Clear blue water droplets with intricate textures and reflections, creating a serene atmosphere ideal for soft materials testing.

Open-Source Rheology Solutions by NETZSCH

Transform Soft Material Testing with Rheodialysis for NETZSCH Kinexus Rheometer

Rheodialysis technology: A new tool for real-time characterization and testing of soft materials.

Rheodialysis allows for real time changes of a sample´s chemistry by applying ions via a membrane into the sample on a rotational rheometer.

Explore the innovative rheodialysis developed by the University of Liverpool(Dr. Anders Aufderhorst-Roberts, Lecturer in Sustainable & Biological Materials at the School of Engineering) and Durham University(Prof. John Girkin, Professor of Biophysics at the Department of Physics) in collaboration with NETZSCH, offering an unprecedented capability to probe the interplay between chemical environments and mechanical forces in soft materials.

More often than not, when a material encounters a change in shear environment, this coincides directly with change in chemical environment. But commercial rheometers cannot control shear and chemistry simultaneously and this represents an obvious blindspot when understanding the processing of soft structured materials and their end use applications. It’s also integral to many biological processes.
Rheodialysis is a new device that represents our shared vision to address this blindspot. It’s a joint endeavour between my team, our collaborators at Durham University and our colleagues at NETZSCH. Rather than commercialising this device, we’re making it fully and freely available to all interested users. If you believe this might help you answer new research questions, we’d like to hear from you. Please get in touch below.

Dr. Anders Aufderhorst-Roberts
Dr. Anders Aufderhorst-Roberts
Lecturer in Sustainable & Biological Materials at the Faculty of Science and Engineering at the University of Liverpool

WHY RHEODIALYSIS?

Soft materials rarely experience mechanical forces in isolation.

In real processes, shear and chemistry change at the same time.

Until now, commercial rotational rheometers could control mechanical StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress and StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.strain – but not the chemical environment dynamically during the test. This created a blind spot in understanding gels, biopolymers, pharmaceuticals, food systems and biological materials.

With the new Rheodialysis solution for the NETZSCH Kinexus rotational rheometer, this gap has been closed.

Consider an alginate hydrogel used to encapsulate an active pharmaceutical ingredient.

As soon as the material comes into contact with calcium ions, it begins to transform from a liquid into a gel. At the same time, diffusion processes occur, the structure changes, and its mechanical properties evolve continuously.

Until now, researchers could typically monitor either the chemical changes or the rheological response. Studying both simultaneously under realistic conditions remained extremely challenging.

Rheodialysis changes this. It enables researchers to observe how a material responds mechanically while its chemical environment evolves in real time – bringing laboratory measurements much closer to real-world conditions.

The term combines two concepts:

  • Rheology – the study of how materials flow and deform
  • Dialysis – the controlled transport of molecules through a membrane

Just as dialysis allows substances to pass through a membrane while keeping others separated, Rheodialysis enables controlled chemical exchange with a sample during a rheological measurement.

This makes it possible to mimic processes such as ion diffusion, solvent exchange, enzyme exposure, pH changes, or nutrient transport while continuously monitoring material behavior.

Many soft materials are designed to respond to their environment.

For example:

Alginate Hydrogels
Alginate, derived from seaweed, is widely used in drug delivery, tissue engineering and cell encapsulation. During exposure to calcium ions, the material gels through Ionic crosslinking. Rheodialysis allows researchers to monitor this gelation process in real time while measuring the evolving viscoelastic properties.

Food Digestion Studies
Food structures do not only experience mechanical deformation during consumption. They are simultaneously exposed to changing pH values, salts and digestive enzymes. Rheodialysis enables researchers to study how food texture and structure change under conditions that more closely resemble digestion.

Pharmaceutical Formulations
Drug delivery systems often rely on diffusion-controlled processes. With Rheodialysis, researchers can investigate how buffer solutions, ions or other reagents influence material structure and release behavior while mechanical forces are applied.

These examples demonstrate why controlling chemistry and shear simultaneously can provide insights that conventional rheological measurements cannot capture.


With Rheodialysis, researchers can:

✔ Control chemical diffusion rates via pump settings and concentration
✔ Identify precise gelation points during Ionic exchange
✔ Model real-world processing conditions more accurately

As shown in the new white paper, the convergence of oscillatory phase angles at different frequencies can pinpoint the exact gel point during in-situ Ionic exchange.

