Highlights
Analyze the unique thermal behavior of materials and their components
TG 309 Libra® Classic
The TG 309 Libra® Classic is the device with the best price-performance ratio in the Libra® series. It is the ideal instrument for Quality Control. The Classic offers a temperature range from 10 °C up to 1025 °C. In addition, it can be equipped with a 20-position ASC (Automatic Sample Changer).
Get Results Faster Without a Baseline Run
To ensure accurate mass change values, a baseline run is typically conducted under test conditions that are identical in terms of heating rate, gas type, and gas flow.
The baseline takes factors such as heating rate, crucible type and geometry into account while also accounting for instrument and buoyancy effects, thus allowing these to be subtracted from the sample measurement.
The TG 309 Libra® typically eliminates the need for a separate baseline run when using the integrated BeFlat® baseline run for typical temperature measurements. This significantly speeds up tests.
20 Times Faster Thanks to High Heating Rates
The TG 309 Libra® has a low-volume furnace. It supports rapid heating rates of up to 200K/min over the entire temperature range and fast ballistic cooling from 1025°C down to room temperature. This allows for faster analysis results, even at high temperatures, with a turnaround time of just a few minutes.
More Comprehensive and Faster Characterization by Patented c-DTA®
In direct contact with the sample crucible, the sample thermocouple measures temperature variations in the material. This enables more thorough characterization of sample properties and determination of endothermic (e.g., melting) and exothermic (e.g., oxidation) effects during thermogravimetric investigations. In addition, c-DTA allows for temperature calibration using DSC reference materials.
تحليل السلوك الحراري الفريد للمواد ومكوناتها
برج الميزان TG 309 TG 309 الكلاسيكية هو الجهاز الذي يتمتع بأفضل نسبة سعر إلى أداء في سلسلة Libra®. إنه الجهاز المثالي لمراقبة الجودة. يوفر الجهاز الكلاسيكي نطاق درجة حرارة من 10 درجات مئوية حتى 1025 درجة مئوية. وبالإضافة إلى ذلك، يمكن تجهيزه بـ 20 موضع ASC (مبادل العينات الأوتوماتيكي).
الحصول على نتائج أسرع بدون تشغيل خط الأساس
لضمان دقة قيم تغير الكتلة، عادةً ما يتم إجراء تشغيل خط الأساس في ظل ظروف اختبار متطابقة من حيث معدل التسخين ونوع الغاز وتدفق الغاز.
ويأخذ خط الأساس عوامل مثل معدل التسخين ونوع البوتقة والهندسة في الاعتبار مع مراعاة تأثيرات الجهاز والطفو، مما يسمح بطرحها من قياس العينة.
يلغي TG 309 Libra® عادةً الحاجة إلى تشغيل خط أساس منفصل عند استخدام خط الأساس المدمج BeFlat® لقياسات درجة الحرارة النموذجية. وهذا يسرّع الاختبارات بشكل كبير.
أسرع 20 مرة بفضل معدلات التسخين العالية
يحتوي TG 309 Libra® على فرن منخفض الحجم. وهو يدعم معدلات تسخين سريعة تصل إلى 200 كلفن/الدقيقة على نطاق درجة الحرارة بالكامل والتبريد الباليستي السريع من 1025 درجة مئوية إلى درجة حرارة الغرفة. يتيح ذلك الحصول على نتائج تحليل أسرع، حتى في درجات الحرارة المرتفعة، مع وقت استجابة لا يتجاوز بضع دقائق فقط.
توصيف أكثر شمولاً وأسرع بواسطة تقنية c-DTA® الحاصلة على براءة اختراع
عند التلامس المباشر مع بوتقة العينة، تقيس المزدوجات الحرارية للعينة تغيرات درجة الحرارة في المادة. ويتيح ذلك توصيفًا أكثر شمولاً لخصائص العينة وتحديد التأثيرات الماصة للحرارة (على سبيل المثال، الذوبان) والتأثيرات الطاردة للحرارة (على سبيل المثال، الأكسدة) أثناء إجراء فحوصات قياس الثقل الحراري. وبالإضافة إلى ذلك، يسمح c-DTA® بمعايرة درجة الحرارة باستخدام المواد المرجعية للتحلل الحراري الحراري الموزون؛ ويتم ذلك عادةً في بيئة مغناطيسية.
