Fourier Transform Infrared Spectroscopy (FT-IR)

STA 319 Jupiter® Coupled to Bruker's INVENIO via Transfer Line

The Perfect STA-FT-IR Coupling Solution 

Highlights

Thermal Analysis Plus FT-IR - More Than Just the Sum of Its Parts

The NETZSCH STA 319 Jupiter® with FT-IR coupling combines simultaneous thermal analysis — TGA and DSC signals from one and the same sample — with advanced gas phase detection via FT-IR spectroscopy. This powerful setup enables a deeper understanding of decomposition, oxidation, phase transitions, and other thermal processes by correlating mass changes and thermal effects with the identification of gases evolved upon heating.

With its robust, water-cooled ceramic furnace, advanced top-loading microbalance, and vacuum-tight design, the STA 319 Jupiter® provides reliable measurements under defined atmospheric conditions. When combined with a heated transfer line, evolved gases can be transferred safely and efficiently from the furnace outlet to the FT-IR gas cell, supporting accurate and condensation-free gas analysis, even for reactive or condensable species.

Coupled with the Bruker INVENIO FT-IR platform, the system delivers high spectral resolution and sensitivity across a broad range of applications, including polymers, chemicals, pharmaceuticals, life science materials, and inorganics. The seamless integration of NETZSCH Proteus® and Bruker OPUS software ensures synchronized data acquisition, allowing users to directly correlate TGA and DSC events with specific gas species and reaction mechanisms.

This modular STA solution opens new possibilities in simultaneous thermal analysis and hyphenated techniques. By combining thermal effects, mass changes, and evolved gas analysis in one workflow, the STA 319 Jupiter® provides comprehensive insights into material behavior — from routine quality control to advanced R&D applications.

Method

Fourier Transform Infrared (FT-IR) Spectrometers Coupled to Thermal Analysis

Thermal analysis provides ideal tools for the characterization of a variety  of organic and inorganic solids and liquids. Thermodynamic transitions, thermal stability, decomposition, and chemical reactions can be detected and quantified with high accuracy over a broad temperature range.

In some cases, however, information about the type of evolved gases is needed to gain a clearer understanding of the chemistry behind the processes. Coupling  thermal analysis with powerful infrared spectroscopy for gas analysis bridges this gap. It allows for a deeper insight into the material’s behavior and provides a spectral fingerprint of the gases evolved from the sample when heated..

The Proteus® software for thermal analysis and the OPUS software for FT-IR measurements are seamlessly integrated to enable efficient Thermal Analysis-to-FT-IR coupling. The temperature and time correlations of all experimental data are carefully preserved throughout the process.

Infrared spectroscopy

La spectroscopie infrarouge est une technique classique reposant sur l'absorption du rayonnement infrarouge par les VibrationsUn processus mécanique d'oscillation est appelé vibration. La vibration est un phénomène mécanique par lequel des oscillations se produisent autour d'un point d'équilibre. Dans de nombreux cas, la vibration est indésirable, car elle gaspille de l'énergie et crée des sons indésirables. Par exemple, les mouvements vibratoires des moteurs, des moteurs électriques ou de tout autre dispositif mécanique en fonctionnement sont généralement indésirables. Ces vibrations peuvent être causées par des déséquilibres dans les pièces rotatives, des frottements inégaux ou l'engrènement des dents d'un engrenage. Une conception soignée permet généralement de minimiser les vibrations indésirables.vibrations des liaisons moléculaires. Cette absorption se produit lorsque les liaisons vibrent selon des modes spécifiques. Cependant, seules les VibrationsUn processus mécanique d'oscillation est appelé vibration. La vibration est un phénomène mécanique par lequel des oscillations se produisent autour d'un point d'équilibre. Dans de nombreux cas, la vibration est indésirable, car elle gaspille de l'énergie et crée des sons indésirables. Par exemple, les mouvements vibratoires des moteurs, des moteurs électriques ou de tout autre dispositif mécanique en fonctionnement sont généralement indésirables. Ces vibrations peuvent être causées par des déséquilibres dans les pièces rotatives, des frottements inégaux ou l'engrènement des dents d'un engrenage. Une conception soignée permet généralement de minimiser les vibrations indésirables.vibrations qui entraînent une variation du moment dipolaire peuvent interagir avec la lumière infrarouge. C'est pourquoi la plupart des substances produisent un spectre caractéristique, tandis que les molécules homonucléaires — telles que l'O₂ et le N₂ — ou les gaz nobles ne présentent pas de bandes d'absorption infrarouge fondamentales, en raison de l'absence de variation du moment dipolaire lors des VibrationsUn processus mécanique d'oscillation est appelé vibration. La vibration est un phénomène mécanique par lequel des oscillations se produisent autour d'un point d'équilibre. Dans de nombreux cas, la vibration est indésirable, car elle gaspille de l'énergie et crée des sons indésirables. Par exemple, les mouvements vibratoires des moteurs, des moteurs électriques ou de tout autre dispositif mécanique en fonctionnement sont généralement indésirables. Ces vibrations peuvent être causées par des déséquilibres dans les pièces rotatives, des frottements inégaux ou l'engrènement des dents d'un engrenage. Une conception soignée permet généralement de minimiser les vibrations indésirables.vibrations.