DOWNLOAD THE NEW WHITEPAPER:

Rheodialysis technology for NETZSCH Kinexus Herometer enables real-time chemical environment changes during soft material testing.
The liquid, and thus the ions, flows through either a peristaltic or syringe pump and is directed through the membrane into the sample, where the ions diffuse through the latter. This enables a change in the chemistry of the sample in real time during rheological characterization without the sample being physically damaged by the flow of liquid.
The Rheodialysis approach: (a) A rheometer is equipped with a custom designed flow cell incorporating a porous membrane to allow buffer exchange of sample during rheological testing. (b) Among other uses (see below) this can be used to induce and probe gelation in-situ. (c) Pilot data of a model biopolymer solution that forms a gel during Ionic buffer exchange under oscillatory testing. Convergence of the oscillatory phase angles (yellow star) at different frequencies identifies the precise point of gelation.

Why Choose Rheodialysis for NETZSCH Kinexus?

Almost all soft materials ‒ biological or industrial ‒ are highly sensitive to mechanical StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress and their chemical surroundings. This rheology system uniquely enables you to:

Take a look at our white paper if you would like to learn more about the Rheodialysis Approach:

Join us in advancing open-source Rheodialysis!

Collaborate, contribute ideas, and help shape the future of this accessible research accessory.

Get in touch

Key Benefits of Rheodialysis

Rheodialysis: An Experimental Platform for Changing a Sample’s Chemical Environment during Rheological Testing

Please accept Marketing Cookies to see that Video.

In this webinar we will present the rheodialysis technique, which extends the capabilities of standard rheology by incorporating a customised flow cell with a porous membrane into a parallel plate rheometer. This approach allows a sample’s chemical environment to be exchanged, while simultaneously probing its mechanical properties.

Cutting-Edge Applications for Rheodialysis Technology

Why should you decide for a NETZSCH Kinexus Shear Rheometer?

FeatureBenefit
Modular, open design with easy sample accessEffortless cartridge swapping with dedicated rheology accessory ensures quick transitions between tests
Optimized rheology accessory fit for Kinexus onlyEliminates adaptation challenges, guaranteeing precise chemical-mechanical coupling measurements
Proprietary rSpace software controls automationSynchronizes chemical environment changes and rheological measurements for streamlined experiments
High sensitivity and dual-action shear and axial testingEnables comprehensive investigation of complex fluids, soft solids, and dispersions

Contact Us to Learn More

Discover how rheodialysis technology for your NETZSCH Kinexus rheometer can revolutionize your rheological testing of chemically sensitive soft materials. Discuss custom applications for pharmaceutical, healthcare, food, and material science innovations with our experts!

Join us in advancing open-source Rheodialysis!

Collaborate, contribute ideas, and help shape the future of this accessible research accessory.

Get in touch

FAQs about the NETZSCH Rheometer Service

Yes – we also support you with method development! Our experts possess in-depth know-how in rheology and thermal analysis and work closely with you to design the ideal measuring method for your specific application.

Once the method has been developed, our NETZSCH applications laboratories can carry out contract testing for a wide range of industries and research centers. Equipped with state-of-the-art rheometers and thermal analysis instruments, we ensure accurate and reproducible results tailored to your needs.

Consult with the experts to develop the best-suited measuring method for your specific needs.

We offer:

  • Installation and Commissioning
  • Relocation of your instrument
  • Maintenance and inspection
  • Calibration
  • Repair
  • Comprehensive training from basic to advanced use of the instrument – on-site and online.

Please note that our service may vary from region to region. Our Remote Service is available worldwide.

Yes, we offer maintenance contracts for your instruments according to the different regional and individual customer requirements. Please feel free to contact our Service Department or take a closer look at our website section Service-Level Agreement - NETZSCH Analyzing & Testing.

Furthermore, we offer an Unlimited Warranty for Kinexus Prime instruments!

We offer online training via our NETZSCH Online Academy (NOA), one-on-one remote training and on-site training at your location or our training centers. Simply contact your sales representative or go to Know-How - NETZSCH Analyzing & Testing.

Subscribe to our newsletter

Get exclusive insights into brand new applications & trends in thermal analysis.

Subscribe now
AI Overview
An error occurred. Please try again.