batteries

Lithium Cobalt Oxide Cathode — Thermal Stability

Lithium cobalt oxide is widely used in cathodes for lithium ion batteries. The stability of the cathode material is an important factor in designing inherently safer, high performing battery systems. 

In this example, a sample of delithiated LiCoO2 material was removed from a Coin Cell ModuleA calorimeter module being part of the Multiple Module Calorimeter (MMC) allowing for scanning and isothermal tests of complete coins of variable size. The DSC-like twin design gives a differential signal of the heat signature during a heating ramp or charging and discharging of batteries.coin cell and placed in a NETZSCH STA 449 F1 Jupiter®®coupled to the QMS 403 Aëolos® Quadro for analysis. The cathode material shows several discrete Decomposition reactionA decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. decomposition steps at increasing temperature rates. With the aid of the attached mass spectrometer it is much easier to understand the Decomposition reactionA decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. decomposition pathways and the underlying structure of the cathode material after cycling.

Thermogravimetric analysis graph of lithium cobalt oxide cathode stability, showing mass loss and ion current at varying temperatures.