Laser/LIght FLash Analysis

LFA 717 HyperFlash® HT

High-temperature Light Flash Apparatus

Highlights

How Fast Is Heat Transferred?

The LFA 717 HyperFlash® HT is a state-of-the-art instrument designed to accurately measure the Thermal DiffusivityThermal diffusivity (a with the unit mm2/s) is a material-specific property for characterizing unsteady heat conduction. This value describes how quickly a material reacts to a change in temperature.thermal diffusivity of various materials. With its advanced calculation models, it is at the forefront of scientific innovation, ensuring accurate results essential for materials analysis.

  • Measurements up to 1250°C: The LFA 717 HyperFlash® HT is an advanced thermal analysis instrument that uses the latest xenon flash lamp technology to measure temperatures up to 1250°C. This innovative system eliminates the need for laser classification, making it easy to use and compliant with safety regulations.
  • Broad sample range: The LFA 717 HyperFlash® can accommodate a wide range of sample materials, including both round and square shapes. 
  • Vacuum tight furnace for controlled atmosphere: The vacuum-tight furnace is designed to create controlled atmospheres that effectively prevent OxidationOxidation can describe different processes in the context of thermal analysis.oxidation during heating processes. The vacuum-tight furnace features an internal pump that automatically evacuates the chamber prior to each measurement, maintaining a defined atmosphere for accurate results. It also provides additional ports for external pumping equipment, increasing operational flexibility. 
  • Time-saving mini-tube furnaces: With the ability to support rapid heating rates of up to 50 K/min, the four alumina mini-tube furnaces provide exceptional sample throughput across the temperature range for unmatched test speed. Each of the four sample positions is equipped with its own thermocouple, resulting in fast stabilization times. With the ability to measure ten temperature steps from RT to 1250°C in just one hour, these furnaces are designed for efficiency and precision, making them ideal for demanding applications in laboratories and research facilities.
  • Advanced corrections specifically for thin and highly conductive samples: The latest version of our analysis software introduces an enhanced analysis pulse correction feature designed for high-precision applications where exceptional time resolution is critical. This enhancement is particularly beneficial when analyzing thin and highly conductive samples, and in situations where the light pulse coincides with the thermal response of the sample.

The LFA 717 HyperFlash® HT is an essential tool for researchers and industries requiring precise thermal property measurements, making it an invaluable asset in the field of materials science.

Please accept Marketing Cookies to see that Video.

Close-up of a metallic testing device featuring labeled sections A, B, C, and D, showcasing precision engineering for analysis.

The top cover of the instrument serves as a convenient area for sample preparation and storage. It has been thoughtfully designed with four visually distinct sections, each corresponding to specific sample locations within the furnace. This innovative layout simplifies sample identification and pre-assembly, minimizes instrument downtime, and is especially beneficial in multi-user environments.

Method

Efficient Determination of Thermophysical Properties with the Light Flash Method

The Light Flash (LFA) technique is a fast, absolute, non-destructive, and non-contact method for accurate measurement of Thermal DiffusivityThermal diffusivity (a with the unit mm2/s) is a material-specific property for characterizing unsteady heat conduction. This value describes how quickly a material reacts to a change in temperature.thermal diffusivity. This innovative approach not only determines Thermal DiffusivityThermal diffusivity (a with the unit mm2/s) is a material-specific property for characterizing unsteady heat conduction. This value describes how quickly a material reacts to a change in temperature.thermal diffusivity, but also characterizes the specific heat of materials when a reference sample is used.

In the LFA process, the front surface of a plane-parallel sample is heated by a short pulse of energy. An infrared (IR) detector measures the resulting temperature change on the back of the sample. From these data, both Thermal DiffusivityThermal diffusivity (a with the unit mm2/s) is a material-specific property for characterizing unsteady heat conduction. This value describes how quickly a material reacts to a change in temperature.thermal diffusivity and specific heat can be characterized.

To calculate the Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity, these thermophysical properties are combined with the DensityThe mass density is defined as the ratio between mass and volume. density using the formula:

λ(T)=a(T)⋅cp​⋅ρ(T)

Where:

With its ability to analyze a wide range of materials at various temperatures, the LFA technique is essential for researchers and industries focused on understanding thermal properties in depth.

High-tech laboratory equipment on a sleek white base, embedded in a dynamic blue and green background, showcasing innovation.

