LOI 901
Oxygen Index Analyzer
Highlights
Testing system for determining the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2 and ASTM D 2863
Compact and lightweight, the device features a high-resolution touch display for intuitive user guidance. The fully automatic calibration and testing functions make it easy to operate the device. All relevant data such as temperature, flow rate and time are displayed during the test.
Except for the test gases (O2 / N2), all necessary accessories for performing standard tests are included with the device and greatly simplify day-to-day work at the lab.
- Sample holders available for rod-shaped and flat samples
- Easily replaceable borosilicate glass column
- Propane igniter
- Fully automatic calibration
- Automated testing procedure
- User guidance via high-resolution 7“ touch display with brilliant colors and intuitive menu icons
- All necessary accessories for standard tests included with the device (options see separate technical datasheet)
- Single board computer with Windows operating system
- Single license for the LOI software

Specifications
| Measurement method | Determination of the burning behavior of plastics by oxygen index at ambient temperature in accordance with ISO 4589-2 and ASTM D 2863 |
|---|---|
| Sample holder |
|
| Ignition device | Propane gas igniter with handle, fine adjustment and shut-off valve according to standard (Gas to be provided by the user) |

Related Devices

Proven Excellence in Service
At NETZSCH Analyzing & Testing, we offer a comprehensive range of services globally to ensure the optimal performance and longevity of your thermoanalytical equipment. With a track record of proven excellence, our services are designed to maximize the effectiveness of your devices, extend their lifespan, and minimize downtime.
Unlock the full potential of your equipment with our tailored solutions, backed by years of industry expertise and innovation.
Downloads and Media
Brochure and Datasheet
Application Literature
Our latest blog articles
- 21.04.2026
More Transparency in Combustion Gas Analysis: OMEGA 5 FT-IR Coupling on the NETZSCH TCC 918 Cone Calorimeter

- 23.10.2025
NEW: The NETZSCH UL 94 Classic – the Base Version for Reliable Flammability Testing

- 23.09.2025
How Material Thickness Influences Fire Testing – Key Insights by Means of Cone Calorimeter Analysis

- 19.08.2025
EN 13501 – Fire Classification in Europe and How NETZSCH Supports Compliance

- 05.03.2025
Fire Testing of Stabilized Polyacrylonitrile (PAN) Fibers with the NETZSCH LOI 901

- 12.08.2024
Fire Resistance Testing and Fire Safety Engineering