Webinar
14.01.2027
Fiber Reinforced Polymer Characterization: From Cure Monitoring to Composite Performance
English
Speaker: Dr. Andreas Spörrer

Fiber reinforced composites require precise control of Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing behavior during processing, to obtain expected mechanical and thermal material properties. This webinar provides a practical overview of analytical methods that support composite development, production monitoring, quality assurance, and failure analysis.
Learn how DSC and DEA can evaluate Phase TransitionsThe term phase transition (or phase change) is most commonly used to describe transitions between the solid, liquid and gaseous states.phase transitions and Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing behavior; how TGA can determine material composition and Thermal StabilityA material is thermally stable if it does not decompose under the influence of temperature. One way to determine the thermal stability of a substance is to use a TGA (thermogravimetric analyzer). thermal stability; and how TMA, DMA, and LFA provide insight into thermal expansion, viscoelastic properties, stiffness, damping, and Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity. We will also address anisotropic effects, which are especially relevant for fiber-reinforced composites.
Join this webinar to understand how characterization can support more reliable composite performance.
