NETZSCH Taurus Instruments system features an industrial design with ventilation ducts and a control panel, ideal for precise material analysis.
Fire Testing

SBI 915

Single Burning Item

Highlights

Fire Testing System for determining the reaction of building products to fire when exposed to thermal attack by a single burning item, in accordance with EN 13823

The SBI 915 from NETZSCH TAURUS Instruments GmbH is easy to operate, offering innovative control and data acquisition options in an intuitive format with ample user guidance. The high-resolution color touch display on the “SBI Control“ cabinet allows for measuring and control with the integrated Single Board Computer, Windows operating system and SBI software. There is thus no longer any need for manual controls such as switches, controllers or buttons; the status of the testing system is clearly displayed and the systems prevents any critical operating errors. The storage, analysis and recording of all test data is handled entirely via the control unit. Well thought-out details along with the use of high-quality materials guarantee the SBI test system a long product life and a low degree of wear and tear.

Our Quality Promise:

NETZSCH’s Unlimited Warranty

At NETZSCH, our commitment to quality goes beyond the instruments themselves. We understand that your investment in advanced technology is a long-term one, and and that’s why we offer something truly unique – our Unlimited Warranty.

Method

Test Setup

The product specimen is mounted on the trolley rig forming a room corner.

The specimen consists of two parts which form a rightangled corner. A triangular propane diffusion gas burner acts as the heat and ignition source.

Floor, specimen and burner are located on a trolley that can be removed from the room for easy mounting of the specimens.

Test Method

The sampleis exposed to flames with a heat release of 30 kW for a period of 20 minutes. Heat and smoke production is measured within the ducting for the exhaust hood, and flame spread is observed during the test.

Measurement

A hood collects the combustion gases. The gases are transported through a collector where the heat output is used for calculating the release rate (HRR), THR and FIGRA while the amount of smoke is used for calculating SPR, TSP and SMOGRA. Flame spread and burning droplets/particles are visually observed.

Schematic of a combustion testing setup, featuring main and auxiliary burners, a test specimen, and measuring equipment.

Specifications

Measurement methodBy a single burner item in accordance with EN 13823, Euroklassen A2, B, C and D
Assembly frame
  • Welded square tube construction, steel, painted, RAL 7012
  • Lined with calcium silicated panels, T: 2.0 cm
    • Dimensions (H x W x D): 245 cm x 148 cm x 148 cm
Auxiliary burner (Gas to be provided by the user)
  • Stainless steel, firmly mounted to the assembly frame
  • Sample protection shield of calcium silicate
  • Check valve, ignition burner, flame detector
  • Dimensions (W x D): 35 cm x 55 cm ± 0.5 cm
Collector
  • Insulation with mineral fiber plates, 5.0 cm
  • 2 air shields mounted with the exhaust hood
  • Dimensions (H x W x D): 70 cm x 58 cm x 58 cm
Customer support representative at a computer, smiling and engaged, highlighting NETZSCH's commitment to service excellence.


Proven Excellence in Service

At NETZSCH Analyzing & Testing, we offer a comprehensive range of services globally to ensure the optimal performance and longevity of your thermoanalytical equipment. With a track record of proven excellence, our services are designed to maximize the effectiveness of your devices, extend their lifespan, and minimize downtime. 

Unlock the full potential of your equipment with our tailored solutions, backed by years of industry expertise and innovation.

Software

Designed for data logging, processing and displaying the measurementresults in accordance with EN 13823

  • Graphical and numerical display of all test results
  • User guidance for test procedure
    • Graphic flow chart of test procedure
    • Dialogs with device-specific user instructions
    • Dialog for input of all relevant information according to standard
    • Dialog for automated adjusting of gas analysis
    • Conducting the test with automatic activation of valves and burner
    • Monitoring of the test with regard to HRR and excess temperature in the exhaust duct
    • Online calculation and display of all data relevant to the test, such as HRR, THR, SPR, TSP, FIGRA
    • Storage of the test data in EXCEL-compatible file
  • Calibration of gas analysis
    • Completely automated adjusting procedure
    • Control of calibration gases via the software
    • Start of adjustment procedure upon reaching stability
A red Formula 1 car is in the pit, surrounded by team members in red and black uniforms performing a tire change during a race.

Consultancy & Sales

Do you have further questions about the instrument or the method and would like to speak to a sales representative?

Service & Support

Do you already have an instrument and need technical support or spare parts?

Downloads and Media

AI Overview
An error occurred. Please try again.