Fire Testing Systems for the Building Industry

Building Material Safety and Compliance with Fire Testing Technology by NETZSCH

NETZSCH offers a comprehensive portfolio of fire testing instruments tailored to the building and construction industry, allowing for compliance with national and international fire safety standards for materials, components and full assemblies.

From insulation and wall coverings to flooring and complete assemblies, our instruments support all major international standards such as EN 13823, EN ISO 1182 and EN 9239-1, helping manufacturers meet fire safety regulations and achieve Euroclass EN 13501 certification.

We can also provide further variants and individual fire testing instruments according to customer requirements.

Our Product Portfolio

Explore the range of NETZSCH Fire Testing Instruments for the Building Industry

  • SBI 915

    Single Burning Item in accordance with EN 13823

  • KBK 917

    Small Burner Box in accordance with DIN EN ISO 11925-2

  • TBB 913

    Floor Radiant Panel in accordance with EN ISO 9239-1

  • TNB 912

    Non-Combustibility Tester in accordance with EN ISO 1182 / ASTM E2652 / IMO FTP Code Part 1

  • TDP 909 T3

    Fire Testing Device for Roofs — Test 3, Incorporating Incendiary Devices, Wind and Supplementary Radiant Heat in accordance with DIN CEN/TS 1187

  • TDP 909 T4

    Fire Testing Device for Roofs — Test 4 in Two Stages Incorporating Incendiary Devices, Wind and Supplementary Radiant Heat in accordance with DIN CEN/TS 1187

  • TSP 905

    Determination of a building product's propensity to undergo continuous smouldering (EN 16733:2016)

  • FRG 903

    Structural Cohesion Tester for Gypsum Products: A fire-resistant system with two burners in accordance with DIN EN 520.

Understanding Fire Behavior: A Four-Part Webinar Series

Discover how modern fire testing methods help you analyze material performance and generate reliable, reproducible results.

View Full Series
Colorful and textured house-shaped models made of various insulation materials, arranged on a wooden surface, showcasing thermal conductivity options.

Building Materials of Nearly Any Kind

The construction industry takes a particular interest in the fire resistance of building components and the fire reaction of building materials, exploring parameters such as flammability, flame spread, flaming droplets, combustibility, heat release, calorific value and smoke production in order to establish classification according to EN 13501.

NETZSCH fire testing devices can test the reaction to fire of nearly any material used for construction, such as facades, building materials, insulation materials, plastics and floor coverings. 

Looking for something specific? We also offer custom variants and individual fire testing solutions tailored to your needs in the construction industry.

Frequently Asked Questions

Your Benefits

30

Years of experience in Fire Testing Technology

1000

Customers in over 70 countries worldwide

50

Sales and service locations worldwide

What Makes NETZSCH Fire Testing Instruments Unique?

  • Standards compliance with EN ISO 13823, EN ISO 11925-2, EN 9239-1 and more — essential for Euroclass EN 13501 and global certification
  • Comprehensive testing portfolio covering insulation, wall panels, flooring, cables and full building assemblies
  • Flexible configuration design allowing upgrades for evolving test requirements
  • User-friendly software interface for intuitive operation and accurate measurement as well as standardized and customized reporting
  • High durability and long-term serviceability backed by NETZSCH’s global support and expertise
  • Trusted by labs and manufacturers worldwide for reliable, repeatable and regulatory-ready fire testing
  1. Customized and Integrated Solutions: NETZSCH’s wide range of instruments covering a broad application range ensures that we can meet your fire testing demands for a diverse array of materials and temperatures.
  2. Proven Excellence: Decades of experience in fire testing and a strong reputation in the market underline the reliability and advanced capabilities of our fire testing instruments.
  3. Unlimited Warranty: To emphasize the long-term availability of our services, we offer an unlimited warranty, e.g., for the SBI 915.
Long Instrument Life
High-quality instrument paired with long-term spare part availability 
Always There for You
Direct contact with your NETZSCH experts from service, lab and training 
Proven Excellence in Service
We support your NETZSCH instrument throughout its entire life cycle

Applications for the Building Industry

  • SBI 915: The Single Burning Item (EN 13823) is used to assess the reaction to fire of building materials like wall and ceiling panels, insulation, coatings, and facade components. It simulates a single burning item igniting a corner of a room, measuring parameters including lateral flame spread, heat release, smoke generation, flaming droplets, and gas output.
  • KBK 917: The Single-Flame Source Test Device (ISO 11925‑2 / EN ISO 11925‑2) is designed for ignitability testing of materials such as small-scale facade panels or claddings.
  • TBB 913: The Flooring Radiant Panel Tester (EN ISO 9239‑1 / ASTM E648) evaluates critical radiant flux, flame propagation, and smoke DensityThe mass density is defined as the ratio between mass and volume. density over time to classify flooring materials such as carpets, vinyl, wood, or laminate in corridor fire scenarios typical in public buildings.
  • TNB 912: The Non‑Combustibility Test Device (EN ISO 1182 / ASTM E2652 / IMO FTP Code Part 1) tests whether homogeneous or composite building products contribute to fire progression ‒ used for Euroclasses A1 or A2 via furnace heating to a defined temperature LEVEL, measuring mass loss, temperature increase and duration of flaming.
  • TDP T3 & TDP T4: The NETZSCH Roof Testing Systems (DIN CEN/TS 1187) simulate fire on realistic multi-layer roof assemblies, with wind and radiant heat to assess flame spread, structural penetration, droplet fallout, and glowing behavior (TDP T3, method 3). With the TDP T4 (method 4), a two-stage test is executed ‒ initial burner exposure, then wind plus radiant heating ‒ to evaluate burn-through, flame spread radius, and dropping behavior across full roof systems. It is also possible to combine the two systems into one instrument.
  • TSP 905: The Smoldering / Glow Fire Test is used for smoldering behavior analysis of materials under low-oxygen, sustained heating conditions ‒ relevant for products like insulation, upholstery or composite wall coverings that may glow or smolder without open flame.

Why Fire Testing Systems Matter for the Building Industry

NETZSCH fire testing systems are designed to evaluate the burning behavior of construction materials, such as insulation, wall panels, flooring, and roofing according to international standards.

These systems provide reliable data on essential factors such as flame spread, heat release, smoke development, and smoldering behavior. This information is crucial for product classification (EN 13501) and product development, as well as regulatory approval and building safety.

Are you interested in fire testing devices for other industries or applications?

Feel free to take a look at our entire range of fire testing systems.

Media and Training

Videos that may be interesting to you

Please accept Marketing Cookies to see that Video.

In preventive fire protection, the proper selection of materials and components is essential in preventing fires from starting or spreading. In this webinar, we will present fire testing equipment according to German, European and International standards.

Please accept Marketing Cookies to see that Video.

Especially for safety reasons, it is important to understand the behavior of supposedly non-combustible materials under fire conditions: What happens with the building material? How durable are the building constructions? We’ll show you how to use the Kinetics Neo software to predict material behavior under fire conditions.

Consultancy & Sales

Do you have further questions about our instruments or the method? Would you like to speak to a sales representative?

Service & Support

Do you already have an instrument and need technical support or spare parts?

FAQs about NETZSCH Service