Advanced solvent extraction apparatus with digital display, glass tubes, and orange tubing, designed for precise testing.
Fire Testing

LOI 901

Oxygen Index Analyzer

Highlights

Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2 and ASTM D 2863 

Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate the device. All relevant data such as temperature, flow rate and time are displayed during the test.
Except for the test gases (O2 / N2), all necessary accessories for performing standard tests are included with the device and greatly simplify day-to-day work at the lab.

  • Sample holders available for rod-shaped and flat samples
  • Easily replaceable borosilicate glass column
  • Propane igniter
  • Fully automatic calibration
  • Automated testing procedure
  • User guidance via high-resolution 7“ touch display with brilliant colors and intuitive menu icons
  • All necessary accessories for standard tests included with the device (options see separate technical datasheet)
  • Single board computer with Windows operating system
  • Single license for the LOI software
Assorted blue plastic and glass bottles, featuring water and liquid soap dispensers, showcasing eco-friendly packaging options.

Specifications

Measurement method

Determination of the burning behavior of plastics by oxygen index at ambient

temperature in accordance with ISO 4589-2 and ASTM D 2863

Sample holder
  • 1x for rod-shaped specimens 
  • 1x for flat specimens 
  • 1x for round, rod-shaped specimens
Ignition device

Propane gas igniter with handle, fine adjustment and shut-off valve

according to standard (Gas to be provided by the user)

A red racing car is in the pit, surrounded by a team in red uniforms, preparing for a quick tire change during a race.

Consultancy & Sales

Do you have further questions about the instrument or the method and would like to speak to a sales representative?

Service & Support

Do you already have an instrument and need technical support or spare parts?

Customer support representative at a computer, smiling and engaged, highlighting NETZSCH's commitment to service excellence.


Proven Excellence in Service

At NETZSCH Analyzing & Testing, we offer a comprehensive range of services globally to ensure the optimal performance and longevity of your thermoanalytical equipment. With a track record of proven excellence, our services are designed to maximize the effectiveness of your devices, extend their lifespan, and minimize downtime. 

Unlock the full potential of your equipment with our tailored solutions, backed by years of industry expertise and innovation.

Downloads and Media

AI Overview
An error occurred. Please try again.