Basic Course
LFA 717 HyperFlash®
Language: English - Duration: 86 Min.
This Online course explains the
- theory of Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity,
- your LFA 717 HyperFlash® instrument itself,
- the theory of LFA,
- which factors have an influence on your LFA Measurement,
- how to prepare your samples and sample holders
- how to start a measurement and
- how to evaluate Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity and diffusivity,
- and finally how to export the date
Syllabus
- Introduction of the speaker and the agenda
- Introduction
- What is Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.Thermal Conductivity?
- Methods for Determination the Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.Thermal Conductivity
- Application Examples
- Summary
- Introduction on the Product Guide of the NETZSCH LFA 717 HyperFlash®
- Instrument Overview and Connections
- Detector and Zoom Optics
- Front Panel
- Opening and Closing the Furnace
- Opening the Device: Internal Elements
- Standard Sample Holders
- Additional Tools
- Summary
- Introduction
- Introduction to the Flash Method
- Pulse Execution and Signal Determination
- Results Obtained from Signal Analysis
- Parker Model: AdiabaticAdiabatic describes a system or measurement mode without any heat exchange with the surroundings. This mode can be realized using a calorimeter device according to the method of accelerating rate calorimetry (ARC). The main purpose of such a device is to study scenarios and thermal runaway reactions. A short description of the adiabatic mode is “no heat in – no heat out”.Adiabatic Conditions
- Standard Model (Improved Cape-Lehman Model)
- Additional Models
- Pulse Correction
- Baseline Types
- Summary
- Introduction on influential factors
- Influence of the Graphite Spray
- Influence of the Sample Geometry
- Influence of the Atmosphere
- Influence of the Specific Heat Capacity Determination
- Summary
- Introduction on Sample Preparation
- Sample Geometry
- How to Determine the Sample Thickness
- How to Determine the Sample DensityThe mass density is defined as the ratio between mass and volume. Density
- Optimizing the Radiative Properties of the Surface
- Summary
- Introduction
- How to Fill the Detector
- Checking and Cleaning the Furnace Windows
- Placing the Sample and the Sample Holder into the Furnace
- Proteus® LFA Measurement Software: Before Measurement
- Proteus® LFA Measurement Software: Starting a Measurement
- Summary
- Introduction on evaluating a measurement
- Open the Database and the Measurement in the NETZSCH Proteus® LFA Analysis
- Thermal DiffusivityThermal diffusivity (a with the unit mm2/s) is a material-specific property for characterizing unsteady heat conduction. This value describes how quickly a material reacts to a change in temperature.Thermal Diffusivity Analysis
- Specific Heat Capacity Determination
- Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.Thermal Conductivity Determination
- Export of the Analysis Results
- Summary
- Course Summary