General Properties
Short Name: PA12
Name: Polyamide 12
Of all polyamides, polyamide 12 absorbs the least amount of water. The higher the ration of -CH2 groups to -CONH- groups, the lower the water absorption and the better the dimensional accuracy. PA12 features a lower stability and hardness than PA6 und PA6.6.
Structural Formula

Properties
NETZSCH Measurement

| Sample Mass | 11.55 mg |
| Heating Rates | 10 K/min |
| Crucible | Al, pierced lid |
| Atmosphere | N2 (50 ml/min) |
Evaluation
In this measurement, evaporation of water occurred at 94°C (peak temperature 1st heating, blue). The shift in the position of the Glass Transition TemperatureThe glass transition is one of the most important properties of amorphous and semi-crystalline materials, e.g., inorganic glasses, amorphous metals, polymers, pharmaceuticals and food ingredients, etc., and describes the temperature region where the mechanical properties of the materials change from hard and brittle to more soft, deformable or rubbery.glass transition in the 2nd heating (red, Tg of 43°C – midpoint with a Δcp value of 0.11 J/(g·K)) after water evaporation was smaller than that on page 95. The cooling rate selected in the experiment (in this case 10 K/min) was lower than the cooling rates polymer granulates generally experience during production. Therefore, the amorphous content of the sample was lower in the 2nd heating. This thesis is confirmed by the relatively high step height (Δcp) of the Glass Transition TemperatureThe glass transition is one of the most important properties of amorphous and semi-crystalline materials, e.g., inorganic glasses, amorphous metals, polymers, pharmaceuticals and food ingredients, etc., and describes the temperature region where the mechanical properties of the materials change from hard and brittle to more soft, deformable or rubbery.glass transition in the 1st heating (blue) as well as the ExothermicA sample transition or a reaction is exothermic if heat is generated.exothermalPost Crystallization (Cold Crystallization)The post crystallization of semi-crystalline plastics occurs primarily at elevated temperatures and increased molecular mobility above the glass transition.post-crystallization (peak temperature: 159°C, CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released.crystallization enthalpy: 2.2 J/g) that occurred immediately prior to melting.
The endothermal melting effect at 178°C (peak temperature, 2nd heating) exhibited a melting enthalpy of approx. 34 J/g.