Determining the Stationary Heat Transfer Properties of Complex Building Components and Finished Products

HotBox Test Chambers Made by NETSCH TAURUS Instruments

In a world increasingly focusing on sustainability, energy efficiency, and safety, accurate knowledge of the heat transfer properties of building materials is crucial. Whether it's about the insulation of buildings, the efficiency of windows and doors, or the overall energy balance of facades, precise determination of these properties is essential. This is where the innovative HotBox test chambers come into play – the ultimate solution for measuring and analyzing the heat transfer properties of wall elements, walls, windows, and doors.

Along with different guarded hot plate systems, NETZSCH TAURUS today also offers large, standard-compliant test chambers capable of accommodating compact and complex components such as facade elements and masonry for determination of the Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity as well as the fire behavior. Hotbox systems (TDW) allow for measurement of the thermal transmission coefficients (U values) of larger and more complex building components, such as doors, windows, facades, etc. The test chambers are designed in accordance with various standards like DIN EN 1934, DIN EN ISO 8990, DIN EN 1946-4, DIN EN ISO 12567, DIN EN 12412-2 and ASTM C1363.

What Is a HotBox and How Does it Work?

A hotbox is a test system for determining the heat transfer properties of wall elements, walls, windows and doors. In a hotbox, real-world conditions as they would exist for a building wall are simulated: In practice, the both conditions inside the building and on the outside can be simulated. This means that temperature, humidity, air speed and radiation properties on both sides of the test wall must be detectable and precisely adjustable.

There are usually two test chambers (warm and cold sections); positioned between them is positioned a test frame with the sample. Stone walls to be tested are first bricked onto a base and then dried in drying chambers; windows, doors or facade parts are mounted directly on the test frame. The prepared test frame is inserted between the warm and cold sections and can then be measured.

In our HotBox systems, homogeneity of the flow and temperature profiles is guaranteed to be in accordance with standards. This means that the same temperature and air speed must prevail on the test wall at every point of the warm and cold sections. NETZSCH Taurus Instruments offers two different systems to this end: The TDW 4040 and the TDW 4240. We will explain the difference later in the article.

TDW 4240 test chamber open with adjustable test masks for windows, showcasing a modern design for heat transfer testing.
Figure: TDW 4240 test chamber (open) with test masks for windows

What Purpose Do HotBox Tests Serve?

The heat transfer through a brick wall or a window part is defined by the U-value: The lower the U-value, the lower the lost heat-flow and the better the insulation properties of the building part. The U-value is therefore a measure of the energy efficiency of parts of a building envelope such as brickwork, facades, windows and doors. Manufac­turers have to specify the U-value of their products.

Difference to Conventional Methods for Measuring Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.Thermal Conductivity

In contrast to conventional analysis methods for determining Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity – e.g., laser flash or plate method – these hotbox test chambers not only take the heat conduction through the material itself into consideration, but also the heat transfer conditions that are influenced by environmental factors such as material surface structures and ambient conditions. The surface structures of walls or transmission properties of window panes, for example, thus have direct influence on the effective heat transfer.

The measurement result is either the effective Thermal ConductivityThermal conductivity (λ with the unit W/(m•K)) describes the transport of energy – in the form of heat – through a body of mass as the result of a temperature gradient (see fig. 1). According to the second law of thermodynamics, heat always flows in the direction of the lower temperature.thermal conductivity of the entire test wall (heat-flow method) or the U- or k-value (heat transmission coefficient) as it relates to the heat flow between the air of the warm and cold sections (method with protected hotbox).

TDW 4040 or 4240? Your Choice!

NETZSCH TAURUS Instruments' hotbox test chambers offer various systems, including those with heat flux sensors and combinations of hotbox systems, to perform these measurements.

Various building materials, including bricks and concrete blocks, highlighting their texture and heat transfer properties for construction efficiency.

The TDW 4040 Test Chamber

NETZSCH has two standard test chamber systems: The TDW 4040 is the test Chamber for Determining the Stationary Heat Transfer Properties with a Heat Flow Meter in Accordance with DIN EN 1934.

HotBox test chamber TDW 4040 with heat flow meter for measuring stationary heat transfer properties of building materials.
Figure: HotBox test chamber with heat flow meter: the TDW 4040
Compact NETZSCH TDW 4040 test chamber for measuring stationary heat transfer properties of building materials with precise temperature control.
Figure: TDW 4040

The compact TDW 4040 test chamber is designed for testing brickwork (such as brick, lime sand brick, concrete, or aerated concrete) and basically simulates the temperature and the natural convection inside and outside a building. The software for control, data logging and analysis for determining stationary heat transfer properties is included in the test system.

The compact test chamber consists of a cold and a warm section, the hotbox and a test frame with test mask that is positioned between the two sections of the chamber. Both sections contain heat exchangers for temperature control and air deflectors with radial fans to generate the necessary convection.

Graphs displaying U-values and sensor data from NETZSCH HotBox test chamber software, essential for thermal analysis in building materials.
Software screenshots: left: Main window with overview of the main values and graph of the U-value over time (optional temperature difference or deviation); right: Graph of a single sensor value

The TDW 4240 Test Chamber

With the TDW 4240, we offer another test chamber system for determining stationary heat transfer properties. Unlike the TDW 4040, it uses the method with a controlled hotbox in accordance with standards like DIN EN ISO 8990, DIN EN 1946-4, DIN EN ISO 12567, DIN EN 12412-2, ASTM C-1363. 

The compact TDW 4240 test chamber is designed for testing elements and components used in construction, such as windows, profiles, doors, brick walls and domes.  

Close-up of a brick wall featuring a modern window, illustrating building insulation and energy efficiency.
Controlled HotBox test chamber TDW 4240, ideal for testing building components' heat transfer properties for energy efficiency.
Figure: HotBox test chamber with with a controlled hotbox: the TDW 4240
NETZSCH TDW 4042 HotBox test chamber designed for testing heat transfer properties of building materials, ensuring energy efficiency.
Figure: TDW 4042

Depending on the requirements, the humidity of the two chamber segments can also be adjusted. The selection of all parameters, recording of all data, extensive evaluations, and printing of measurement protocols are carried out with the standard TDW 4040 Hotbox software via the measurement and control unit.

Summary

The significance of NETZSCH HotBoxes cannot be emphasized sufficiently, especially at a time when the carbon footprint and energy efficiency of buildings are taking center stage. By simulating real-world conditions, these test chambers enable accurate analysis of the heat transfer, vital for the development of energy-efficient and environmentally friendly building products. This not only contributes to reducing carbon emissions but also helps lower operational costs and enhance the quality of life within buildings.