NETZSCH DMA 303 Explorer, a dynamic mechanical analyzer, features a touchscreen interface for precise material testing.
Dynamic-Mechanical analyser

DMA 303 Eplexor®

Use Dynamic-Mechanical Analysis to gain insights into your material’s mechanical properties

Highlights

The most user-friendly DMA you have ever experienced

Controlled Force Range up to 50 N (static and dynamic) 

Our material testing system is designed for precision measurements on very stiff samples with a controlled force range, both static and dynamic, of up to 50 N. The full resolution is available throughout the entire force range, resulting in precise and reliable data.

Temperatures of up to 800°C on the Sample

Featuring the broadest temperature range of -170°C to 800°C and homogeneous temperature distribution.

Time Saving ‒ Fast Heating and Cooling

With its thin-walled 3D-printed silicon carbide furnace lining, our system reduces waiting times with fast heating and cooling and allows for homogeneous temperature distribution due to two independent temperature control loops.

Instant access to important information ‒ Color info display and LED status bar

The integrated LED status bar keeps you informed with regard to the course of the measurement as well as the force, frequency and temperature used.

Back-friendly - highly ergonomic design

 The height of the sample holder area can be adjusted, allowing ergonomic work regardless of the user's height or preference for standing or sitting.

Easy on the eyes - Illuminated sample holder area
The integrated light source provides additional illumination and makes specimen and sample holder exchange even more comfortable

Intuitive and tool-less. No more cumbersome exchanging of sample holders and specimens
The instrument allows for convenient switching between a variety of sample holders. It auto-detects sample holders and chooses the correct calibration. The exchange is tool-free and, thanks to fixed guides, sample holders are easy to install. 

Three advanced analytical instruments are lined up, featuring sleek designs with LCD touchscreens for efficient data analysis.

Dynamic Mechanical Analysis: A Five-Part Webinar Series

Learn the fundamentals and advanced applications of Dynamic Mechanical Analysis (DMA) to confidently characterize viscoelastic material behavior, accurately interpret mechanical properties, and optimize material development and processing performance.

Explore All Webinars
Blue puzzle piece fitting into a white puzzle, symbolizing integration and problem-solving in quality management systems.
Sample Holder for 3-Point-Bending
Sample holder for tension testing, featuring a sturdy design with multiple vertical supports and a central measuring rod.
Sample Holder for Tension
Sample holder for powdery and pasty materials, featuring a sleek design with multiple vertical compartments for testing efficiency.
Sample Holder for Powdery and Pasty Samples
Sample holder for bending, featuring adjustable rods and a sturdy base for precise testing and analysis.
Sample Holder for Bending
Sample holder designed for penetration testing, featuring adjustable supports and a central rod for accurate measurements.
Sample Holder for Penetration
Stainless steel immersion test container with vertical rods for conducting water immersion tests and analysis.
Container for immersion tests
Sample holder for cantilever bending test, featuring a sturdy base and multiple vertical supports for accurate analysis.
Sample Holder for Cantilever Bending
Shear sample holder designed for effective material testing; features multiple supports for secure sample positioning.
Shear Sample Holder

Excellence in Sample Handling

NETZSCH offers a wide variety of sample holders for its DMA 303 Eplexor®. This results in optimal adaptation of the test conditions to the sample size and stiffness, as well as to the application. For example, a different sample holder is needed to measure a thin polymer film versus a stiff material such as a fiber-reinforced composite.

The RFID (Radio Frequency Identification) technology automatically detects the frame and probe employed and selects the correct calibration in the software.

Please accept Marketing Cookies to see that Video.

DMA 303 Eplexor® in summary 

Method

Dynamic Mechanical Analysis (DMA/DMTA) is an essential tool for evaluating the mechanical characteristics of engineering materials, particularly the viscoelastic properties inherent in polymers.

Changes in a material's viscoelastic behavior can be quantified by subjecting it to dynamic forces and deformations, such as variations in temperature, time, frequency, StressStress is defined as a level of force applied on a sample with a well-defined cross section. (Stress = force/area). Samples having a circular or rectangular cross section can be compressed or stretched. Elastic materials like rubber can be stretched up to 5 to 10 times their original length.stress, atmosphere, or a combination thereof.

