Highlights
Test Device for Flammability of Plastics for Parts in Devices and Appliances
UL 94 is one of the most widely recognized flammability standards for plastics. It defines methods to classify materials based on how they burn in different orientations and under different conditions. NETZSCH offers dedicated UL94 flammability test instruments designed to perform the full range of UL 94 classifications under controlled and repeatable conditions:
- ASTM Standards: ASTM D635, D3801, D4804, D5048, D4986, ASTM D5025, ASTM D5207
- European Standards: EN 60695 Part 11-10, EN 60695 Part 11-20, EN 60695 Part 11- 3, EN 60695 Part 11-4, IEC EN 60707
- ISO Global Standards: ISO 1210, ISO 9772, ISO 9773, ISO 10093, ISO 10315
Well thought-out details along with the use of high-quality materials guarantee the UL 94 a long product life while reduing the need for cleaning and maintenance, increasing safety and greatly simplifying day-to-day work at the laboratory.

Understanding Fire Behavior: A Four-Part Webinar Series
Method
- Sample holder for rod-shaped and flat samples
- Semi-automatic calibration
- Automated measurement process
- Operator guidance via high-resolution 10" touch screen with brilliant colors and catchy icons for menu functions
- Accessories for standard tests included (options see separate technical datasheet)
- Closed combustion chamber with exhaust fan, black interior walls and mirrors
- Material: stainless steel, bead blasted
- Large sliding window with fire-resistant glazing on the front door
- Adjustable burners with adjustable tilt angle (0°, 20°, 45°)
- Calibration aid for burner flame


- Semi-automatic operation: Electrically driven spindle system for positioning the samples and the burner for horizontal and vertical tests including frame and wire mesh
- Additional manual operation: Two openings with panels on the front for manual access allowing manual positioning and adjustment of the burner
- Sample holder for horizonal and vertical tests
- Processor-controlled timer
- Remote control with reset button for time measurement
- Metal dipstick
- Processor-controlled flowmeter, pressure regulator and pressure gauge
- Gauges for flame height and samples
- Base frame with rolls and drawer (option)
- Exhaust piping, aluminum link hose with draft diverter (option)
What is the difference between the NETZSCH UL 94 Supreme and UL 94 Classic flammability testing devices?
Specifications
| Measurement method | Test device for assessing the flammability of plastics for parts in devices and appliances in accordance with ISO UL 94 5th an 6th Edition, DIN EN 60695 Part 11-10, DIN EN 60695 Part 11-20, DIN EN 60695 Part 11- 3, DIN EN 60695 Part 11-4, ISO 9772 and ISO 9773 |
|---|---|
| Sample holder | Sample holder for horizontal and verticals tests with sample support, thermocouple holder and wire grid |
| Burner |
|

Consultancy & Sales
Do you have further questions about the instrument or the method and would like to speak to a sales representative?
Service & Support
Do you already have an instrument and need technical support or spare parts?
Related Devices

Proven Excellence in Service
At NETZSCH Analyzing & Testing, we offer a comprehensive range of services globally to ensure the optimal performance and longevity of your thermoanalytical equipment. With a track record of proven excellence, our services are designed to maximize the effectiveness of your devices, extend their lifespan, and minimize downtime.
Unlock the full potential of your equipment with our tailored solutions, backed by years of industry expertise and innovation.