Basic Course
HFM 706 Lambda Small

Language: English - Duration: 67 Min.

Syllabus

Explore the range of NETZSCH HFM and GHFM instruments

  • HFM 706 Lambda Small
    HFM 706 Lambda Small

    An exact, fast and easy-to-use instrument for measuring the low thermal conductivity, λ, of insulation materials.

    • Thermal conductivity range: 0.007 to 2 W/(m·K)
    • Metering area heat flux transducer: 102 mm x 102 mm
    • Specimen sizes (max.): 203 mm x 203 mm x 51 mm
  • HFM 706 Lambda Medium
    HFM 706 Lambda Medium

    An exact, fast and easy-to-use instrument for measuring the low thermal conductivity, λ, of insulation materials.

    • Thermal conductivity range: 0.002 to 2 W/(m·K)
    • Metering area heat flux transducer: 102 mm x 102 mm
    • Specimen sizes (max.): 305 mm x 305 mm x 105 mm
  • HFM 706 Lambda Large
    HFM 706 Lambda Large

    An exact, fast and easy-to-use instrument for measuring the low thermal conductivity, λ, of insulation materials.

    • Thermal conductivity range: 0.001 to 0.5 W/(m·K)
    • Metering area heat flux transducer: 254 mm x 254 mm
    • Specimen sizes (max.): 611 mm x 611 mm x 200 mm
  • HFM 446 Lambda Small Eco-Line
    HFM 446 Lambda Small Eco-Line

    An exact, fast and easy-to-use instrument for measuring the low thermal conductivity, λ, of insulation materials.

    • Thermal conductivity range: 0.007 to 2 W/(m·K)
    • Metering area heat flux transducer: 102 mm x 102 mm
    • Specimen sizes (max.): 203 mm x 203 mm x 51 mm
  • TCT 716 Lambda
    TCT 716 Lambda

    Determine the thermal conductivity of round solid specimens in the low- and medium-conductivity range with our Guarded Heat Flow Meter:

    • Sample mean temperature range: -10°C to 300°C
    • Thermal conductivity range: 0.1 … approx. 30 W/(m·K)
    • Two independent test stacks to measure two samples at the same time

A middle-aged man and a young woman collaborate at a table, analyzing data on a tablet in a modern office setting.

Consultancy & Sales

Do you have further questions about the instrument or the method? Would you like to speak to a sales represenative?

Service & Support

Do you already have a NETZSCH instrument and need technical support or spare parts?

Smiling customer support representative in a modern office, engaged in a conversation while working on a computer.
Two lab technicians analyze thermal analysis data on a computer screen, showcasing NETZSCH software in a laboratory setting.

Academy & Training

Would you like us to provide online live training or on-site training at the laboratory to meet your specific requirements?

AI Overview
An error occurred. Please try again.