Glossary

Delamination (Time to Delamination)

Delamination refers to the separation of layers from one another – e.g., of a resin from a laminate or of fibers from a resin. Such processes cause defects in printed circuit boards. 

ICP-TM-650 No. 2.4.24.1 describes the method of determining the time to delamination for laminates and printed boards through the use of a thermomechanical analyzer (TMA).

The sample is heated to a specified IsothermalTests at controlled and constant temperature are called isothermal.isothermal temperature at 10 K/min and is then held at this temperature for 10 minutes or until failure (see figure 1).

Scan graph depicting epoxy material behavior at 260°C showing dimensional thickness and temperature changes over time.
Figure 1: Typical scan of an epoxy material at 260°C (taken from ICP-TM-650 No. 2.4.24.1)

Do you have any questions?

Our experts will be happy to help you.

Contact us

Suitable products for your measurement

AI Overview
An error occurred. Please try again.