Blog
Career
Contact
English
German
English (Australia)
English (USA)
Spanish
French
Italian
Japanese
Korean
Polish
Portuguese (Brazil)
Russian
Group
Proven Excellence.
Analyzing & Testing
Devices for thermal analysis, rheology as well as fire testing devices
Pumps & Systems
Pumping Solutions individually tailored to your requirements
Grinding & Dispersing
Extensive range of machines for grinding and dispersing
Blog
Career
Contact
Products
Differential Scanning Calorimeter (DSC) / Differential Thermal Analyzer (DTA)
Simultaneous Thermal Analyzer (STA/TGA-DSC)
Thermogravimetric Analyzer (TGA)
Dilatometer (DIL)
Thermomechanical Analyzer (TMA)
Dynamic Mechanical Analyzer (DMA)
Multiple Module Calorimeter (MMC)
Accelerating Rate Calorimeter (ARC)
Dielectric Analyzer (DEA)
Light/Laser Flash Analyzer (LFA)
Time Domain Thermoreflectance Analyzer (TDRA)
Seebeck Analyzer (SBA)
Evolved Gas Analyzer (EGA, coupled to Thermal Analyzer)
Software
Rheometers
Heat Flow Meter (HFM) / Guarded Hot Plate/Pipe (GHP) / HotBox Test Chambers (TDW)
Fire Testing Systems
Refractory Tester
Applications
Polymers
Adhesives & Sealants
Batteries
Biomass
Building Materials
Ceramics & Glass
Inorganics
Metals & Alloys
Organics
Pharma
Photovoltaics
Thermal Insulation
Thermoelectric
Training & Know-how
NETZSCH Academy
Literature & Digital Media
Glossary
Training & Seminars
Tips & Tricks
Service & Support
FAQ Service
Technical Service
Repair Service
On-Site Service
Customer Magazine Onset
Service in Regulated Areas
Certificates
Applications Advisory Service
Material Safety Data Sheets
Mailing Service
Warranty Terms and Terms and Conditions of Purchase
Contract Testing
Methods
Glossary
Events &
Seminars
ProductsDifferential Scanning Calorimeter (DSC) / Differential Thermal Analyzer (DTA)Simultaneous Thermal Analyzer (STA/TGA-DSC)Thermogravimetric Analyzer (TGA)Dilatometer (DIL)Thermomechanical Analyzer (TMA)Dynamic Mechanical Analyzer (DMA)Multiple Module Calorimeter (MMC)Accelerating Rate Calorimeter (ARC)Dielectric Analyzer (DEA)Light/Laser Flash Analyzer (LFA)Time Domain Thermoreflectance Analyzer (TDRA)Seebeck Analyzer (SBA)Evolved Gas Analyzer (EGA, coupled to Thermal Analyzer)SoftwareRheometersHeat Flow Meter (HFM) / Guarded Hot Plate/Pipe (GHP) / HotBox Test Chambers (TDW)Fire Testing SystemsRefractory Tester
ApplicationsPolymersAdhesives & SealantsBatteriesBiomassBuilding MaterialsCeramics & GlassInorganicsMetals & AlloysOrganicsPharmaPhotovoltaicsThermal InsulationThermoelectric
Training & Know-howNETZSCH AcademyLiterature & Digital MediaGlossaryTraining & SeminarsTips & Tricks
Contract TestingMethodsGlossary
Events & Seminars
Service & Support
FAQ Service
Technical Service
Repair Service
On-Site Service
Customer Magazine Onset
Service in Regulated Areas
Certificates
Applications Advisory Service
Material Safety Data Sheets
Mailing Service
Warranty Terms and Terms and Conditions of Purchase

Glossary

Stress-Strain Behavior

The figure shows a typical StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress-StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain plot of an elastomer.  

The most noticeable feature is its non-linearity, which takes place from A to E. Only in the range from 0 to A (normally the corresponding strain reaching the limit of linearity is not larger than 1 %), the StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress/strain ratio results in a constant number: the Elastic modulusThe complex modulus (elastic component), storage modulus, or G’, is the “real” part of the samples the overall complex modulus. This elastic component indicates the solid like, or in phase, response of the sample being measurement. Elastic modulus.
 This behavior can be measured with the DMA EPLEXOR®®.

Lab Contact

Related Methods

  • Dynamic Mechanical Analysis (DMA)