04.03.2021 by Dr. Natalie Rudolph, Silvia Kliem, Dr. Catherine A. Kelly
Making Biopolymers Processable Using Thermal Analysis and Rheology

Biopolymers are an attractive alternative to polymers derived from fossil fuel and are mainly used by the packaging industry today. However, their CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released.crystallization behavior makes it more difficult to process these new materials. Learn how thermal analysis and rheology provide solutions to study the relevant material properties.
Never before was the plastics industry as driven by sustainability as it is now. The mounting pressure from society and legislation is weighing particularly heavy on the packaging industry demanding more sustainable alternatives.
What are biopolymers?
The term biopolymers includes bio-based polymers, biodegradable polymers, which could be oil-based, as well as the combination of both: bio-based and biodegradable at the same time. Bio-based polymers have a low carbon footprint that can be even further improved if the materials are recycled. Biodegradable plastics are sometimes criticized, because they often do not decompose in the environment, but rather under very controlled conditions in composting plants.
Therefore, materials like polyhydroxybutyrate-hydroxyvalerate (PHBV) are particularly interesting as they are bio-based and biodegradable at room temperature. For example, it will decompose in soil over the duration of just a few weeks to a month. Polyhydroxybutyrate (PHB) is generated by specific bacteria as a form of energy storage. The pure material has a high Crystallinity / Degree of CrystallinityCrystallinity refers to the degree of structural order of a solid. In a crystal, the arrangement of atoms or molecules is consistent and repetitive. Many materials such as glass ceramics and some polymers can be prepared in such a way as to produce a mixture of crystalline and amorphous regions.crystallinity of up to 80%, which makes it rather brittle and difficult to process conventionally. However, copolymerization within the bacteria produces PHBV with good mechanical properties.
Challenge #1: Secondary crystallization at room temperature
Unfortunately, these properties change during the service life of the manufactured products because of continued CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released.crystallization and thus embrittlement. This often happens within a few days and makes the material unsuitable for even short-term use. One solution is adding other polymers or oligomers that reduce or even hinder the secondary CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released.crystallization at room temperature. Ideally, the added material is also bio-based.
One such suitable plasticizer for PHBV is polyethylene glycol (PEG) [1]. In a study performed at the University of Birmingham in the AMCASH and Jenkins’ laboratories, Dr. Kelly1,2 investigated the miscibility of this blend. The researchers produced various mixtures of PHBV and low-molecular weight PEG and studied the material behavior using a NETZSCH Kinexus Pro+ rotational rheometer. To study the miscibility, typically frequency sweeps are performed in oscillation and the measured storage moduli plotted over the corresponding loss moduli, on log scales, to obtain a Han plot. Han et al. stated that any miscible blend would exhibit a straight line comparable to the pure material and deviations from that line indicate immiscibility [2].
However, the PHBV-PEG blends studied here degrade during the measurements and therefore, this method can not be readily applied. Therefore, a modification used for thermally unstable systems was used, which was first proposed by Yamaguchi and Arakawa [3]. Time sweeps were performed at specific frequencies. The measurement conditions are summarized in Table 1 and the results of the time sweeps are shown in Figure 1 for the storage modulus.
Table 1: Measurement conditions
| Measurement Mode | Time sweeps in oscillation |
| Geometry | 20 mm parallel plates |
| Temperature | 185°C |
| Gap | 1 mm |
| StrainStrain describes a deformation of a material, which is loaded mechanically by an external force or stress. Rubber compounds show creep properties, if a static load is applied.Strain | 0.5% |
| Frequencies | 0.25 – 25 Hz |
| Premelt time | 5 minutes |

After the measurements and data collection were finished, both the storage and Viscous modulusThe complex modulus (viscous component), loss modulus, or G’’, is the “imaginary” part of the samples the overall complex modulus. This viscous component indicates the liquid like, or out of phase, response of the sample being measurement. loss modulus data were plotted against frequency for each 60 second interval. A master curve was then generated by superimposing the data. These calculated master curves were used to compute the corrected storage and Viscous modulusThe complex modulus (viscous component), loss modulus, or G’’, is the “imaginary” part of the samples the overall complex modulus. This viscous component indicates the liquid like, or out of phase, response of the sample being measurement. loss modulus at time t0 and to generate the Han plots, Figure 2. For all investigated blends, their miscibility was proven by a straight line comparable to that of the pure PHBV.

