Seminario

18.05.2023 15:3021:30

Dearborn, MI USA

How to Optimize Your Polymer Workflow with Thermal Analysis and Rheology

Registration is closed, we're at capacity.

Attendees will be introduced to the basic techniques of thermal analysis and rheology, including but not limited to DSC, TGA, STA, LFA, rotational and capillary techniques.  An overview of the theory will be given, followed by instrumentation basics as well as how instrument configuration can impact results. Finally, real world application examples will be discussed for each characterization technique. There will be ample time for attendees to discuss their applications with our experts.

  • Detailed Schedule is below


Registration is closed, we're at capacity. Please email us for questions:

Location

Doubletree Hotel
Dearborn, MI
5801 Southfield Fwy
Detroit, MI 48228
Phone: (313) 336-3340

Date and time

18  May 2023
9 AM - 3:30PM

Registration

Registration is closed, we're at capacity.

AGENDA

 

How to Optimize Your Polymer Workflow with

Thermal Analysis and Rheology 

 

 
 

 Thursday, May 18 , 2023

 
8:45 am - 9:15 am Arrival and Continental Breakfast  
9:15 am - 9:30 am Welcome and Introduction to NETZSCHDr. Natalie Rudolph, Peter Vichos
9:30 am - 10:30 am Quality Control and Failure Analysis by DSC (Differential Scanning Calorimetry) 
10:30 am -10:45 am ***BREAK*** 
10:45 am -12:00 am Plastics in the Flow by Rotational and Capillary RheologyDr. Natalie Rudolph
12:00 am-12:30 pm Compositional Analysis of Compounds by TGA (Thermogravimetric Analysis) - An Overview 
12:30 pm -1:45 pm ***LUNCH*** 
1:45 pm - 2:15 pm Characterization of the Viscos-elastic Properties of Polymers by DMA (Dynamic Mechanical Analysis)Dr. Natalie Rudolph
 2:15 pm - 3:00 pmCure Monitoring of Thermosetting Resins by DEA (Dielectric Analysis)Dr. Natalie Rudolph
   3:00 pm  Wrap-up and DiscussionPeter Vichos 
 

* Participants receive a USB drive containing all Presentation Material and Product Literature

 
Dr.-Ing. Natalie Rudolph

„Whether you are a complete beginner, or an expert planning to bring your most challenging application questions, we look forward to seeing you there“

Dr.-Ing. Natalie Rudolph
Business Field Manager Polymer