General Properties
Short Name: MF
Name: Melamine-Formaldehyde Resin
Melamine-formaldehyde resins (MF) also belong to thermosets (aminoplasts). Since Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing occurs by polycondensation, a reaction product, in this case water, is released during the reaction. The endothermal effect due to water evaporation overlaps the ExothermicA sample transition or a reaction is exothermic if heat is generated.exothermal effect of the cross-linking reaction. Therefore, measurements of polycondensation reactions are carried out in pressure-tight crucibles (here high-pressure steel crucibles).
Structural Formula

Properties
NETZSCH Measurement

| Sample Mass | 24.79 mg |
| Heating Rates | 10 K/min |
| Crucible | High-pressure steel crucible, closed |
| Atmosphere | N2 (40 ml/min) |
Evaluation
The above plot shows a DSC curve from a single heating of a melamine formaldehyde resin (MF). The Glass Transition TemperatureThe glass transition is one of the most important properties of amorphous and semi-crystalline materials, e.g., inorganic glasses, amorphous metals, polymers, pharmaceuticals and food ingredients, etc., and describes the temperature region where the mechanical properties of the materials change from hard and brittle to more soft, deformable or rubbery.glass transition at approx. 61°C (midpoint) is overlapped by a large endothermal enthalpy RelaxationWhen a constant strain is applied to a rubber compound, the force necessary to maintain that strain is not constant but decreases with time; this behavior is known as stress relaxation. The process responsible for stress relaxation can be physical or chemical, and under normal conditions, both will occur at the same time. relaxation peak (peak temperature 69°C) and is immediately followed by an ExothermicA sample transition or a reaction is exothermic if heat is generated.exothermal Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing with a peak temperature of approx. 136°C and a reaction enthalpy of 48 J/g. A temperature-modulated DSC (TM-DSC) measurement (not presented here) would be able to separate the reversing Glass Transition TemperatureThe glass transition is one of the most important properties of amorphous and semi-crystalline materials, e.g., inorganic glasses, amorphous metals, polymers, pharmaceuticals and food ingredients, etc., and describes the temperature region where the mechanical properties of the materials change from hard and brittle to more soft, deformable or rubbery.glass transition from the non-reversing endothermal RelaxationWhen a constant strain is applied to a rubber compound, the force necessary to maintain that strain is not constant but decreases with time; this behavior is known as stress relaxation. The process responsible for stress relaxation can be physical or chemical, and under normal conditions, both will occur at the same time. relaxation and the ExothermicA sample transition or a reaction is exothermic if heat is generated.exothermal reaction peaks.