NETZSCH Heat Flow Meters for measuring thermal conductivity in insulation materials, showcasing three different models.

Learn, Apply, Achieve.

HFM E-Learning Courses

Become an expert in Heat Flow Meter Technology

The HFM method is one of the most commonly used methods in the field of thermal insulation materials. With this method you can determine Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity values of, e.g., building materials like wood or concrete, thermal insulation for buildings like mineral wool or foamed polystyrene or even vacuum insulation panels.

Start your learning journey today and turn complex techniques into practical expertise

All NETZSCH E-Learning Basic Courses are Free of Charge! The content is created by our laboratory method experts, who share their personal experiences with you.

Our courses will guide you step by step — from theory and measurement setup to sample preparation and software handling. Learn how to identify influential factors, understand thermal effects and evaluate your results with confidence.

Our E-Learning videos provide practical demonstrations to help you master thermal analysis methods, rheology and fire testing for colleges/universities, research, industry and quality control.

Please accept Marketing Cookies to see that Video.

Discover all E-Learning Courses

Check out our range of E-Learning Courses for different devices and software. Learn new measurement techniques and theories in Thermal Analysis, Rheology, and Fire Testing.  See how you can easily become an expert in your lab with extensive expertise.

Explore the range of NETZSCH HFM and GHFM instruments 

A middle-aged man and a young woman collaborate at a table, analyzing data on a tablet in a modern office setting.

Consultancy & Sales

Do you have further questions about the instrument or the method? Would you like to speak to a sales represenative?

Service & Support

Do you already have a NETZSCH instrument and need technical support or spare parts?

Smiling customer support representative in a modern office, engaged in a conversation while working on a computer.
Two lab technicians analyze thermal analysis data on a computer screen, showcasing NETZSCH software in a laboratory setting.

Academy & Training

Would you like us to provide online live training or on-site training at the laboratory to meet your specific requirements?

AI Overview
An error occurred. Please try again.