NETZSCH DSC 214 Nevio, a differential scanning calorimeter, features a user-friendly interface for precise thermal analysis.
Differential scanning calorimetry

DSC 214 Nevio

Studying Phase Transformations of Pharmaceuticals, Foods and Cosmetics

…by means of the DSC 214 Nevio ‒ the fastest heat-flux DSC instrument on the market.

Information obtained by differential scanning calorimetry (DSC):

Features of the DSC 214 Nevio:

Intelligent software – AutoEvaluation and Identify

AutoEvaluation, a unique feature of the Proteus® software, evaluates EndothermicA sample transition or a reaction is endothermic if heat is needed for the conversion.endothermic or ExothermicA sample transition or a reaction is exothermic if heat is generated.exothermic effects fully automatically with just one click. The result of this evaluation can serve as a second opinion when assessing samples of unknown composition.Identify is a database system for curve recognition and interpretation. The included libraries currently contain more than 1200 entries. However, customers can easily create their own libraries and expand them with own measurements.


Compactness

With its space-saving design, the DSC 214 Nevio fits into even the smallest of labs.


Everything in one package

Even the basic version of the instrument comes with everything necessary to perform measurements correctly and evaluate them successfully.


Ready if you need it

Using the SetPoint function, it is possible to schedule the day and time when the cooling device and the gas flow should be active, so the DSC is always ready for work right on time.


Perfectly synchronized sensor/crucible system

A Concavus® pan, which features a concave outer bottom, forms a clearly defined, ring-shaped contact zone when positioned on the sensor. This results in optimum reproducibility.


The automatic sample changer (ASC) works overnight or during the weekend

Up to 19 samples – either belonging to a single series or independent of each other – can be handled with the optional automatic sample changer without operator intervention. This frees up time to focus on other important tasks.

The Proteus®Protect software meets the requirements of 21 CFR Part 11.

Request a Quote

Get a personalized offer now.

Request a Quote

Technical Data

Temperature range (max.)
-170°C to 600°C
Measuring range
± 750 mW
Max. cooling rate/max. heating rate
500 K/min
NETZSCH DSC 214 Nevio, a differential scanning calorimeter for thermal analysis, featuring a user-friendly control panel.

Enthalpy accuracy:
< 1%**

TGA resolution:
n/a

Indium Response Ratio (*):
> 100

Exchangeable sensors:
n/a

Cooling options:
Air compressor: RT to 600°C
Compressed air: < 0°C to 600°C
Intracooler: -70°C to 600°C
Liquid nitrogen: -170°C to 700°C

Gas atmospheres:
Inert, oxidizing, static and dynamic

Mass flow controller for purge/protective gas:
3, integrated (0 to 250 ml/min)

Gas flow regulation:
Software-controlled

Automatic Sample Changer (ASC):
Yes (optional)

* minus weight of crucible
** for indium

Software:
min. Proteus® 8

Proteus® software extensions included:SmartModeExpertModeAutoCalibration(Advanced) BeFlat®
AutoEvaluationIdentify

Proteus® software extensions (optional):
Temperature modulation
Specific Heat Capacity (cp)Heat capacity is a material-specific physical quantity, determined by the amount of heat supplied to specimen, divided by the resulting temperature increase. The specific heat capacity is related to a unit mass of the specimen.Specific heat capacity (Specific Heat Capacity (cp)Heat capacity is a material-specific physical quantity, determined by the amount of heat supplied to specimen, divided by the resulting temperature increase. The specific heat capacity is related to a unit mass of the specimen.cp)Proteus® ProtectPurity Determination

Advanced Software extensions (optional):Peak SeparationKinetics NeoThermal Simulations

Size (W x H x D) – incl. ASC, without physical connections:
350 mm x 445 mm x 560 mm

DSC 214 Nevio from NETZSCH, a differential scanning calorimeter for thermal analysis, featuring a user-friendly interface.
Laboratory professionals in white coats working with advanced analytical equipment, featuring the LabV® logo prominently.

This instrument is LabV®®️-primed

LabV®®️ takes the data from your analytical instrument: It automatically imports all measurement data into a central and secure database solution, the LabV®®️ software. This allows you to visualize the data in LabV®®️ and to make them searchable. Your data will now be accessible from anywhere. Moreover you have the possibility to generate reports.

Product Information

We do not only promise quality, but also individual consulting. Let us start your project together.

Request Information
AI Overview
An error occurred. Please try again.