Efficient Substance Identification Using Identify, …
It is possible to identify substances manually by comparing their characteristic data with literature sources or with previous measurements, but it is far more effective to automatize this process and to use databases for comparison purpose. Learn here how the NETZSCH software can do this for you!

Thermal Stability of Lithium Ion Battery Electrolyte
One of the components found in a lithium ion battery that is typically responsible for mishaps is the electrolyte. In the following article, several experiments were conducted via TGA, DSC and evolved gas analysis to investigate composition, thermal stability and identify the released products.

The Role of DSC in Lyophilisation Processes
Many APIs (active pharmaceutical ingredients) or formulations, especially those based on biopharmaceuticals, are thermally sensitive and unstable in aqueous solutions. In order to achieve higher stability and longer shelf life, such drug ingredients must be dried. Learn how thermal analysis can help determine the parameters of the freeze-drying process.

Call for Papers Now Open for ITCC 2021
Submit your abstract for the International Thermal Conductivity Conference (ITCC) 2021 in Boston! NETZSCH is inviting all partners, customers and scientists working in the field of thermal conductivity to send their abstracts dealing with new developments in theory, analysis, simulation and modelling, experimentation, demonstration, and case studies.

Watch Now! Free Rheology Webinars
If you missed out on any of our recent rheology webinars, the good news is that you can now watch them all for free!

Clear Raw Material Identification (RMID) Using DSC
Raw material identification or incoming goods inspection is of paramount importance for the quality and safety of drug products, wherever chemical substances are used in the pharmaceutical industry – maybe as an educt of chemical reactions or as a basis for further processing.

TGA-FT-IR – Your Solution to Identify a Polymer Blend and its Composition
Polymer blends offer significant advantages during their service life. However, they make recycling at the end of life difficult. One of the most fundamental problems is the identification of the material as a blend as well as its composition to ensure it is sorted properly and can be reused if possible. Read how to TGA and FT-IR help with the identification and join our webinar series on TG-FT-IR!

Investigating the Purity of Substances by Means of DSC
Differential Scanning Calorimetry (DSC) offers a quick and easy way to determine the purity of crystalline substances. Only one measurement with a few milligrams of sample is needed. Read here how it works!

The Importance of Purity Determination of Pharmaceuticals
The increasing number of product recalls in recent months has again made us aware how important the purity of drug ingredients is. Differential scanning calorimetry (DSC) is able to quickly analyze the absolute purity of chemical compounds within a single run, without the need for a reference standard.

Monitoring the Polymorphism of Paracetamol by Means of DSC
Paracetamol (acetaminophen) is the most commonly used medication for pain and fever in both the United States and Europe. However, it is not worth getting a headache when you think about its physicochemical properties. Thermal analysis, and especially differential scanning calorimetry (DSC), is of great help.