Evolved Gas Analysis (EGA) is the perfect tool for characterizing the thermal behavior of organics, inorganics, or polymers in more detail, elucidating the chemistry behind the processes.
The PERSEUS® TGA 309 Libra® is robust and stands out by virtue of its high performance, compactness and attractive price. This instrument integrates the small but powerful FT-IR with the TGA and has the potential to fit into any laboratory – be it in universities or industry, quality assurance or development.
Any existing NETZSCH TG 309 Libra® Supreme and the TG 309 Libra® Select system can be upgraded with the PERSEUS® coupling.
The PERSEUS® TG 309 Libra® can be employed for the following application areas:
- Analysis of Decomposition reactionA decomposition reaction is a thermally induced reaction of a chemical compound forming solid and/or gaseous products. decomposition processes
- Solid-gas reactions
- Compositional analysis
- Evaporation, outgassing
- Detection of volatiles
- Analysis of aging processes
- Desorption behavior

Request a Quote

Affordable Gas Analysis
The unrivaled instrument alliance serves as an innovative coupling technique, even for a narrow budget. It has what it takes to become an integral part of any laboratory and may well become indispensable for future needs.
No Liquid Nitrogen required
The DLaTGS (deuterated L-alanine doped triglycine sulfate) detector operates without the need for liquid nitrogen. This system is thus particularly well-suited for test runs with an autosampler (ASC) or long-term measurements.
Technical Data
Heating of transfer tube
Heating of gas cell
software-controlled
Detector
Gas cell length/volume:
70 mm / 5.8 ml (no mirror inside, beam conforming design)
Spectral range of FT-IR data:
350 cm-1 to 8000 cm-1 KBr windows
Gas cell:
KBr windows, sealing Viton©
To view the technical data of the TG 309 Libra®, please click HERE.

The PERSEUS® coupling interface is distinguished by its exceptional design and user-friendly operation, even with automatic sample changer.
It eliminates the need for a separate transfer line by integrating a heated gas cell directly connected to the furnace's gas outlet through a heated tube. The short gas path's low volume ensures rapid response, which is particularly beneficial when dealing with condensable evolved gases. Moreover, the PERSEUS® is notable for its exceptionally small footprint.
The video shows the fast and straight forward disassembling of the Bruker Alpha II to enable ATR measurements with the same instrument within a few minutes.
Application Literature