Seminar

04.11.2026

Budapest

Characterization of materials using advanced thermal analysis and fire testing techniques

We warmly invite you to take part in a seminar entitled ‘Characterization of materials using advanced thermal analysis and fire testing techniques’, organised by NETZSCH and Austro-Lab.

The aim of the seminar is to familiarize participants with thermal analysis and fire testing methods used in many fields of science and industry. The presentations will be delivered by specialists from NETZSCH, as well as users who apply thermal analysis methods on a daily basis.  The topics will cover both the theoretical foundations and the practical applications of thermal analysis and fire testing methods in laboratory and industrial research. The seminar will be accompanied by an exhibition and live demos of thermal analysis and fire testing equipment.

Program

8:00 - 9:00Doors Open & Registration 
9:00 - 9:20Welcome & Introduction to NETZSCH and Austro-LabDr. Krzysztof Hodor, NETZSCH Analyzing & Testing
Zselyke Erhart-Szakács, Austro-Lab
9:20 - 10:00Introduction to NETZSCH Thermal Analysis Portfolio Dr. Krzysztof Hodor, NETZSCH Analyzing & Testing
10:00 - 10:20Introduction to NETZSCH Rheology PortfolioTorsten Remmler, NETZSCH Analyzing & Testing
10:20 - 10:50Coffee Break 
10:50 - 11:10NETZSCH DSC lineBoldizsár Árpád Rácz, Austro-Lab
11:10 - 11:40Advanced NETZSCH Proteus® Software – live demo DSC 300 Caliris® Classic Dr. Hilary Smogor, NETZSCH Analyzing & Testing
11:40 - 12:00Invited lecture I:  Material Characterization by Thermomechanical and Dynamic Mechanical Analysis at BoschDr. Erzsébet Sára Bogya Ambrus, Robert Bosch kft.
12:00 - 12:20Invited lecture II -  Application of Thermal Analysis in the Investigation of Clay MineralsDr. Tibor Németh, University of Pécs, Faculty of Sciences and Eötvös Loránd University, Faculty of Science 
12:20 - 12:40Invited lecture III -  Identification, QC and R&D applications of polymer compositesDr. Katalin Litauszki, Budapest Technical University and Economics, Department of Polymer Engineering
12:40 - 13:40Lunch Break 
13:40 - 14:40Introduction to NETZSCH Fire Testing PortfolioStephan Strickmann, NETZSCH Analyzing & Testing
14:40 - 15:00Invited lecture IV - In the Footsteps of Fire - Measurements with the Cone Calorimeter, or Burning Problems and Their SolutionsDr. Beáta Szolnoki, Budapest Technical University and Economics, Faculty of Chemical Technology and Biotechnology
15:00 - 16:00Fire testing techniques - Live Demos 
16:00 - 16:15Final Remarks and Goodbye 

Date and Location

Wednesday, November 4

Danubius Hotel Helia
1133 Budapest, Kárpát utca 62–64

AI Overview
An error occurred. Please try again.