More details about the analysis as well as the use of the rheological data to compute the degradation rates can be found here!
Challenge #2: Processability into thin films
In another study performed at the Institut für Kunststofftechnik at the University of Stuttgart by Silvia Kliem, MSc3, bio-based citrate was studied as a plasticizer for use in film blowing. Due to the low viscosity and melt strength of pure PHBV, a suitable biodegradable additive is needed to improve its processability into thin films. The researchers blended the PHBV with different amounts of citrate (5 and 10 wt%) as a plasticizer as well as low amounts of polylactide (PLA). A NETZSCH DSC 204 F1 Phoenix® was used to study the effect of the additive on the CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released.crystallization behavior of the blend. The measurement conditions are summarized in Table 2.
Table 2: Measurement conditions
| Pan | Al, pierced lid |
| Sample weight | about 11 mg |
| Atmosphere | N2 |
| Temperature | -20°C to 200°C at 10 K/min (1. + 2. heating and cooling) |

Figure 3 shows the heating and cooling curves of the PHBV-PLA blend with and without citrate. It can be seen that the melting and CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released.crystallization enthalpy is comparable for all three compositions when normalized for the citrate weight content (analysis results omitted in graph for better clarity). The peaks at 175°C and 120°C are for the melting and CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released. crystallization of the PHBV, respectively. The much smaller peak at 150°C shows melting of the PLA component. Comparing the different curves further, it can be observed that the additive citrate shifts the melting and CrystallizationCrystallization is the physical process of hardening during the formation and growth of crystals. During this process, heat of crystallization is released. crystallization peaks to lower temperatures; in the case of 10 wt% citrate by almost 4 K. This has a significant effect on the degradation of the material during processing, as the extrusion temperature can be lower due to the plasticizer.
These analysis results were validated by film blowing trials. While the PHBV-PLA blends without plasticizer could not be expanded, the extrusion was improved with 5 wt% citrate. Only with 10 wt% was it possible to keep up a steady extrusion process and to reach a film thickness < 25 µm.
The whole study can be found here!
Rheology and Thermal Analysis suitable to analyze biopolymers
These two studies show examples of bio-based plasticizers for bio-based PHBV to create a fully degradable packaging material. It can be seen that both plasticizers have advantages for different applications that require different processing as trays compared to thin films. It was found that both rheological and thermoanalytical techniques can be applied to analyze the properties of biopolymers such as PHBV and especially their processability. It is especially helpful that both rheological and thermoanalytical methods require very little amounts of material compared to processing trials, but can give valuable information about their properties. Using the right techniques will help increase our understanding of this still relatively new class of materials and allow the steady improvement and market maturity that we so urgently need.
1About AMCASH at the University of Birmingham
The AMCASH project, which is a part-funded ERDF program, is co-ordinated through the School of Metallurgy & Materials at the University of Birmingham. The project offers regional SME organizations technical assistance of typically a 2-day duration, within materials science related projects. Learn more here!
2About the Jenkins’ laboratory at the University of Birmingham
Activity mainly concerns the relationship between chemical structure, processing, microstructure and the physical properties of thermoplastic polymers (numerous polymers, blends and thermoplastic composites), and furthermore, how the properties can be influenced by each of these aspects. Learn more here!
3About the Institut für Kunststofftechnik at the University of Stuttgart
The expertise of the Institut für Kunststofftechnik under the direction of Prof. Dr.-Ing. Chrsitian Bonten comprises the entire field of plastics technology: material engineering, processing technology (mechanical and process engineering) and product engineering. Learn more here!
Sources
[1] Kelly AC, Fitzgerald AVL, Jenkins MJ. Control of the secondary crystallisation process in poly(hydroxybutyrate-co-hydroxyvalerate) through the incorporation of poly(ethylene glycol), Polymer Degradtaion and Stability. 2018; 148: 67-74, https://doi.org/10.1016/j.polymdegradstab.2018.01.003
[2] Yang H, Han CD, Kim JK. Rheology of miscisble blends of poly(methylmethacrylate) with poly(styrene-co-acrylonitrile) and with poly(vinylidene fluoride), Polymer. 1994; 35(7): 1503-1511
[3] Yamaguchi M,Arakawa K. Effect of thermal degradation on rheological properties for poly(3-hydroxybutyrate). Eur. Polym. J. 2006;42(7):1479-86