Highlights
System for the reaction of floorings to fire tests – determination of the burning behavior using a radiant heat source in accordance with EN ISO 9239-1
The TBB 913 from NETZSCH TAURUS Instruments GmbH is easy to operate, offering innovative control and data acquisition options in an intuitive format with ample user guidance. The high-resolution color touch display on the “TBB Control“ cabinet allows for measuring and control with the integrated Single Board Computer, Windows 10 IoT Enterprise 2019 LTSC operating system and TBB software. There is thus no longer any need for manual controls such as switches,
controllers or buttons; the status of the testing system is clearly displayed and the systems prevents any critical operating errors.
Well thought-out details along with the use of high-quality materials guarantee the TBB 913 test system a long product life and a low degree of wear and tear.

Method
Test Setup
The floor covering to be tested is placed horizontally under a gas-heated radiator. The defined heat flux profile simulates the heat load on the floor in the event of a fire.
Test Chamber
The stainless steel test chamber has a carrier plate with specimen holder, which in turn is fitted with a pull-out. The flap with viewing window at the front of the test chamber allows the test process to be observed.

Understanding Fire Behavior: A Four-Part Webinar Series
Specifications
| Measurement method | Determination of the burning behavior of floorings in accordance with EN ISO 9239-1 |
| Test chamber |
|
| Sample holder |
|
| Gas heater | Surface gas burner, steel/silicate, intalle in the test chamber |
| Ignition burner |
|

Proven Excellence in Service
At NETZSCH Analyzing & Testing, we offer a comprehensive range of services globally to ensure the optimal performance and longevity of your thermoanalytical equipment. With a track record of proven excellence, our services are designed to maximize the effectiveness of your devices, extend their lifespan, and minimize downtime.
Unlock the full potential of your equipment with our tailored solutions, backed by years of industry expertise and innovation.
Software
Graphical and Numerical Display of all Test Results
- Freely configurable display of results as chart, diagram, text or bar
- 16 freely configurable windows depending on display format
- Test results can be displayed on separate screens
Individual Configuration of Measurement Points
- Allocation of name, measurement range, and correction value for each channel
- Allocation and analysis of thresholds for each channel
- Display of all calculated values according to standar
Test Report
- Input mask for all test-relevant data according to standard
- Test report printout according to DIN EN 9239-1 with graphical and numerical display options
- Display of current calibration data as part of the test report
- Copying of report data (texts/ graphics) to clipboard for further use in user-specific documents
- Export of test report to text file

Related Devices

Consultancy & Sales
Do you have further questions about the instrument or the method and would like to speak to a sales representative?
Service & Support
Do you already have an instrument and need technical support or spare parts?