How Dynamic Mechanical Analysis Enhances Your Product Commitment
Polymers - Crucial Material in Manufacturing 
Polymers offer the advantage of being lightweight and easily adaptable to various shapes through diverse manufacturing techniques. Especially in sectors where plastic components serve pivotal functions, such as automotive, electronics, or medical fields, their performance must align with design specifications. Achieving this necessitates a thorough comprehension of material behavior, spanning from molecular dynamics to tangible mechanical attributes.

Predicting Mechanical Performance - Key to Product Innovation 
Dynamic Mechanical Analysis (DMA) emerges as a highly sensitive analytical approach for scrutinizing material traits throughout the design and manufacturing phases. It facilitates the determination of a broad spectrum of mechanical attributes, encompassing stiffness, elasticity, damping, and viscoelastic characteristics.

Specifications

Temperature Range
-170°C to 800°C
Frequency Range
0.001 Hz to 200 Hz
Force range
1 mN to 50 N
NETZSCH DMA 303 Eplexor device with touchscreen, designed for advanced analytical testing in material characterization.
  • Static deformation: up to 30 mm
  • Highest Sensitivity with 1-nm Resolution
  • Deformation modes:
    • 3-point bending
    • Single/dual cantilever bending
    • Shear
    • Tension
    • Compression/penetration
  • Maximum controlled amplitude: ± 2.5 mm

Software

E-Learning

Become an Expert with our Free E-Learning Courses

All NETZSCH E-Learning Basic Courses are free of charge! The content is created by our laboratory method experts, who share their personal experiences with you. Take advantage of flexible online learning, fully adapted to your training needs!

Please accept Marketing Cookies to see that Video.

Ferrari Formula 1 car in the pit, surrounded by pit crew in red uniforms, preparing for a quick tire change.

Consultancy & Sales

Do you have further questions about the device, the method and would you like to speak to a sales representative?

Service & Support

Do you already have an device and need technical support or spare parts?

Related Devices

  • DMA 503 Eplexor
    DMA 503 Eplexor®
    • Temperature range from -160°C to 500°C
    • Dynamic forces up to ±500N
    • Static forces up to 1500N
  • DMA 503 Eplexor HT
    DMA 503 Eplexor® HT
    • Temperature range from -160°C to 1500°C
    • Dynamic forces up to ±500N
    • Static forces up to 1500N
  • DMA 523 Eplexor
    DMA 523 Eplexor®
    • Temperature range from -160°C to 500°C
    • Dynamic forces up to ±4000N
    • Static forces up to 6000N

Videos

Exciting Innovations for the NETZSCH Dynamic Mechanical Analyzer 303

We are introducing four new features to our dynamic mechanical analyzer. Along with its impressive force range of ±50 N and temperature capability from -170 to +800°C, you can now benefit from a new humidity option for testing under defined conditions, UV light exposure for Curing (Crosslinking Reactions)Literally translated, the term “crosslinking“ means “cross networking”. In the chemical context, it is used for reactions in which molecules are linked together by introducing covalent bonds and forming three-dimensional networks.curing reactions, an integrated USB camera for real-time sample observation, and a TMA mode that combines dynamic mechanical analysis with thermal expansion measurements.

Please accept Marketing Cookies to see that Video.

This is an excerpt of our NETZSCH Tech Talk of December 2024.

Better Understanding of a Material's Mechanical Behavior

When testing the viscoelastic behavior of polymers, the forces applied are critical. From very low to very high forces, Dr. Wiebold Wurpts will give a brief overview of the new developments of our DMA Eplexor® product line.

Please accept Marketing Cookies to see that Video.

This is an excerpt of our NETZSCH Tech Talk 2023.

Please accept Marketing Cookies to see that Video.

KEY NOTE:  Take Control of the Mechanical Behavior of Your Products
AI Overview
An error occurred. Please try again.