Fire Testing Systems for Cables
Fire Safety Starts at the Core – Reliable Cable Testing Solutions by NETZSCH
NETZSCH fire testing solutions support key international standards such as EN 50399, IEC 60332-3-10, EN 60695 or ISO 4589‑2 to assess for example flame spread, heat release, flaming droplets and ignition resistance of cable insulation and sheathing materials. These tests are essential for manufacturers, testing laboratories and certification bodies to ensure compliance and product safety.
We can also provide further variants and individual fire testing instruments according to customer requirements.
Our Product Portfolio
Explore the range of NETZSCH Fire Testing Instruments for Cables

The Master of Fire
"We couldn’t fathom working without the two NETZSCH fire testing systems KBT and SBI. Since 2005, they have served for reliable tests on the behavior of building components like cables and insulated lines in the event of fire in accordance with the European test procedures."
Materialprüfanstalt Dresden (MPA, Dresden Materials Testing Institute), Germany
Frequently Asked Questions
Of course! TAURUS Instruments GmbH became part of NETZSCH Analyzing & Testing in 2020.
As of July 1, 2025, NETZSCH Taurus Instruments GmbH change its name to NETZSCH-Gerätebau GmbH. Both entities now operate under the name NETZSCH-Gerätebau GmbH.
As part of the NETZSCH Analyzing & Testing business unit, the company combines decades of fire testing expertise with NETZSCH’s global resources, innovation, and service network — offering customers a comprehensive portfolio of fire testing and Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity systems for building materials, cables, automotive components, and more.
Want to learn more about the history of our fire testing devices? Read the following blog articles:
EN 13501 is the European standard for fire-classifying construction products and building elements.
As part of the EU’s harmonized approach to fire safety, it is used across all EU member states (and many associated countries) to determine how materials and building components behave in a fire. Materials are categorized into different classes (A1 to F) based on their reaction to fire, smoke production, and flaming droplet production. This classification system helps determine the suitability of materials for various building applications. EN 13501 is divided into several parts, each covering a different type of fire performance classification:
EN 13501-1: Reaction to Fire
This part classifies how construction products (including floorings) contribute to the development of a fire.
Common classes: A1, A2, B, C, D, E, and F (A1 is non-combustible and F indicates that no performance has been determined). It also includes smoke production (s1, s2, s3) and flaming droplets/particles (d0, d1, d2).
EN 13501-2: Fire Resistance
This part classifies the fire resistance of building elements (e.g., walls, doors, floors, and beams) based on how long they maintain their integrity, insulation properties, and/or load-bearing capacity.
EN 13501-3: This part classifies the fire resistance of service installations (e.g., ducts and fire dampers).
EN 13501-4: This part classifies the fire resistance of smoke control systems.
Why It Matters:
Under the EU Construction Products Regulation (CPR), many construction products must bear a CE marking. This requires verified fire performance data according to EN 13501, which ensures that fire safety classifications are comparable and reliable across all European countries.
Meeting these fire classification requirements is critical in order for architects, builders, and material suppliers to ensure that their materials comply with building codes and can be legally placed on the market.
NETZSCH supports manufacturers and testing laboratories in achieving these certifications with its advanced fire testing instruments. Our devices, including cone calorimeters, SBI (single burning item) testers, and KBT (klein-brenner-test) systems, provide precise, standards-compliant measurements of reaction-to-fire and fire-resistance properties. These instruments enable our customers to generate accurate, repeatable data fully aligned with EN 13501 classification needs. This helps them bring safe, compliant products to market with confidence.
Explore the key fire testing methods for cable materials used in buildings and infrastructure. Whether assessing flame behavior, dripping particles, or ignition resistance, these standardized tests provide essential data for product development, quality assurance, and regulatory compliance.
The table below highlights the main focus, standard and application of each method.
| Instrument / Method | Test Scope | Standards, e.g. | Typical Applications |
|---|---|---|---|
| UL94 | Vertical and horizontal flame spread; dripping particles and afterflame time | UL 94, EN 60695, ISO 9772 etc. | Plastic cable sheaths, connectors, housing materials, printed circuit board |
| LOI 901 | Minimum oxygen concentration to sustain combustion | ISO 4589‑2, ASTM D2863 | Cable insulation, polymer compounds, flame-retardant material screening |
| KBT 916 | Flame spread, heat release, smoke production, and burning droplets in vertical cable trays | EN 50399 and IEC 60332-3-10 | Bunched cables for buildings and infrastructure (CPR classification) |
Still not sure which instrument fits your application? Or do you need an individualized configuration?
No problem. Please contact your regional sales respresentative. We will be happy to find the best solution for your fire testing needs together:
UL 94 is one of the most widely recognized flammability standards for plastics. It defines methods to classify materials based on how they burn in different orientations and under different conditions.
NETZSCH offers dedicated UL94 flammability test instruments designed to perform the full range of UL 94 classifications under controlled and repeatable conditions:
- ASTM Standards
- ASTM D635, D3801, D4804, D5048, D4986,
- ASTM D5025, D5207
- European Standards
- EN 60695 Part 11-10, EN 60695 Part 11-20, EN 60695 Part 11-3, EN 60695 Part 11-4, IEC EN 60707
- EN 60695 Part 11-10, EN 60695 Part 11-20, EN 60695 Part 11-3, EN 60695 Part 11-4, IEC EN 60707
- ISO Global Standards
- ISO 1210, ISO 9772, ISO 9773, ISO 10093, ISO 10315
The cost of a NETZSCH fire testing device can vary significantly depending on the type, model, features, or any additional accessories you may require.
To get an accurate and up-to-date price for your individual NETZSCH instrument, please contact your local NETZSCH representative or one of our authorized distributors. We will provide a quote tailored to your specific requirements, including any necessary training, installation, or additional features.
Delivery times depend on the specific device and configuration. While some instruments may be available from stock, others require longer lead times. For customized systems, delivery schedules can vary accordingly.
For the most up-to-date information, we encourage you to contact us directly with a specific request. This will ensure that we can provide you with an accurate timeline tailored to your specific needs.
Your Benefits
> 30
> 1000
50
What Makes NETZSCH Fire Testing Instruments Unique?
- Standards compliance designed for UL 94, ISO 4589‑2 (LOI) and EN 50399 (KBT) — allowing for accurate and compliant results
- High repeatability and precision through automated ignition control, digital data acquisition and stable testing equipment
- Reliable analysis of key parameters such as flame spread, oxygen index, heat release rate, smoke production and dripping particles
- Intuitive operation via user-friendly software and touch-panel interfaces
- Ideal for quality control, research, development and certification in the cable and electrical industries
- Proven Excellence: Decades of experience in fire testing and a strong reputation on the market underline the reliability and advanced capabilities of our fire testing instruments.
- Unlimited Warranty: To emphasize the long-term availability of our services, we offer an unlimited warranty, e.g. for the KBT 916 instrument series.
Applications for the Cable Industry
NETZSCH fire testing instruments are used by cable manufacturers, testing laboratories, and certification bodies to assess the fire behavior of cable components. Key applications include:
- Flame propagation testing:
Evaluate how flames spread along vertically mounted cable bundles — crucial for classifying cables under the Construction Products Regulation (CPR) using EN 50399. - Heat release and smoke production analysis:
Quantify heat release rate (HRR), total heat release (THR), smoke production rate (SPR), total smoke production (TSP), FIGRA, SMOGRA and smoke development to assess fire load and visibility risks during a fire. - Dripping particles and afterflame time:
Identify whether burning droplets form and how long materials continue to burn after ignition (tested via UL 94 and KBT) — important for preventing secondary ignition. - Oxygen index determination:
Measure the minimum oxygen concentration required to support combustion (LOI test according to ISO 4589‑2) — a key screening method for flame-retardant cable compounds. - Material screening and compound development:
Support R&D by comparing flame-retardant formulations, fillers and additives for improved fire safety. - Certification and regulatory compliance:
Ensure that cable products meet international fire safety requirements for installation in buildings, tunnels, industrial plants and public infrastructure.