Method
Thermogravimetric Analysis / Thermogravimetry
What is Thermogravimetry?
Thermogravimetry has the ability for differentiation between individual components based on their distinct thermal behavior. By analyzing weight-loss profiles, users can deduce the composition of complex samples, enabling deeper understanding of their structure and properties.
Revealing the Mysteries of Complex Mixtures and Material Transformations
Thermogravimetry (TG) is renowned for its precision and sensitivity. By subjecting a sample to controlled temperature increments while continuously measuring its weight change, TGA can detect even the slightest alterations in a material‘s mass. This level of sensitivity allows for pinpointing the exact temperatures at which various transformations occur, such as decomposition, volatilization, or oxidation. As a result, TGA provides valuable insights into a material‘s composition, providing such information as stability and degradation data for polymers along with data for material characterization and formulation.
Ensuring Product Quality and Safety
For industries like pharmaceuticals, chemicals, and food, ensuring product stability is very important. Thermogravimetry plays a vital role in evaluating the thermal stability of materials over time. By subjecting samples to extended thermal cycling, researchers can assess their long-term stability, obtain initial information about shelf-life, and identify potential degradation pathways. This information is critical for quality control and regulatory compliance.
Unlimited Versatility: Tailored for Diverse Applications
One of the remarkable qualities of thermogravimetry is that it can be adapted to a wide range of applications. From the polymer industry to materials engineering, and from pharmaceutical research to environmental science, TGA is a versatile technique that transcends disciplinary boundaries. Its capability of providing fundamental insights into materials makes it indispensable for materials characterization, from quality control to industrial research and academic applications.
Measuring Principle
Thermogravimetric analysis (TGA) is a precise analytical technique used to track changes in the mass of a sample over time and/or temperature under a defined and controlled environment with respect to heating rate, gas atmosphere, flow rate, crucible type, etc. It can accurately detect weight changes down to fractions of a microgram. This high sensitivity allows for the determination of even the smallest changes in the physical and chemical properties of a material.
Specifications
طلب عرض أسعار
البيانات الفنية
نطاق درجة الحرارة
دقة التوازن
معدلات التدفئة والتبريد
دقة درجة الحرارة:
0.15 كلفن
نطاق قياس عريض:
2000 ميليجرام
إحكام التفريغ:
1 ملي بار
حجم بوتقة العينة:
حتى 350 ميكرولتر
الغلاف الجوي:
خامل، مؤكسد، مختزل، ثابت، ديناميكي
مبادل العينات الأوتوماتيكي:
ASC مع 20 وضعًا متاحًا اختياريًا
Compact 20-Sample ASC on a Removable Sample Carousel
The cost-effective TG 309 Libra® Classic can be equipped with an optional automatic sample changer (ASC) for up to 20 samples and references. The gripper safely removes the crucible from the magazine and gently places it in position on the sensor. The samples are placed in a removable ASC insert which allows for preparation away from the instrument.
Software
AutoEvaluation
Objective Results Right After a Measurement
AutoEvaluation is a self-acting evaluation routine for thermogravimetric (TGA) measurements. It autonomously evaluates all significant mass changes, including mass loss and mass gain, instantly; generates the DTG derivative curve; and automatically evaluates the corresponding peak temperatures. When incorporated into a measurement method, evaluated TGA and DTG curves appear immediately after the measurement is completed. Moreover, users can customize the size of mass changes to be detected and the selection of evaluation results to be displayed.
