PERSEUS® STA 509 Jupiter® with Direct Coupling
The Revolution in STA-FT-IR Coupling
Highlights
Seamless STA-FT-IR Coupling for Advanced Gas Analysis
PERSEUS® is the name given to the unique alliance between a NETZSCH simultaneous thermal analyzer (STA) and a compact yet powerful FT-IR spectrometer from Bruker Optics. This intelligent integration sets new standards in hyphenated thermal analysis.
Thanks to its direct coupling design, the PERSEUS® interface eliminates the need for a separate transfer line. The heated FT-IR gas cell is directly connected to the furnace via a short heated tube, creating a minimal gas path volume. This design ensures fast response times and is particularly advantageous for analyzing condensable or reactive evolved gases.
The PERSEUS® STA 509 Jupiter® stands out with its high sensitivity, robust performance, and compact footprint. Its modular concept is ideal for demanding research and development environments as well as for routine quality control in both academia and industry.
Existing NETZSCH STA 509 Jupiter® systems can be easily upgraded with the PERSEUS® coupling, unlocking advanced analytical capabilities without the need for major instrument replacement.
Method
Fourier Transform Infrared (FT-IR) Spectrometers Coupled to Thermal Analysis
Thermal analysis provides ideal tools for the characterization of a variety of organic and inorganic solids and liquids. Thermodynamic transitions, Thermal StabilityA material is thermally stable if it does not decompose under the influence of temperature. One way to determine the thermal stability of a substance is to use a TGA (thermogravimetric analyzer). thermal stability, Decomposition reactionA decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. decomposition, and chemical reactions can be detected and quantified with high accuracy over a broad temperature range.
In some cases, however, information about the type of evolved gases is needed to gain a clearer understanding of the chemistry behind the processes. Coupling thermal analysis with powerful infrared spectroscopy for gas analysis bridges this gap. It allows for a deeper insight into the material’s behavior and provides a spectral fingerprint of the gases evolved from the sample when heated.
The Proteus® software for thermal analysis and the OPUS software for FT-IR measurements are seamlessly integrated to enable efficient Thermal Analysis-to-FT-IR coupling. The temperature and time correlations of all experimental data are carefully preserved throughout the process.
Infrared spectroscopy
Infrared spectroscopy is a classical technique based on the absorption of infrared radiation by molecular bond vibrations. This absorption occurs when bonds vibrate in specific ways. However, only those vibrations that cause a change in dipole moment can interact with IR light. This is why most substances produce a characteristic spectrum, while homonuclear molecules — such as O₂ and N₂ — or noble gases do not show fundamental IR absorption bands, due to the absence of dipole moment changes during VibrationA mechanic process of oscillation is called vibration. Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. In many cases, vibration is undesirable, wasting energy and creating unwanted sound. For example, the vibrational motions of engines, electric motors, or any mechanical device in operation are typically unwanted. Such vibrations could be caused by imbalances in the rotating parts, uneven friction, or the meshing of gear teeth. Careful designs usually minimize unwanted vibrations.vibration.

Working principle of a FT-IR spectrometer
An infrared light beam, depicted in the diagram as coming from the source on the right, is split into two paths by a beam splitter. One path is directed toward a fixed mirror and reflected, while the other is reflected by a moving mirror.
After reflection, the two beams are recombined and interfere with each other. The resulting interference pattern depends on the distance between the two mirrors — which changes as the moving mirror shifts position — and the frequencies present in the beam.
This process generates an interferogram, a signal typically characterized by a central burst and flat wings. The central burst occurs when both mirrors are equidistant from the beam splitter, allowing all frequencies to interfere constructively.
Finally, the interferogram is mathematically transformed into a spectrum using a Fourier Transform, revealing the sample’s infrared absorption characteristics.
To ensure highly sensitive detection of the gases evolved, a gas cell with a long path length and low volume is required. The longer the path length, the more molecules interact with the IR beam. Conversely, the gas concentration is also influenced by the volume of the gas cell. The smaller the volume, the higher the concentration of the gases evolved.
Developed in collaboration between NETZSCH Analyzing & Testing and Bruker Optics, the beam-conforming metal gas cells with optimized gas flows perfectly combine these requirements.
Another advantage of this design is the absence of an internal mirror, which prevents particle condensation and thus avoids any loss of detection sensitivity caused by a contaminated mirror surface.