DSC heat-flow curve (blue) contrasts with temperature (red) trends, illustrating thermal analysis results over time.
NETZSCH Tech Talk features innovative thermal analysis solutions, including Differential Scanning Calorimetry and Dynamic-Mechanical Analysis. Join experts on December 5, 2023, to explore advancements in materials characterization.
Race car pit stop with a red car surrounded by crew in orange uniforms, showcasing high-speed repair and teamwork.
Absorbance spectrum graph displaying peaks between 1000 cm⁻¹ and 4000 cm⁻¹, illustrating material analysis data.

Working principle of a FT-IR spectrometer 

An infrared light beam, depicted in the diagram as coming from the source on the right, is split into two paths by a beam splitter. One path is directed toward a fixed mirror and reflected, while the other is reflected by a moving mirror.

After reflection, the two beams are recombined and interfere with each other. The resulting interference pattern depends on the distance between the two mirrors — which changes as the moving mirror shifts position — and the frequencies present in the beam.

This process generates an interferogram, a signal typically characterized by a central burst and flat wings. The central burst occurs when both mirrors are equidistant from the beam splitter, allowing all frequencies to interfere constructively.

Finally, the interferogram is mathematically transformed into a spectrum using a Fourier Transform, revealing the sample’s infrared absorption characteristics.

Netzsch Bruker logo featuring blue and green shapes with the tagline "Cooperation since 1993," symbolizing innovation and collaboration.

Over 30 Years of Successful Cooperation

For over 30 years, NETZSCH and Bruker have collaborated to provide integrated solutions for thermal analysis and gas analysis. This longstanding partnership combines NETZSCH's expertise in thermal analysis with Bruker's leadership in FT-IR technology, offering customers reliable, high-quality systems tailored to their needs. Together, we deliver innovative, user-friendly solutions from a single source, ensuring seamless operation and exceptional support.

Advantages of our Cooperation at a Glance:

  • Seamless integration: Optimized coupling of NETZSCH thermal analyzers with Bruker FT-IR spectrometers for reliable and efficient evolved gas analysis.
  • Proven expertise: Decades of joint experience ensure high-quality, innovative solutions tailored to customer needs.
  • Single-source convenience: Fully compatible systems with comprehensive support from both partners.
  • Enhanced performance: Precise coordination of instruments delivers accurate and reproducible results.
  • Continuous innovation: Collaboration fosters the development of cutting-edge technologies and features for advanced analysis.
  • Effortless Compatibility with Bruker's OPUS Software: At NETZSCH, we offer seamless compatibility with Bruker’s OPUS software, allowing for a smooth workflow between both systems. This ensures an integrated and efficient experience, making the most out of both instruments.

Veuillez accepter les cookies Marketing pour regarder la vidéo.

Learn, how Bruker Optics and NETZSCH Analyzing & Testing have been collaborating since 30 years and how the FT-IR technique help solving your challenges.

Specifications

Gas cell volume and length
11.8 ml/123 mm
Temperature of transfer line
max. 400°C
Detector
DLaTGS or MCT 
Analytical laboratory equipment showcasing advanced technologies for precise testing and analysis in scientific research.

Wave number range:
FT-IR: 8000 cm-1 to 340 cm-1
Coupling: 4400 cm-1 to 600 cm-1

Resolution:
better than 0.4 cm-1

Furnace adaptor:
max. 400°C

Transfer line material:
Stainless steel (exchangeable)

Window material gas cell:
KBr

Acessories

The automatic sample changer (ASC) similarly handles routine measurements in quality control as well as requirements for research and development. It works around the clock to free your time for other challenges and allows you to make optimal use of the coupling even during the weekend. Of course, each sample can be assigned a different measurement and evaluation program. Easy-to-understand input fields lead you through the programming of a series of measurements. Unplanned analyses can also be inserted into a pre-programmed series of measurements already in progress.

High-precision lab equipment with a touchscreen interface, designed for materials testing and analysis.

Find out even more about the Transfer Line Coupling

Représentant du service clientèle devant un ordinateur, souriant et engagé, soulignant l'engagement de NETZSCH en faveur de l'excellence du service.


