Food
Thermal Analysis and Rheology Solutions for the Analysis of Foods
Food should not only serve to satisfy hunger, but also contribute to our well-being and health. And for some of us, it can mean even more: fun, happiness, adventure, and sociability. In any case, we all need balanced nutrition, including all the necessary proteins, fats, vitamins, trace elements and dietary fibers – and, of course, it’s best when it’s tasty too.
ENJOY YOUR MEAL!
In order to ensure high food quality, to find suitable ingredients and the right preparation techniques, and to provide good mouthfeel – or in other words, to adapt it to your needs – a variety of analytical methods are typically applied. Amongst them are Thermal Analysis and Rheometry by NETZSCH. They play an important role in characterizing raw materials and food additives, in determining the appropriate food consistency, and in optimizing manufacturing processes.
How Can You Benefit from Thermoanalytical and Rheological Tests?
Characteristic physicochemical properties of food ingredients or their changes during heating or cooling can be measured using various thermoanalytical techniques such as Differential Scanning Calorimetry (DSC), Thermogravimetric Analysis (TGA), and Simultaneous Thermal Analysis (STA). DSC identifies and determines the Température de Transition VitreuseThe glass transition is one of the most important properties of amorphous and semi-crystalline materials, e.g., inorganic glasses, amorphous metals, polymers, pharmaceuticals and food ingredients, etc., and describes the temperature region where the mechanical properties of the materials change from hard and brittle to more soft, deformable or rubbery.glass transition and/or Melting Temperatures and EnthalpiesThe enthalpy of fusion of a substance, also known as latent heat, is a measure of the energy input, typically heat, which is necessary to convert a substance from solid to liquid state. The melting point of a substance is the temperature at which it changes state from solid (crystalline) to liquid (isotropic melt).melting point of solid, semi-solid or liquid food components as well as the polymorphic behavior, for example, of fats. By means of TGA, the thermal and oxidative stability of substances as well as the composition (volatiles, residues from extraction, ash content, etc.) of foodstuff can be studied.
Characterization of the rheological behavior of individual components and of final products goes far beyond flow curves and viscosity. Viscoelastic properties, yield ContrainteLa Contrainte est définie par un niveau de force appliquée sur un échantillon d’une section bien définie. (Contrainte = force/surface). Les échantillons qui possèdent une section rectangulaire ou circulaire peuvent être comprimés ou étirés. Les matériaux élastiques comme les élastomères peuvent être étirés jusqu’à 5 à 10 fois leur longueur initiale.stress, gelation properties, and flow properties of liquids and semi-solids under relevant shear rates are examples of rheological application in the food field. You can even simulate the chewing process in the mouth by using the so-called mastication mode. The Kinexus rotational rheometer and the Rosand high-pressure capillary rheometer cover the broadest shear rate range available on the market, and are indispensable to the research, development and quality control of foods.