STA 509 Jupiter® Select with SKIMMER Coupling
The Unique Direct TG-DSC-MS Solution
Highlights
Unlock the Full Potential of High-Temperature Evolved Gas Analysis
The combination of the STA 509 Jupiter® Select and the SKIMMER coupling provides unmatched access to the gaseous products generated during thermal processes. While the STA reveals when thermal events occur, the integrated mass spectrometer identifies exactly which species are released, providing a comprehensive picture of material transformations.
At the heart of the system is the SKIMMER oupling interface. Its ultra-short, fully heated transfer path and supersonic molecular beam technology ensure maximum transfer efficiency while minimizing condensation and signal loss. The result is highly sensitive detection of gases, high-boiling compounds, salt vapors, and even metallic species at temperatures up to 1950 °C. For challenging materials and demanding thermal applications, the STA 509 Jupiter® Select with SKIMMER coupling offers a level of analytical performance unavailable with conventional gas transfer systems.

Why You Should Couple a Mass Spectrometer to a Thermal Analyzer
Coupling a mass spectrometer to a thermal analyzer significantly enhances material characterization by providing complementary information. While thermal analysis records changes in mass or heat flow, mass spectrometry detects and identifies the gases evolved during these processes — down to trace concentrations. Quadrupole mass spectrometers are particularly well suited for this purpose due to their high sensitivity, selectivity, and capability for continuous operation. This combination enables a deeper understanding of Decomposition reactionA decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. decomposition, OxidationOxidation can describe different processes in the context of thermal analysis.oxidation, and reaction mechanisms, making it ideal for both research and quality control.
Method

Double-Step Pressure Reduction
In this unique design, the first pressure-reduction step is located in the furnace, only a few millimeters above the sample. The second pressure-reduction step is located in the SKIMMER in the area of the compression zone formed behind the orifice.
In the SKIMMER furnace, an orifice system is used for the first pressure-reduction step for the ranges from 10-1 mbar to 10 mbar. As a second step, a SKIMMER is used as a molecular leak for the gas inlet into the high-vacuum recipient of the mass spectrometer.
Ideal Gas Flow Conditions Ensure Transport of All Relevant Gases
The aim of coupling is to have all relevant gases transported from the sample area into the ion source of the mass spectrometer for precise qualitative and quantitative analysis. This is only achieved through perfect gas flow conditions in the thermal analyzer, the coupling interface and the gas inlet of the mass spectrometer. As only a small quantity of gas is required for the analysis, a bypass is used at the gas outlet on the thermobalance for the excess purge gas flow; i.e., for the flow not passing through the coupling interface, which can be used for a second gas analyzer such as FT-IR.

Specifications

Advanced SKIMMER Coupling for High-Temperature Gas Analysis
- High transfer temperatures up to 1950 °C, depending on the furnace configuration, enable analysis of high-boiling compounds, salt vapors and even metal vapors.
- Shortest possible transfer path from the sample to the mass spectrometer for direct evolved gas analysis.
- Significantly reduced condensation risk thanks to the short, fully heated transfer interface.
- Seamless integration of STA and MS in the STA 509 Jupiter® Select with SKIMMER furnace for simultaneous thermal and evolved gas analysis.
Technical Data
Mass range: 1 u to 512 u
Mass filter: Quadrupole
Ion source: Electron impact ionization, adjustable up to 125 eV for soft and hard ionization modes
Detector: Faraday detector and SEM detector
Detection limit: < 100 ppb (gas-dependent, measured with toluene)
Vacuum: 5 × 10⁻⁶ mbar
Pressure reduction concept:
Two-stage pressure reduction using orifice and SKIMMER cone geometry
SKIMMER materials:
Polycrystalline alumina (up to 1450 °C) or glassy carbon (up to 1950 °C)
Transfer architecture:
Direct vertical coupling with fully heated gas transfer path and supersonic molecular beam technology
Measurement modes:
Analog Scan, Scan Bargraph, Multi Ion Detection (MID) with up to 64 selectable mass numbers and mass ranges

Brochures and Data Sheets:

Proven Excellence in Service
At NETZSCH Analyzing & Testing, we offer a comprehensive range of services globally to ensure the optimal performance and longevity of your thermoanalytical equipment. With a track record of proven excellence, our services are designed to maximize the effectiveness of your devices, extend their lifespan, and minimize downtime.
Unlock the full potential of your equipment with our tailored solutions, backed by years of industry expertise and innovation.
Software
The Software for Performing Simultaneous STA-MS Measurements with SKIMMER Coupling

Measurements using the STA 509 Jupiter® Select with SKIMMER coupling can be controlled entirely via NETZSCH Proteus® software, which integrates the measurement and analysis software of both coupled methods into a single application for control and data acquisition.
Proteus® allows individual definition of all parameters relevant to the STA (e.g., temperature program and heating rate) and the mass spectrometer (e.g., mass ranges and scans). For coupled measurements, the STA and MS are started and stopped simultaneously.
During measurement, the STA and MS data are displayed in a common plot and stored in one measurement file. This file is then used in the Proteus®® analysis software for joint presentation and evaluation, eliminating the need for complicated data import or switching between different applications.
Comprehensive Information via Scan-Bargraph
A scan-bargraph is often used as the basis for visualizing comprehensive information about all species evolved from a sample. Within the Proteus® software, users can display either all recorded mass numbers or only selected ones of interest, shown as time-resolved MID curves. In the example, one of the repeated scans is shown for heptadecane measured in argon.

Find out even more about the software:
- Complete integration of thermal analysis and QMS into Proteus®
- Method-based measurement and evaluation
- Simultaneous start/stop of coupled measurements
- Three scan modes: analog, bargraph, and MID
- Simultaneous use of different scan bargraph ranges
- Channel-specific optimization of scan mode, rate, and sensitivity
- Individual MS parameters per position of the automatic sample changer
- MS evaluation directly within Proteus®
- Precise correlation of MS data with time and temperature
- Display of MS signals (TIC and selected m/z) alongside thermal curves
- 3D visualization of spectra data combined with TGA/DSC and temperature
- Simple extraction of 2D MS data from 3D plots for database comparison
- Export of spectra in NIST format for external identification