Un service d'excellence éprouvé

À NETZSCH Analyzing & Testing, nous offrons une gamme complète de services à l'échelle mondiale pour assurer la performance optimale et la longévité de votre équipement thermoanalytique. Avec un historique d'excellence prouvé, nos services sont conçus pour maximiser l'efficacité de vos appareils, prolonger leur durée de vie et minimiser les temps d'arrêt.

Exploitez tout le potentiel de votre équipement grâce à nos solutions sur mesure, soutenues par des années d'expertise et d'innovation dans l'industrie.

Software

Bruker OPUS and NETZSCH Proteus® – Unrivaled Combination for Maximum Ease of Use 

3-D analysis view in OPUS software displaying straw pyrolysis test results, including TGA curve and spectrum plots.
Screenshot of the OPUS software during evaluation of a straw pyrolysis test: Multi-window presentation containing a 3-D diagram (x-y-z view, including TGA curve and temperature information from the thermal analysis system), a 2-D plot (topview on the 3-D cube) and a spectrum window, representing the spectrum at the position of the red line within the 3-D diagram
Temperature-scaled plot displaying TGA, DTG, and Gram-Schmidt curves with methane, water, and carbon monoxide traces.
Screenshot of the Proteus® software during evaluation of the same straw experiment: Temperature-scaled plot of the TGA and DTG curves together with the Gram-Schmidt plot and the calculated traces of methane, water and carbon monoxide (course of the absorption intensity of a specific band)

The alliance between the NETZSCH Proteus® software and the OPUS FT-IR software is based on synchronized data exchange, enabling coordinated operation of the coupled systems. Measurements are started via the NETZSCH Proteus® software, which simultaneously triggers data acquisition in OPUS. Users only need to input the command for measurement start and data acquisition once; both OPUS and Proteus® will then operate with the predefined parameters. Online data collection is fully synchronized, ensuring precise time and temperature correlation between all signals from the two coupled instruments during evaluation. The two software packages can be operated from a single computer, giving users access to the full range of data evaluation and results display options in either environment at any time.

Find out even more about the software:

  • Full software integration – online data exchange between the two instrument software packages during the running experiment
  • Seamless instrument control and measurement definition for STA and FT-IR, with thermal analysis parameters controlled by Proteus® software
  • Segmental activation or deactivation of the FT-IR coupling with one mouse click
  • Automatic saving of data sets for both measurements (STA and FT-IR) with identical file names, but different extensions, in the same directories
  • Conjoint presentation of the Gram-Schmidt plot plus up to 30 pre-selected traces together with TGA and DSC curves in Proteus®® software during the experiment
  • Online evaluation  of STA measurements, including TGA, DSC and FT-IR data, already during the running measurement
  • Trace calculations with evaluation of characteristic temperatures and peak areas together with TGA and DSC curves
  • Combined analysis graphics of thermal analysis and FT-IR signals
  • Multi-component search in OPUS
  • Identification by various gas phase libraries, e.g., the TGA-FT-IR library of polymers by NETZSCH

Related Devices

  • PERSEUS® TG 309 Libra® avec accouplement direct
    • Pas d'azote liquide nécessaire
    • Pas de ligne de transfert séparée
    • Conception peu encombrante
    • Facilité d'utilisation grâce au passeur automatique d'échantillons
    • Analyse des gaz évolués jusqu'à une température d'échantillon de 1100°C
    • Débit d'échantillons élevé grâce à large ASC et au refroidissement rapide du four
    • Intégration transparente des logiciels Proteus® et OPUS
  • PERSEUS® STA 509 Jupiter® avec accouplement direct
    • Pas besoin de ligne de transfert externe ou d'adaptateur de couplage
    • Détection simultanée des changements de masse, des espèces gazeuses et des signaux DSC
    • Températures d'échantillon jusqu'à 2000°C
    • Encombrement minimal grâce à l'Alpha II de Bruker intégré
    • Intégration transparente des logiciels Proteus® et OPUS

  • STA 509 Jupiter® couplé à l'INVENIO de Bruker via une ligne de transfert
    • Transport optimisé des gaz à travers une ligne de transfert chauffée
    • Analyse des gaz évolués à des températures allant jusqu'à 2000°C
    • Prise en charge des signaux TGA et DSC pour une analyse approfondie
    • Flexibilité maximale dans le positionnement de l'instrument
    • Idéal pour les environnements multi-utilisateurs et de recherche
    • Intégration transparente des logiciels Proteus® et OPUS

Consultancy & Sales

Do you have further questions about the instrument or the method and would like to speak to a sales representative?

Service & Support

Do you already have an instrument and need technical support or spare parts?

Downloads and Media

AI Overview
An error occurred. Please try again.