07.02.2024 by Dr. Elena Moukhina, Aileen Sammler

Introducing Termica Neo: The New NETZSCH Software for Thermal Simulation in Industrial Settings

The new Termica Neo software enables users not only to analyze and simulate laboratory processes easily and precisely, but also to predict high-volume (kilograms and tons!) industrial processes to maintain the best product quality and safety.

For the simulation of temperature-dependent processes in the chemical industry, the temperature gradients in the reacting media could be significant and must be taken into consideration. For processes like curing or crystallization, the temperature gradient has an influence on product quality, and for highly EsotermicoUna transizione o reazione è esotermica se il materiale genera calore exothermal material it has an influence on the safety conditions of runaway reactions.

We are proud to present our new NETZSCH Termica Neo software, which uses all kinetic methods recommended by ICTAC*[1], is completely compatible with the NETZSCH-software Kinetics Neo, and works for both model-free and model-based approaches as well as for complex reactions with independent, competing, or consecutive steps.
 

*ICTAC: International Confederation of National or Regional Thermal Analysis and Calorimetry Societies. The aim of ICTAC is to promote international understanding and cooperation in thermal analysis and calorimetry through the organization of international congresses and the work of its scientific committees. (See also ictac.org)

[1] Vyazovkin S et al, ICTAC Kinetics Committee recommendations for analysis of multi-step kinetics, Thermochimica Acta, V.689, 2020, 178597

 
 

Simulation of High-Scale Industrial Processes to Avoid Runaway Actions and Explosion

Small samples with a weight of only a few milligrams measured by means of Differential Scanning Calorimetry (DSC) or with other thermal analytical methods like Thermogravimetric Analysis (TGA) or Accelerating Rate Calorimetry (ARC®) have no significant temperature gradient and are therefore suitable for kinetic analysis. The kinetic software can simulate the rate of chemical reactions for two limiting cases where samples have no temperature gradient. In the first case, the sample material has both infinite Conduttività TermicaThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity and infinite heat transfer to the surrounding, within a controlled surrounding. The second limiting case is pure AdiabaticoIl termine “Adiabatico” descrive un sistema o una modalità di misura che non comporta alcuno scambio di calore con l’esterno. Questa condizione può essere realizzata in strumenti come il calorimetro di reazione (ARC). Lo scopo principale di questo tipo di strumento è quello di studiare le reazioni termiche di fuga e quindi la situazione di caso peggiore (worst-case scenario). Una descrizione breve della condizione adiabatica è “non entra calore – non esce calore”. adiabatic heating without any heat loss.

However, in the chemical industry, as well as in the storage and transport of highly energetic materials, heat transport and heat loss are between these two limiting cases; and for safe conditions or to achieve desired product quality, we need to carry out the simulation for non-constant temperature in reacting volume.

The main applications of such a simulation in industry are product quality and safety.

In the polymer or ceramic industry, the areas with higher temperature have a higher reaction rate, which leads to differing physical properties of material at different coordinate points. This appears as shrinkage during SinteringSintering is a production process for forming a mechanically strong body out of a ceramic or metallic powder. sintering or curing, which produces mechanical StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress and has an influence on product quality.

In predictions regarding the storage or transportation of highly energetic material in the chemical industry, the temperature gradients in the reacting media are also significant and must be taken into consideration. For highly exothermal reactions, the areas with higher temperature and faster reactions have more intensive heat production and self-heating. Then such local areas become the hotspots for the beginning of runaway or thermal explosion. For reactions with lower thermal effect, the areas with higher temperature have a higher reaction rate and degree of conversion. This is the reason for the differing physical and chemical properties of materials at different coordinate points, which appear as heat capacity, heat conductivity or concentrations of reactants.

 
 

Simulation of Complex Chemical Processes with Termica Neo

Many existing FEM (Finite Element Method) software solutions can calculate the heat transfer, but they are limited in terms of complex multi-step chemical reactions with thermal effects present. Usually such systems work for model-free kinetics with a single kinetic equation, or for models with 1-2 steps in which all kinetic parameters are known.

The new Termica Neo software for thermal simulation consists of input data in the form of chemical parameters and equations directly from Kinetics Neo project. It is completely compatible with NETZSCH Kinetics Neo Software and is able to use both model-free and model-based approaches. For the model-based approach, there are no limitations on the number of individual reaction steps or on connections between them, including independent, competing, or consecutive ones.

The Termica Neo simulation software accepts all kinetic parameters from Kinetics Neo. It additionally uses temperature-dependent physical parameters like density, thermal conductivity, and the heat capacity of reacting materials and products from the materials library. The additional input parameters include containers for which the thickness and material can differ for each surface of reactor geometry and also include different surrounding media, for example, air on the top, water on the side and ground on the bottom. The surrounding temperature profiles can also be different for different geometry surfaces.

 

Figure 1: Temperature distribution for the vertical cross-section of an epoxy curing in cylindrical container with surrounding temperatures of 25°C (top), 100°C (side) and 120°C (bottom) after 130 minutes. Red areas show the hot spots due to self-heating.

What You can Do with Termica Neo 

Figure 2: Reactant in Adiabatic Container - Simulation of the temperature distribution of an adiabatic system: reactant (solid lines) in a container (dashed line).

The software provides time-dependent and coordinate-dependent results for temperature, concentrations of all reactants, and reaction rates in 2D and 3D view. A search for self-accelerating decomposition temperature (SADT) as well as a simulation of adiabatic conditions and infinite heat transfer to the surrounding are also available.

Features at a Glance:

 