Cables and lines - Invisible lifelines of our modern world
They power our homes, connect our devices and keep critical infrastructure running — all while working quietly and reliably in the background.
To ensure the highest level of safety and fire protection, it is crucial to understand how cable materials behave in a fire. Only through precise testing and reliable data can manufacturers design cables that perform well and protect lives, property and the systems we depend on daily.
Are you interested in fire testing devices for other industries or applications?
Feel free to take a look at our entire range of fire testing systems.
Media and Training
Blog articles about NETZSCH fire testing devices
- 23.10.2025
NEW: The NETZSCH UL 94 Classic – the Base Version for Reliable Flammability Testing

- 13.05.2025
Peace of Mind with NETZSCH: Introducing the Unlimited Warranty

- 05.03.2025
Fire Testing of Stabilized Polyacrylonitrile (PAN) Fibers with the NETZSCH LOI 901

- 17.04.2023
How to Determine the Burning Behavior of Plastics according to ISO 4589-2 and ASTM D2863

- 29.03.2023
Five Advantages of the NETZSCH KBT 916 Cable Tester

- 22.12.2022
Advent, Advent – The Toy´s on Fire!

- 23.11.2022
60 Years of NETZSCH-Gerätebau: Master of Fire

- 23.04.2020
A new milestone in fire testing of cables compliant to EN 50399

Videos that may be interesting for you

FAQs about NETZSCH Service
We want you to be fully prepared when using your fire testing device!
At NETZSCH, we want to ensure that you are well-prepared when working with your fire testing instrument. That’s why we offer customized training designed around your specific equipment and operating conditions.
We prefer on-site training at your location, working directly with your instrument under your specific conditions (e.g., gas setup, pressure ranges, and gas cylinders). This ensures that everything works seamlessly and that optimal test conditions are achieved.
Of course, we also offer online training via our NETZSCH Online Academy NOA, 1:1 remote training and on-site training at your location or our training centers. Simply contact your sales representative or go to Know-How - NETZSCH Analyzing & Testing
Yes, we offer maintenance contracts for your instruments according to the different regional and individual customer requirements. Please feel free to contact our Service Department or take a closer look at our website section Service-Level Agreement - NETZSCH Analyzing & Testing.
For even greater peace of mind, we also offer Unlimited Warranty for our SBI 915 and KBT 916 fire testing instruments.
Our NETZSCH Applications Laboratory exclusively offers contract testing services for the TCC 918 Cone Calorimeter, supporting a wide range of industries and research centers. With our state-of-the-art instrumentation, we can perform detailed fire behavior analyses without requiring in-house equipment.
Although we only perform contract testing on the TCC 918, our sales and service teams are always available to assist with other fire testing inquiries, including application advice and selecting the right instrument for your needs.
Consult our NETZSCH experts to determine the best measuring method for your application. You will work with experienced scientists, including physicists, chemists, and materials specialists, who have in-depth knowledge of various test methods and material types.
We offer:
- Installation and commissioning
- Relocation of your instrument
- System upgrades
- Maintenance and inspection
- Calibration
- Repair
- Free e-learning basic courses: E-Learning - NETZSCH Analyzing & Testing
- Comprehensive training from basic to advanced use of the instrument - on-site and online.
Our Remote Service is available worldwide.















