LFA 717 Hyperflash instrument for thermal conductivity analysis, featuring a user-friendly interface and E-Learning course badge.
Learn, Apply, Achieve.

Basic Course
LFA 717 HyperFlash® 

Language: English - Duration: 86 Min.

This Online course explains the

  • theory of thermal conductivity,
  • your LFA 717 HyperFlash® instrument itself,
  • the theory of LFA,
  • which factors have an influence on your LFA Measurement,
  • how to prepare your samples and sample holders
  • how to start a measurement and
  • how to evaluate thermal conductivity and diffusivity,
  • and finally how to export the date

Course Information

  • Language: English
  • Total Course Duration: 86 Min.
  • Duration of use: unlimited
  • Price: free of charge

Syllabus

  • Introduction of the speaker and the agenda
  • Introduction
  • What is Thermal Conductivity?
  • Methods for Determination the Thermal Conductivity
  • Application Examples
  • Summary
  • Introduction on the Product Guide of the NETZSCH LFA 717 HyperFlash®
  • Instrument Overview and Connections
  • Detector and Zoom Optics
  • Front Panel
  • Opening and Closing the Furnace
  • Opening the Device: Internal Elements
  • Standard Sample Holders
  • Additional Tools
  • Summary
  • Introduction
  • Introduction to the Flash Method
  • Pulse Execution and Signal Determination
  • Results Obtained from Signal Analysis
  • Parker Model: Adiabatic Conditions
  • Standard Model (Improved Cape-Lehman Model)
  • Additional Models
  • Pulse Correction
  • Baseline Types
  • Summary
  • Introduction on influential factors
  • Influence of the Graphite Spray
  • Influence of the Sample Geometry
  • Influence of the Atmosphere
  • Influence of the Specific Heat Capacity Determination
  • Summary
  • Introduction on Sample Preparation
  • Sample Geometry
  • How to Determine the Sample Thickness
  • How to Determine the Sample Density
  • Optimizing the Radiative Properties of the Surface
  • Summary
  • Introduction
  • How to Fill the Detector
  • Checking and Cleaning the Furnace Windows
  • Placing the Sample and the Sample Holder into the Furnace
  • Proteus® LFA Measurement Software: Before Measurement
  • Proteus® LFA Measurement Software: Starting a Measurement
  • Summary
  • Introduction on evaluating a measurement
  • Open the Database and the Measurement in the NETZSCH Proteus® LFA Analysis
  • Thermal Diffusivity Analysis
  • Specific Heat Capacity Determination
  • Thermal Conductivity Determination
  • Export of the Analysis Results
  • Summary
  • Course Summary
Un homme d'âge moyen et une jeune femme collaborent à une table, analysant des données sur une tablette dans un bureau moderne.

Conseil et vente

Vous avez des questions sur l'instrument ou la méthode ? Souhaitez-vous parler à un représentant ?

Service et assistance

Vous avez déjà un instrument NETZSCH et vous avez besoin d'une assistance technique ou de pièces de rechange ?

Représentant souriant du service clientèle dans un bureau moderne, engagé dans une conversation tout en travaillant sur un ordinateur.
Deux techniciens de laboratoire analysent les données d'analyse thermique sur un écran d'ordinateur, présentant le logiciel NETZSCH dans un environnement de laboratoire.

Académie et formation

Souhaitez-vous que nous vous proposions une formation en ligne en direct ou une formation sur place au laboratoire pour répondre à vos besoins spécifiques ?

AI Overview
An error occurred. Please try again.