Type | Gas cell for PERSEUS® coupling (only internal) |
|---|---|
Length | 70 mm |
Volume | 5.8 ml |
Windows | KBr windows |
Windows removal for cleaning purpose | ✅ |

Over 30 Years of Successful Cooperation
For over 30 years, NETZSCH and Bruker have collaborated to provide integrated solutions for thermal analysis and gas analysis. This longstanding partnership combines NETZSCH's expertise in thermal analysis with Bruker's leadership in FT-IR technology, offering customers reliable, high-quality systems tailored to their needs. Together, we deliver innovative, user-friendly solutions from a single source, ensuring seamless operation and exceptional support.
Advantages of our Cooperation at a Glance:
- Seamless integration: Optimized coupling of NETZSCH thermal analyzers with Bruker FT-IR spectrometers for reliable and efficient evolved gas analysis.
- Proven expertise: Decades of joint experience ensure high-quality, innovative solutions tailored to customer needs.
- Single-source convenience: Fully compatible systems with comprehensive support from both partners.
- Enhanced performance: Precise coordination of instruments delivers accurate and reproducible results.
- Continuous innovation: Collaboration fosters the development of cutting-edge technologies and features for advanced analysis.
- Effortless Compatibility with Bruker's OPUS Software: At NETZSCH, we offer seamless compatibility with Bruker’s OPUS software, allowing for a smooth workflow between both systems. This ensures an integrated and efficient experience, making the most out of both instruments.
Specifications
software-controlled

- Affordable Gas Analysis
The unrivaled instrument alliance serves as an innovative coupling technique, even for a narrow budget. It has what it takes to become an integral part of any laboratory and may well become indispensable for future needs. - No Liquid Nitrogen required
The DLaTGS (deuterated L-alanine doped triglycine sulfate) detector operates without the need for liquid nitrogen. This system is thus particularly well-suited for test runs with an autosampler (ASC) or long-term measurements. - No Separate Transfer Line
The built-in heated gas cell is directly connected to the gas outlet of the furnace via a heated tube. The low volume of this short gas path guarantees fast response and is quite advantageous in cases where condensable evolved gases are present. - Space-Saving Design
No separate FT-IR spectrometer is necessary, the footprint of the PERSEUS® STA 509 Jupiter® coupling is identical to that of an STA 509 Jupiter® alone. This makes the coupled system ideally suited for labs in which space is scarce.
Gas cell length/volume:
70 mm / 5.8 ml (no mirror inside, beam conforming design)
Spectral range of FT-IR data:
350 cm-1 to 8000 cm-1 KBr windows
Gas cell:
KBr windows, sealing Viton©
To view the technical data of the STA 509 Jupiter®, please click HERE.


Proven Excellence in Service
At NETZSCH Analyzing & Testing, we offer a comprehensive range of services globally to ensure the optimal performance and longevity of your thermoanalytical equipment. With a track record of proven excellence, our services are designed to maximize the effectiveness of your devices, extend their lifespan, and minimize downtime.
Unlock the full potential of your equipment with our tailored solutions, backed by years of industry expertise and innovation.
Software
Bruker OPUS and NETZSCH Proteus® – Unrivaled Combination for Maximum Ease of Use
The alliance between the NETZSCH Proteus® software and the OPUS FT-IR software is based on synchronized data exchange, enabling coordinated operation of the coupled systems. Measurements are started via the NETZSCH Proteus® software, which simultaneously triggers data acquisition in OPUS. Users only need to input the command for measurement start and data acquisition once; both OPUS and Proteus® will then operate with the predefined parameters. Online data collection is fully synchronized, ensuring precise time and temperature correlation between all signals from the two coupled instruments during evaluation. The two software packages can be operated from a single computer, giving users access to the full range of data evaluation and results display options in either environment at any time
Find out even more about the software:
- Full software integration – online data exchange between the two instrument software packages during the running experiment
- Seamless instrument control, measurement definition for TGA and FT-IR entirely controlled by Proteus® software
- Segmental activation or deactivation of the FT-IR coupling with one mouse click
- Automatic saving of data sets for both measurements (TGA and FT-IR) with identical file names (but different extensions) in the same directories
- Measurements with automatic sample changer allow for individual FT-IR measurement parameter for each position
- Conjoint presentation of the Gram-Schmidt plot plus up to 30 pre-selected traces together with thermal analysis curves in Proteus® software during the experiment
- Online evaluation (SNAP SHOT) of TGA/STA/DSC measurements already including FT-IR data during the measurement
- Trace calculations with evaluation of characteristic temperatures and peak areas together with TGA and DSC curves
- Combined analysis graphics of thermal analysis and FT-IR signals
- Multi-component search in OPUS
- Identification by various gas phase librarys, e.g. TGA-FT-IR library of polymers by NETZSCH

Downloads and Media
Application Literature
Our latest blog articles
- 25.06.2026
Tracking Down the Chemistry of PUR Powder Coatings with TGA-FT-IR and DSC

- 19.05.2026
Understanding Cement Raw Materials: STA-FT-IR Analysis for Deeper Insight into Thermal Processes

- 21.04.2026
More Transparency in Combustion Gas Analysis: OMEGA 5 FT-IR Coupling on the NETZSCH TCC 918 Cone Calorimeter

- 17.03.2026
Moisture Matters: Understanding the Decomposition of Potassium Clavulanate Using TGA-FT-IR