Seminar

How to Optimize Your Polymer Workflow with Thermal Analysis and Rheology

BRUKER INVENIO spectrometer system with gas cell for EGA and thermal analysis, showcasing advanced FT-IR capabilities.
18.05.2023 15:30 – 21:30
Dearborn, MI USA
Registration is closed, we're at capacity.

Attendees will be introduced to the basic techniques of thermal analysis and rheology, including but not limited to DSC, TGA, STA, LFA, rotational and capillary techniques.  An overview of the theory will be given, followed by instrumentation basics as well as how instrument configuration can impact results. Finally, real world application examples will be discussed for each characterization technique. There will be ample time for attendees to discuss their applications with our experts.

  • Detailed Schedule is below


Registration is closed, we're at capacity. Please email us for questions:

Location

Doubletree Hotel
Dearborn, MI
5801 Southfield Fwy
Detroit, MI 48228
Phone: (313) 336-3340

Date and time

18  May 2023
9 AM - 3:30PM

Registration

Registration is closed, we're at capacity.

AGENDA

 

How to Optimize Your Polymer Workflow with

Thermal Analysis and Kriechen (Rheologie)Creep is one of the earliest “controlled stress” rheometer tests that quite literally “creeps” the material, i.e. we measure over a relatively prolonged period the small movement (the creep defined as creep compliance, J) of the sample by applying a small constant stress.Rheology 

 

 
 

 Thursday, May 18 , 2023

 
8:45 am - 9:15 am Arrival and Continental Breakfast  
9:15 am - 9:30 am Welcome and Introduction to NETZSCHDr. Natalie Rudolph, Peter Vichos
9:30 am - 10:30 am Quality Control and Failure Analysis by DSC (Differential Scanning Calorimetry) 
10:30 am -10:45 am ***BREAK*** 
10:45 am -12:00 am Plastics in the Flow by Rotational and Capillary RheologyDr. Natalie Rudolph
12:00 am-12:30 pm Compositional Analysis of Compounds by TGA (Thermogravimetric Analysis) - An Overview 
12:30 pm -1:45 pm ***LUNCH*** 
1:45 pm - 2:15 pm Characterization of the Viscos-elastic Properties of Polymers by DMA (Dynamic Mechanical Analysis)Dr. Natalie Rudolph
 2:15 pm - 3:00 pmCure Monitoring of Thermosetting Resins by DEA (Dielectric Analysis)Dr. Natalie Rudolph
   3:00 pm  Wrap-up and DiscussionPeter Vichos 
 

* Participants receive a USB drive containing all Presentation Material and Product Literature

 

Whether you are a complete beginner, or an expert planning to bring your most challenging application questions, we look forward to seeing you there

Dr.-Ing. Natalie Rudolph
Dr.-Ing. Natalie Rudolph
Division Manager Polymer
AI Overview
An error occurred. Please try again.