Hyphenated Techniques - Evolved Gas Analysis

PERSEUS® TG 309 Libra®

The Perfect TGA-FT-IR Coupling Solution

Evolved Gas Analysis (EGA) is the perfect tool for characterizing the thermal behavior of organics, inorganics, or polymers in more detail, elucidating the chemistry behind the processes.

The PERSEUS® TGA 309 Libra® is robust and stands out by virtue of its high performance, compactness and attractive price. This instrument integrates the small but powerful FT-IR with the TGA and has the potential to fit into any laboratory – be it in universities or industry, quality assurance or development.

Any existing NETZSCH TG 309 Libra®Supreme and the TG 309 Libra®Select system can be upgraded with the PERSEUS® coupling.

The PERSEUS® TG 309 Libra® can be employed for the following application areas:

Two professionals analyze data on a tablet and documents, discussing project details in a collaborative workspace.

Request a Quote

Get a personalized offer now.

Request a Quote
NETZSCH TC 309 Libra device for thermal analysis, featuring a user-friendly touchscreen and advanced testing capabilities.

Affordable Gas Analysis

The unrivaled instrument alliance serves as an innovative coupling technique, even for a narrow budget. It has what it takes to become an integral part of any laboratory and may well become indispensable for future needs.

No Liquid Nitrogen required

The DLaTGS (deuterated L-alanine doped triglycine sulfate) detector operates without the need for liquid nitrogen. This system is thus particularly well-suited for test runs with an autosampler (ASC) or long-term measurements.

Technical Data

Heating of transfer tube
two options (temperature-controlled; using a constant voltage supply source)
Heating of gas cell
200°C in maximum,
software-controlled
Detector
DLaTGS

Gas cell length/volume:
70 mm / 5.8 ml (no mirror inside, beam conforming design)

Spectral range of FT-IR data:
350 cm-1 to 8000 cm-1 KBr windows

Gas cell:
KBr windows, sealingViton©

To view the technical data of the TG 309 Libra®, please click HERE.

NETZSCH TC 309 Libra® thermal analysis instrument with a touchscreen display for precise material characterization and testing.

Please accept Marketing Cookies to see that Video.

The PERSEUS® coupling interface is distinguished by its exceptional design and user-friendly operation, even with automatic sample changer.

It eliminates the need for a separate transfer line by integrating a heated gas cell directly connected to the furnace's gas outlet through a heated tube. The short gas path's low volume ensures rapid response, which is particularly beneficial when dealing with condensable evolved gases. Moreover, the PERSEUS® is notable for its exceptionally small footprint.

The video shows the fast and straight forward disassembling of the Bruker Alpha II to enable ATR measurements with the same instrument within a few minutes.

Stack of glossy brochures showcasing NETZSCH Analyzing and Testing, highlighting quality consulting services.

Product Information

We do not only promise quality, but also individual consulting. Let us start your project together.

Request Information

Videos

Please accept Marketing Cookies to see that Video.

PERSEUS®® TG 209 F1 TGA-FT-IR Coupling

Please accept Marketing Cookies to see that Video.

TG209 F1 PERSEUS®®-Coupling 

Please accept Marketing Cookies to see that Video.

NETZSCH Analyzing and Testing at the Analytica 2016 
AI Overview
An error occurred. Please try again.