان على طاولة لتحليل البيانات على جهاز لوحي في مكتب حديث.

الاستشارات والمبيعات

هل لديك أسئلة أخرى حول الأداة أو الطريقة؟ هل ترغب في التحدث إلى مندوب مبيعات؟

الخدمة والدعم

هل لديك بالفعل جهاز NETZSCH وتحتاج إلى دعم فني أو قطع غيار؟

ممثل دعم العملاء المبتسم في مكتب حديث، يشارك في محادثة أثناء العمل على الكمبيوتر.
يقوم اثنان من فنيي المختبر بتحليل بيانات التحليل الحراري على شاشة الكمبيوتر، وعرض برنامج NETZSCH في بيئة معملية.

الأكاديمية والتدريب

هل تريد منا تقديم تدريب مباشر عبر الإنترنت أو تدريب في الموقع في المختبر لتلبية متطلباتك الخاصة؟

AI Overview
An error occurred. Please try again.