NETZSCH STA 449 Jupiter® thermal analysis instrument with touchscreen display and dual sample carrier, ideal for simultaneous DSC-TGA measurements.
Simultaneous Thermogravimetry

STA 449 F3 Jupiter®

Fascinating Flexibility in Thermal Analysis 

Show current instrument

The simultaneous thermal analyzer NETZSCH STA 449 F3  Jupiter® allows the measurement of mass changes and thermal effects between -150°C and 2400°C.

The high flexibility caused by the various sensors, the great variety of sample crucibles and the wide TGA-measuring range make the system applicable for analysis of all kinds of materials including also inhomogenous substances. Easily interchangeable sample holders allow the optimal system adaption to the diverse application areas (TGA, TGA-DTA and TGA-DSC measurements). Various furnaces, easy interchangeable by the user, cover the complete temperature range (please see accessories).
Through to the vacuum tight design measurements at defined atmospheres (e.g. inert) are possible. The system is controlled by a newly developed integrated digital electronic device. The analysis of measuring data runs under a standard PC and the well-proven Windows® software.

Two professionals collaborate at a table, reviewing charts and analyzing data on a tablet, emphasizing teamwork in research.

Request a Quote

Get a personalized offer now.

Request a Quote

Technical Data

Temperature range
-150°C to 2400°C
Tungsten furnace 
RT to 2400°C
High-speed furnace
RT to 1250°C
NETZSCH STA 449 Jupiter® thermal analysis instrument with digital display, ideal for simultaneous DSC-TGA measurements.

Heating and cooling rates:
0.001 K/min to 50 K/min
(dependent on furnace)

Weighing range:
35000 mg

TG resolution:
0,1 µg (over entire weighing range)

DSC resolution (depending on sensor type):
e.g. < 1 µW for DSC sensor type S and 0.5 µW for DSC sensor type E

Atmospheres:
inert, oxidizing, reducing, static, dynamic

Switch valve: 
for 2 purge gases and 1 protective gas

Vacuum-tight assembly:
up to 10-4 mbar

Coupling:
FT-IR, MS via Capillary or SKIMMER coupling

NETZSCH STA 449 Jupiter® thermal analysis instrument featuring dual measure capability and a digital display for precise data.
Laboratory setting with scientists in white coats working with advanced equipment, highlighting innovation and quality in research.

This instrument is LabV®️-primed

LabV® takes the data from your analytical instrument: It automatically imports all measurement data into a central and secure database solution, the LabV® software. This allows you to visualize the data in LabV®️ and to make them searchable. Your data will now be accessible from anywhere. Moreover you have the possibility to generate reports.

Stack of colorful, glossy brochures showcasing quality consulting services and project collaboration in detail.

Product Information

We do not only promise quality, but also individual consulting. Let us start your project together.

Request Information

Videos

Please accept Marketing Cookies to see that Video.

STA 449 F3  Jupiter® Simultaneous DSC-TGA sample carrier change

Please accept Marketing Cookies to see that Video.

Part 2 Sample Preparation Influencing Factors How to Setup an STA Measurement

You may also be interested in

AI Overview
An error occurred. Please try again.