06.09.2023 by Aileen Sammler

Introducing the New DMA 523 Eplexor®A High-Force Series for Large and High-Modulus Samples

After having launched the NETZSCH DMA 303 Eplexor in the low-force range, NETZSCH is proud to present a new stand-alone instrument series for dynamic mechanical analysis for high-force capabilities: The DMA 523 Eplexor® High-Force Series for the investigation of metals, ceramics and composites. 

Thanks to their modular design, these new high-force DMA instruments can accommodate add-ons to additionally carry out tests on properties such as fatigue, heat build-up, blow-out and Rolling ResistanceThe rolling resistance is a force resisting the motion when a body is rolling across a surface. This determines the slip resistance of, e.g., car or truck tires.rolling resistance.

Watch our 3D video and see for yourself:

Si prega di accettare i cookies di marketing per guardare il video.

Figure: The new NETZSCH 523 Eplexor® achieves force levels of up to twelve Kilonewtons, offering unmatched flexibility und robustness

The DMA 523 Eplexor® is designed to offer both static and dynamic force levels with a maximum ranging from ± 2000 N to ± 4000 N. This makes it an ideal choice for studying the dynamic-mechanical or simply static properties of rigid samples, including those with larger dimensions and even component parts.

Safety and efficiency are at the forefront of the DMA 523 Eplexor® design. The instrument features a unique blade spring system for effective shock absorption during high-force tests. Moreover, its optimized cooling control ensures minimal liquid nitrogen consumption during sub-ambient temperature operations.

 

Focus on Fatigue Applications

This high-force DMA is especially capable in fatigue tests and heat build-up. Besides the fresh design, the new NETZSCH 523 Eplexor® achieves force levels of up to twelve Kilonewtons, offering unmatched flexibility and robustness for larger samples and higher loads.

There are two types of DMA 523 Eplexor® instruments available, classified according to their force capacities: The DMA 523 Eplexor® 2000 N and DMA 523 Eplexor® 4000 N. These systems have a maximum static force of 6000 Newton. The dynamic force levels range from max. ± 2000 N to max. ± 4000 N:

Instrument TypeMax. Static ForceMax. Dynamic Force
DMA 523 Eplexor® (2000 N)6000 N± 2000 N
DMA 523 Eplexor® (4000 N)6000 N± 4000 N

Flexible, Easily Adjustable and Universally Applicable 

The new DMA Eplexor® series offers unmatched flexibility: It allows for easy upgrades to the basic instruments with a wide variety of additional options and accessories; force sensors are exchangeable, too. With the appropriate hardware and/or software add-ons, which can also be retrofitted, the DMA 523 Eplexor® can be converted into, for example, a Goodrich flexometer (ASTM D623), a 24/7 system with automatic sample changer for up to 160 samples in diverse modi, or an instrument for high-temperature application.  

The high-force Eplexor® DMA instruments consist of two independent drives for static and dynamic force. The static force is generated by a servomotor; the dynamic force by an electrodynamic shaker system. The two drives can be used independently, which allows for the Eplexor® high-force instruments to be used either as classical DMAs or as universal testing machines.

The DMA 523 Eplexor®: Designed to investigate metals, ceramics or composites. The instrument can be equipped with several cooling options, depending on your needs.
Bring the DMA 523 Eplexor® into your laboratory and explore its features from every angle – with only one click!

Simply scan the QR code and get a 3D model of the instrument directly on your mobile phone or tablet. With the help of the latest AR Technology (Augmented Reality), the 3D model can easily be placed in your laboratory in its original life size. 
 

Share this article: