NETZSCH TG 309 Libra® instrument featured, showcasing its advanced thermogravimetric analysis capabilities for precise measurements.
Learn, Apply, Achieve.

TG 309 Libra® Select
Basic Course

Language: English - Duration: 134 Min.

This Online course explains the

Course Information

  • Language: English
  • Total Course Duration: 134 Min.
  • Duration of use: unlimited
  • Price: free of charge

Syllabus

  • Introduction of the speaker and the agenda
  • Introduction on the Product Guide of the NETZSCH TG 309 Libra® Select
  • Device overview
  • LED status bar
  • Open the furnace
  • Eco mode
  • Accessories and Equipment
  • Changing the sample carrier
  • Introduction on the theory
  • Definition of TGA
  • Measurement Setup & Raw Signal
  • Characteristic values and application fields
  • Examples
  • Summary of the theory
  • Introduction on influential factors
  • Influence of the Buoyancy and Friction Effect
  • Influence of the carrier gas
  • Influence of the heating rate
  • Influence of the crucible
  • Influence of the sample size and mass
  • Summary of the influential factors
  • Introduction on Sample Preparation
  • Sample Preparation of granules
  • Sample Preparation of samples in powder form
  • Sample Preparation of foils
  • Sample Preparation of rubber
  • Sample Preparation of liquids
  • Introduction on starting a measurement
  • Correction measurments
  • Start a measurement using the NETZSCH Proteus® ExpertMode
  • Start a measurement using the NETZSCH Proteus® SmartMode
  • Create a method using the NETZSCH Proteus® ExpertMode
  • Create a method using the NETZSCH Proteus® SmartMode
  • How to program the Automatic Sample Changer (ASC)
  • Introduction on evaluating a measurement
  • Evaluation of thermal effects - Theory
  • Manual evaluation
  • Automatic evaluation
  • Introduction to calibration
  • Balance calibration
  • Automatic calibration for calibrating the temperature
A middle-aged man and a young woman collaborate at a table, analyzing data on a tablet in a modern office setting.

Consultancy & Sales

Do you have further questions about the instrument or the method? Would you like to speak to a sales represenative?

Service & Support

Do you already have a NETZSCH instrument and need technical support or spare parts?

Smiling customer support representative in a modern office, engaged in a conversation while working on a computer.
Two lab technicians analyze thermal analysis data on a computer screen, showcasing NETZSCH software in a laboratory setting.

Academy & Training

Would you like us to provide online live training or on-site training at the laboratory to meet your specific requirements?

AI Overview
An error occurred. Please try again.