Identify
The Database for Material Identification and Quality Control
Identify is a unique software tool in the field of thermal analysis for the identification and classification of materials. Besides 1:1 comparisons with individual database measurements or literature data, it is also possible to compare a measurement with classes (groups of measurements or literature data). Such classes can consist of data of the same material type, allowing for material identification. A class can also contain reference curves for pass/fail testing in quality control. The included NETZSCH libraries contain more than 1300 entries from the application areas of polymers, organics, pharmaceuticals, food, cosmetics, inorganics, ceramics, metals and alloys. Signal types currently supported include DSC, DSC cp, TGA, STA, DIL/TMA and DMA. Users can expand the database with libraries containing an unlimited amount of their own data. Ultimately, this growing collection of database entries and measurement conditions can also be extremely useful in preparing future experiments.
It is particularly advantageous that Identify can even simultaneously incorporate two types of measurements, such as TGA and DSC or c-DTA®, during identification, this can significantly reduce multiple interpretations, and thus increase the chances of correct material identification. As shown in the example, the evaluated TGA and c-DTA® curves can be used together by Identify: Analysis reveals that the TGA decomposition result is very similar to that of the POM-H polymer found in the database; also, there is a DSC curve for POM-H that agrees well with the melting effect at a peak temperature of 183°C, which is also reflected in the c-DTA® curve of the input measurement. The material is thus identified as POM-H material with high confidence; all other polymer types present in the database can be ruled out.
Eco Mode – Uses Energy Only when Needed
FOCUS ON EFFICENCY AND A MORE SUSTAINABLE LABORATORY
To obtain accurate thermogravimetric results with low drift, a thermostat is used to condition the instrument. A constantly running thermostat not only consumes energy, but also produces waste heat that must be controlled by air conditioning systems.
On a busy day in the laboratory, the TGA instrument will be in use for around 10 to 12 hours. If no measurements are scheduled overnight or over the weekend, the instrument will either have to be shut down, resulting in a stabilization time before it can be used again, or it will remain on, consuming energy that is not technically required. Sustainability in the laboratory environment is becoming increasingly important.
The TG 309 Libra® offers an energy-saving Eco Mode, which allows the chiller to be switched off automatically via software, making it much more economical to run. The software provides a user-defined schedule to activate either Idle or Eco Mode. This eliminates the waiting time that would occur if the instrument was completely shut down, by reactivating the gas flow and thermostat as required, so that the instrument is ready for the first measurement on schedule. Switching the unit to Eco Mode will save 1 kW of electricity, which can sum up to over 6000 kWh per year. This makes the instrument cheaper to run and effortlessly reduces your carbon footprint
This instrument is LabV®️-primed
LabV®️ takes the data from your analytical instrument: It automatically imports all measurement data into a central and secure database solution, the LabV®️ software. This allows you to visualize the data in LabV®️ and to make them searchable. Your data will now be accessible from anywhere. Moreover you have the possibility to generate reports.
المستقبل الآن!
أحضر أجهزتنا إلى مختبرك بنقرة زر واحدة.
ما عليك سوى مسح رمز الاستجابة السريعة ضوئياً والحصول على نموذج ثلاثي الأبعاد للأداة مباشرةً على هاتفك المحمول أو جهازك اللوحي. وبمساعدة أحدث تقنيات الواقع المعزز (الواقع الاصطناعي)، يمكن بسهولة وضع النموذج ثلاثي الأبعاد في مختبرك بالحجم الطبيعي الأصلي. تعتمد هذه الوظيفة على المتصفح ولا تحتاج إلى تطبيق.
اكتشف ذلك واندهش!
هذه الأداة مجهزة بخاصية LabV®-primed
يأخذ LabV®️ LabV® البيانات من جهازك التحليلي: يقوم تلقائيًا باستيراد جميع بيانات القياس إلى حل قاعدة بيانات مركزي وآمن، وهو برنامج LabV®️. يسمح لك هذا بتصور البيانات في LabV®️ وجعلها قابلة للبحث. يمكن الوصول إلى بياناتك الآن من أي مكان. وعلاوة على ذلك لديك إمكانية إنشاء تقارير.
Consultancy & Sales
Do you have further questions about the instrument or the method and would like to speak to a sales representative?
Service & Support
Do you already have an instrument and need technical support or spare parts?