applications

Batteries

For the development, the manufacturing and the use of the most varied of batteries, knowledge of the thermal properties, safety assessment and life cycle plays a decisive role.

The primary objectives of current battery design strategy include a long service life, a multitude of complete charging and discharging cycles, and a continuous release of the stored electric energy. By means of modern thermo analytical and calorimetry measuring methods, it is possible to select and optimize the materials for anode, cathode, electrolytes, separators and to optimize the cells build with these materials. The three main battery components (anode, cathode, electrolyte etc) all jointly contribute to thermal instability. Additionally, the cell voltage exasperates the thermal instability problems. Once those cells are assemble in new battery stacks, calorimetry is the best solution to study hazard & thermal safety of, i.e. lithium ion batteries. Accelerated Rate Calorimeter (ARC®) enable not only to analyze life cycle efficiency and performance of these batteries, it allows also to run abuse testing: shorting, overvoltage, nail penetration and crunch tests.

The design loop of new batteries can be summarized as follow, from raw material testing, cell design, abuse testig to recycling.

NETZSCH is the only supplier of solutions for each of these different steps.

The NETZSCH Group provides total solution for battery applications.

Battery Testing by means of Thermal Analysis and Rheology

Select your method according to your needs

DSCTGSTAEGADILLFAMMCARC®KinexusKinetics Neo
Battery Raw Material++++++++++++++n.a.n.a.++++
Components
(Anodes / Cathodes / Separators / PCT)
++++++++++++++++++
Cell Designn.a.n.a.n.a.n.a.n.a.+++n.a.+++
Performance & Safety++++++++++n.a.n.a.++++++
Life Cyclen.a.n.a.n.a.n.a.n.a.n.a.n.a.+++
Recycling+++++++++++++++n.a.n.a.++

Considerable efforts are currently being channeled into battery research. The target is to find new materials enabling better energy and power DensityThe mass density is defined as the ratio between mass and volume. density as well as more efficient energy storage. This requires sophisticated instrumentation for the production and characterization of materials such as anode and cathode materials, separators, electrolytes, boundary layers.

If you develop or produce raw materials for the battery industry, you may want to:

Once new raw materials have been selected, the design of electrodes leads to questions related to their manufacturing and use. We at NETZSCH bring a full set of instruments to characterize those electrodes, separators, electrolytes.

If you develop or produce battery components, you may want to:

Every application has different performance requirements and constraints. No one chemistry is the right solution for all applications. Changes in components may be required as the needs of the application change and as new technologies become available. A well-designed thermal management system is critical to the life and performance of battery cells. As electrochemical devices, batteries’ performance and lifespan are affected by temperature. High temperatures increase side reactions and Decomposition reactionA decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. decomposition of interfacial boundaries, shortening battery life and increasing battery replacement costs.

Development of precisely-calibrated battery systems rely on accurate measurements of heat generated by battery cells during the full range of charge/discharge cycles, as well as the behavior during abuse testing.

If you develop or produce battery cells, you may want to:

When a battery is charged or discharged, heat is generated and absorbed. IsothermalTests at controlled and constant temperature are called isothermal.Isothermal calorimetry in connection with battery cyclers is a smart way to charaterize the heat flow, and therefore to analyze the battery life cycle. Temperature, charge/discharge rates and the Depth of Discharge each have a major influence on the cycle life of the cells. New Battery designs (choice of new material and/or new assembly of components) can be evaluated thanks to calorimetry mesurement. The Accelerating Rate Calorimeter (ARC®) allows testing in an IsothermalTests at controlled and constant temperature are called isothermal.isothermal mode in complete safety for the instrument and the operator.

If you analyze a battery performance, you may want to:

  • Collect accurate heat generation data from battery module
  • Run in complete safety a charge/discharge test without taking any risk to destroy the instrument
  • Understand if there has been any deterioration in original performance
  • Obtain a performance signature over time to evaluate the effects of aging and cycling
  • Evaluate physical and electrochemical design changes that could lead to better battery module

When batteries have reached their end of life, they are collected to be either reconditioned or reused in less demanding application, or the battery is disassembled and each single component is recycled. Batteries are built with assemblies of different polymers, oxides, metallic materials. Thermal analysis is useful characterization tools in this field.

If you are in the business of battery recycling, you may want to:

  • Evaluate the feasibility of physical separation of its main components
  • Evaluate the efficiency of the liberation of different components when the battery is converted into fragments
  • Characterize each components of the battery, when fragmented
  • Understand material behavior of the recycled materials stability as a function of temperature

Lithium ion battery technology offers many advantages in portable power application but one major concern is safety. Battery developers need tools which allows them to design safer batteries without compromising performance.

By means of a “Worst-Case ScenarioRelated to a chemical reactor, a worst-case scenario is the situation where temperature and/or pressure production caused by the reaction runs out of control.worst-case scenario” (Thermal runawayA thermal runaway is the situation where a chemical reactor is out of control with respect to temperature and/or pressure production caused by the chemical reaction itself. Simulation of a thermal runaway is usually carried out using a calorimeter device according to accelerated rate calorimetry (ARC).thermal runaway) scheme, AdiabaticAdiabatic describes a system or measurement mode without any heat exchange with the surroundings. This mode can be realized using a calorimeter device according to the method of accelerating rate calorimetry (ARC). The main purpose of such a device is to study scenarios and thermal runaway reactions. A short description of the adiabatic mode is “no heat in – no heat out”.adiabatic calorimetry can provide many pertinent answers, including the temperature at which lithium ion cells or their components can exhibit a highly ExothermicA sample transition or a reaction is exothermic if heat is generated.exothermic reaction and the associated pressure. With IsothermalTests at controlled and constant temperature are called isothermal.isothermal calorimetry, information for thermal management, obtained by means of Thermal runawayA thermal runaway is the situation where a chemical reactor is out of control with respect to temperature and/or pressure production caused by the chemical reaction itself. Simulation of a thermal runaway is usually carried out using a calorimeter device according to accelerated rate calorimetry (ARC).thermal runaway, can be directly obtained.

If you develop or produce raw materials for battery, design battery cells and packs you may want to:

Literature