Specifications

 LFA 717 HyperFlash® HT
Temperature RangeRT to 1250°C
Heating rate (max.)50 K/min
Measured thermal propertiesThermal DiffusivityThermal diffusivity (a with the unit mm2/s) is a material-specific property for characterizing unsteady heat conduction. This value describes how quickly a material reacts to a change in temperature.Thermal diffusivity and specific heat capacitiy (and calculation of Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity)
Furnace cooling deviceExternal chiller
Thermal DiffusivityThermal diffusivity (a with the unit mm2/s) is a material-specific property for characterizing unsteady heat conduction. This value describes how quickly a material reacts to a change in temperature.Thermal diffusivity0.01 mm2/s to 2000 mm2/s
Thermal conductivity0.1 W/(m·K) to 4000 W/(m·K)
Xenon flash lamp
 
  • Pulse energy: up to 10 Joules/pulse (variable), software-controlled
  • Pulse width: 10 to 1500 μs
ZoomOptics Patented; optimized field of view (optional, requires no mask)
Pulse mappingFor finite pulse correction and improved Specific Heat Capacity (cp)Heat capacity is a material-specific physical quantity, determined by the amount of heat supplied to specimen, divided by the resulting temperature increase. The specific heat capacity is related to a unit mass of the specimen.cp determination
IR detectors
  • InSb: RT to 1250°C
  • Detector refill device (option)
Vacuum10-4 mbar (with turbo pump)
Sample holders
  • Round and square specimen
  • Liquids, pastes, resins, powders, lamellar specimen
  • Tests under mechanical pressure
Customer support representative at a computer, smiling and engaged, highlighting NETZSCH's commitment to service excellence.


Proven Excellence in Service

At NETZSCH Analyzing & Testing, we offer a comprehensive range of services globally to ensure the optimal performance and longevity of your thermoanalytical equipment. With a track record of proven excellence, our services are designed to maximize the effectiveness of your devices, extend their lifespan, and minimize downtime. 

Unlock the full potential of your equipment with our tailored solutions, backed by years of industry expertise and innovation.

Software

Proteus® Software for LFA - Fast, efficient, and seamlessly integrated!

Three compact thermal drying machines are displayed in front of textured, fibrous material, highlighting their industrial application.

The Proteus® 64-bit software is designed to be licensed with each instrument, allowing users to simultaneously connect multiple instruments via USB or run the software on secondary installations on different computer systems. Integrated into the NETZSCH Assistant starting with version 9.5, this software suite links a wide range of NETZSCH instruments and various third-party applications into a cohesive management platform.

A significant enhancement specific to Laser Flash Analysis (LFA) is the transition from the previous database format to a new, faster SQL database format. This upgrade in data architecture results in improved modeling times and can deliver results up to 2.5 times faster while using less memory. As a result, users can now store an almost unlimited number of measurements in a single database. All standard database management functions, including import/export and data merging, are still fully supported.

3D mass-loss curve and FT-IR spectra of gases released during DCP heating, showcasing absorbance and temperature variations.

This instrument is LabV®️-ready.

Turn data into better products with LabV®—a centralized, AI-driven material intelligence platform that integrates data from this instrument and any other data sources. Designed for R&D and QC engineers, LabV® enables data-driven decision-making to drive innovation and ensure consistently high-quality results.

Related Devices

  • LFA 717 HyperFlash®

    A fast, non-contact method for determining thermal diffusivity

    • Temperature range: -100°C to 500°C
    • Simultaneous measurement of up to 16 samples
    • Broadest sample holder and sample material range
  • TCT 716 Lambda

    Determine the thermal conductivity of round solid specimens in the low- and medium-conductivity range with our Guarded Heat Flow Meter:

    • Sample mean temperature range: -10°C to 300°C
    • Thermal conductivity range: 0.1 … approx. 30 W/(m·K)
    • Two independent test stacks to measure two samples at the same time

     

  • HFM 446 LambdaMedium Eco-Line

    An exact, fast and easy-to-use instrument for measuring the low thermal conductivity, λ, of insulation materials.

    • Thermal conductivity range: 0.002 to 2 W/(m·K)
    • Metering area heat flux transducer: 102 mm x 102 mm
    • Specimen sizes (max.): 305 mm x 305 mm x 105 mm

E-Learning

Become an Expert with our Free E-Learning Courses

All NETZSCH E-Learning Basic Courses are free of charge! The content is created by our laboratory method experts, who share their personal experiences with you. Take advantage of flexible online learning, fully adapted to your training needs!

Please accept Marketing Cookies to see that Video.

LFA 717 Hyperflash - Basic Courses

Consultancy & Sales

Do you have further questions about the instrument or the method and would like to speak to a sales representative?

Service & Support

Do you already have an instrument and need technical support or spare parts?

Downloads and Media

Please accept Marketing Cookies to see that Video.

The advanced design of the LFA 717 HyperFlash® offers enhanced temperature stability, fast measurement times, and non-contact infrared detection for accurate results. Intelligent software and versatile sample holders make it adaptable for various materials − from solids to liquids.
AI Overview
An error occurred. Please try again.